MR-Guided Freehand Biopsy of Liver Lesions With Fast Continuous Imaging Using a 1.0-T Open MRI Scanner: Experience in 50 Patients

被引:0
|
作者
Frank Fischbach
Jürgen Bunke
Markus Thormann
Gunnar Gaffke
Kerstin Jungnickel
Jouke Smink
Jens Ricke
机构
[1] Otto von Guericke University,Department of Radiology, Medical School
[2] Philips Healthcare,undefined
关键词
Interventional radiology; Liver biopsy; 1 Tesla; Open MRI; Freehand intervention; Needle artefact;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to assess a new open system with a field-strength of 1.0 T for the feasibility of liver biopsy using the freehand technique with fast continuous imaging. Fifty patients with focal liver lesions measuring 5 to 30 mm in diameter were included in the study. Guidance and monitoring was performed using a 1.0-T open magnetic resonance (MR) scanner (Panorama HFO; Philips Healthcare, Best, The Netherlands). With fast continuous imaging using a T1-weighted (T1W) gradient echo (GRE) sequence after administration of gadolinium (Gd)-EOB-DTPA, the needle was placed into the lesion. An interface for interactive dynamic viewing in two perpendicular planes prevented needle deviations T2-weighted turbo spin echo (TSE) fat-suppressed sequence was added to rule out postinterventional hematoma or biloma. All lesions were visible on the interventional images. Biopsy was technically successful, and solid specimens were obtained in all cases. Forty-six patients showed a histopathologic pattern other than native liver tissue, thus confirming correct position of the needle. Time between determination of the lesion and performance of the control scan was on average 18 min. No major complications were recorded. MR guidance with the new 1-T open system must be considered an attractive alternative for liver punction. An interface for dynamic imaging of needle guidance and T1W-GRE imaging with administration of Gd-EOB-DTPA for contrast enhancement allows the pinpoint puncture of liver lesions.
引用
收藏
页码:188 / 192
页数:4
相关论文
共 25 条
  • [1] MR-Guided Freehand Biopsy of Liver Lesions With Fast Continuous Imaging Using a 1.0-T Open MRI Scanner: Experience in 50 Patients
    Fischbach, Frank
    Bunke, Juergen
    Thormann, Markus
    Gaffke, Gunnar
    Jungnickel, Kerstin
    Smink, Jouke
    Ricke, Jens
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (01) : 188 - 192
  • [2] Real-time MR-guided brain biopsy using 1.0-T open MRI scanner
    Xiangmeng He
    Ming Liu
    Chao Liu
    Jing Fang
    Yujun Xu
    Ligang Wang
    Jianfeng Xiang
    Roberto Blanco Sequeiros
    Chengli Li
    European Radiology, 2019, 29 : 85 - 92
  • [3] Real-time MR-guided brain biopsy using 1.0-T open MRI scanner
    He, Xiangmeng
    Liu, Ming
    Liu, Chao
    Fang, Jing
    Xu, Yujun
    Wang, Ligang
    Xiang, Jianfeng
    Sequeiros, Roberto Blanco
    Li, Chengli
    EUROPEAN RADIOLOGY, 2019, 29 (01) : 85 - 92
  • [4] MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open high-field MRI scanner with respiratory gating
    Ming Liu
    Jie Huang
    Yujun Xu
    Xiangmeng He
    Lei Li
    Yubo Lü
    Qiang Liu
    Roberto Blanco Sequeiros
    Chengli Li
    European Radiology, 2017, 27 : 1459 - 1466
  • [5] MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open high-field MRI scanner with respiratory gating
    Liu, Ming
    Huang, Jie
    Xu, Yujun
    He, Xiangmeng
    Li, Lei
    Lu, Yubo
    Liu, Qiang
    Sequeiros, Roberto Blanco
    Li, Chengli
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1459 - 1466
  • [6] MR-guided Freehand Biopsy of Breast Lesions in a 1.0-T Open MR Imager with a Near-Real-time Interactive Platform: Preliminary Experience
    Fischbach, Frank
    Eggemann, Holm
    Bunke, Juergen
    Wonneberger, Uta
    Ricke, Jens
    Strach, Katharina
    RADIOLOGY, 2012, 265 (02) : 359 - 370
  • [7] Imaging sequences for intraoperative MR-guided laparoscopic liver resection in 1.0-T high field open MRI
    Chopra, S. S.
    Rump, J.
    Schmidt, S. C.
    Streitparth, F.
    Seebauer, C.
    Schumacher, G.
    Van der Voort, I.
    Teichgraeber, U.
    EUROPEAN RADIOLOGY, 2009, 19 (09) : 2191 - 2196
  • [8] Imaging sequences for intraoperative MR-guided laparoscopic liver resection in 1.0-T high field open MRI
    S. S. Chopra
    J. Rump
    S. C. Schmidt
    F. Streitparth
    C. Seebauer
    G. Schumacher
    I. Van der Voort
    U. Teichgräber
    European Radiology, 2009, 19 : 2191 - 2196
  • [9] MR-guided Percutaneous Biopsy of Focal Hepatic Dome Lesions with Free-hand Combined with MR Fluoroscopy Using 1.0-T Open High-field Scanner
    Wang, Ligang
    Liu, Ming
    Liu, Liming
    Zheng, Yanbo
    Xu, Yujun
    He, Xiangmeng
    Li, Peipei
    Li, Chengli
    ANTICANCER RESEARCH, 2017, 37 (08) : 4635 - 4641
  • [10] Real-time MR-guided wire localization of breast lesions by using an open 1.0-T imager: Intitial experience
    Gossmann, Axel
    Bangard, Christopher
    Warm, Mathias
    Schmutzler, Rita K.
    Mallmann, Peter
    Lackner, Klaus-Ju Rgen
    RADIOLOGY, 2008, 247 (02) : 535 - 542