Cuffed oropharyngeal airway and capnometry: Comparison of end-tidal and arterial carbon dioxide pressures

被引:0
|
作者
Kobayashi Y. [1 ]
Seki S. [1 ]
Ichimiya T. [1 ]
Iwasaki H. [1 ]
Namiki A. [1 ]
机构
[1] Department of Anesthesia, Asahikawa City Hospital, Asahikawa 070-8610
关键词
Capnometry; Cuffed oropharyngeal airway; Hypercapnia;
D O I
10.1007/s005400050044
中图分类号
学科分类号
摘要
Purpose. The aim of this study was to investigate the reliability of end-tidal CO2 tension (PETCO2) as a predictor of PaCO2 during anesthesia in patients breathing spontaneously via a cuffed oropharyngeal airway (COPA). Methods. Twenty adult patients scheduled for minor sur gery were included in this study. After propofol injection: an appropriate size of COPA was inserted. Anesthesia was maintained with 60% nitrous oxide in oxygen (total flow rate of 51.min-1) supplemented with propofol infusion. The patients were allowed to breathe spontaneously throughout the procedure. PaCO2 and PETCO2 were simultaneously measured when a steady state of anesthesia was reached. Results. PaCO2 (48.8 ± 5.4 mmHg, range 36.2-58.0 mmHg) was higher than PETCO2 (43.1 ± 4.2 mmHg, range 32-51 mmHg) in all patients. The difference between end-tidal and arterial CO2 tension was 5.7 ± 3.2 mmHg (range 0.5-13.0 mmHg), and was significantly correlated with PaCO2 (P < 0.01). Conclusion. The results of this study suggest that PETCO2 in anesthetized patients breathing spontaneously through a COPA is sometimes unreliable as an indicator of PaCO2 level, and there is some possibility of unexpected hypercapnia.
引用
收藏
页码:136 / 139
页数:3
相关论文
共 50 条
  • [1] Relationship between end-tidal and arterial carbon dioxide partial pressure using a cuffed oropharyngeal airway and a tracheal tube
    Nakata, Y
    Goto, T
    Uezono, S
    Sasaki, F
    Morita, S
    BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (02) : 253 - 254
  • [2] Arterial to end-tidal carbon dioxide tension difference in anaesthetized adults mechanically ventilated via a laryngeal mask or a cuffed oropharyngeal airway
    Casati, A
    Fanelli, G
    Cappelleri, G
    Albertin, A
    Anelati, D
    Magistris, L
    Torri, G
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1999, 16 (08) : 534 - 538
  • [3] COMPARISON OF END-TIDAL AND ARTERIAL CARBON-DIOXIDE MEASUREMENTS DURING ANESTHESIA WITH THE LARYNGEAL MASK AIRWAY
    HICKS, IR
    SONI, NC
    SHEPHARD, JN
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (05) : 734 - 735
  • [4] Comparison of end-tidal and arterial carbon dioxide in infants using laryngeal mask airway and endotracheal tube
    Chhibber, AK
    Fickling, K
    Kolano, JW
    Roberts, WA
    ANESTHESIA AND ANALGESIA, 1997, 84 (01): : 51 - 53
  • [5] End-tidal carbon dioxide and arterial to end-tidal carbon dioxide gradient are associated with mortality in patients with neurological injuries
    Le Gall, Arthur
    Eustache, Gabriel
    Coquet, Alice
    Seguin, Philippe
    Launey, Yoann
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [6] End-tidal sevoflurane concentrations for cuffed oropharyngeal airway (COPA) insertion in the elderly and young adult
    Tanaka, M
    Nishikawa, T
    ANESTHESIA AND ANALGESIA, 1998, 86 (2S):
  • [7] ARTERIAL TO END-TIDAL CARBON-DIOXIDE GRADIENTS
    SOSIS, M
    ANESTHESIA AND ANALGESIA, 1988, 67 (05): : 486 - 486
  • [8] Factors affecting the relationship between arterial and end-tidal carbon dioxide pressures in the anaesthetised horse
    Rainger, J. E.
    Dart, C. M.
    Perkins, N. R.
    AUSTRALIAN VETERINARY JOURNAL, 2010, 88 (1-2) : 13 - 19
  • [9] Difference between arterial and end-tidal carbon dioxide pressures during laparoscopy in paediatric patients
    M. Laffon
    A. Gouchet
    P. Sitbon
    V. Guicheteau
    E. Biyick
    A. Duchalais
    C. Mercier
    Canadian Journal of Anaesthesia, 1998, 45 : 561 - 563
  • [10] Difference between arterial and end-tidal carbon dioxide pressures during laparoscopy in paediatric patients
    Laffon, M
    Gouchet, A
    Sitbon, P
    Guicheteau, V
    Biyick, E
    Duchalais, A
    Mercier, C
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (06): : 561 - 563