The feasibility of halfcycle reconstruction in high heart rates in coronary CT angiography using 320-row CT

被引:0
|
作者
Nobuo Tomizawa
Kodai Yamamoto
Masaaki Akahane
Rumiko Torigoe
Shigeru Kiryu
Kuni Ohtomo
机构
[1] The University of Tokyo,Department of Radiology
[2] Tokyo Metropolitan Regional Office,Toshiba Medical Systems Corporation
[3] The University of Tokyo,Department of Radiology, Institute of Medical Science
关键词
Coronary CT angiography; Multicycle reconstruction; Halfcycle reconstruction; 320-Row CT;
D O I
暂无
中图分类号
学科分类号
摘要
Our aim was to investigate when halfcycle reconstruction (HCR) was feasible in patients who were predicted to have a heart rate over 65 bpm in coronary CT angiography (CTA) using 320-row CT. Seventy-four patients who underwent multiple heart beat scanning were included. The time to reach 230 HU at the ascending aorta during the bolus tracking scan was recorded (T230). HCR image and multicycle reconstruction (MCR) image were reconstructed for each patient. Image quality for each coronary segment was rated on a 3-point scale (3: good, 1: poor). For each patient, we determined that a single beat acquisition was feasible for diagnosis (HCR group) when the number of segments graded score 1 in the HCR image was the same or less than that in the MCR image. Otherwise, we included the patients in the MCR group. HCR group and MCR group included 38 and 36 patients, respectively. Regression analysis showed that body height >1.66 m (odds ratio (OR), 5.74; CI 1.59–25.6; p < 0.007), T230 >16 s (OR 3.11; CI 1.07–9.58; p = 0.04), and heart rate ≤72 bpm (OR 3.18; CI 1.11–9.49; p = 0.03) were related with the HCR group. When all three criteria were fulfilled, the calculated probability that MCR would improve image quality was only 7 %. When the heart rate is ≤72 bpm, single heart beat acquisition is feasible for patients with body height >1.66 m and T230 > 16 s in coronary CTA using 320-row CT.
引用
收藏
页码:907 / 911
页数:4
相关论文
共 50 条
  • [1] The feasibility of halfcycle reconstruction in high heart rates in coronary CT angiography using 320-row CT
    Tomizawa, Nobuo
    Yamamoto, Kodai
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (04): : 907 - 911
  • [2] The effect of heart rate on coronary plaque measurements in 320-row coronary CT angiography
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Sakabe, Daisuke
    Oda, Seitaro
    Nakaura, Takeshi
    Yuki, Hideaki
    Nagayama, Yasunori
    Hirata, Kenichiro
    Iyama, Yuji
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (12): : 1977 - 1985
  • [3] The effect of heart rate on coronary plaque measurements in 320-row coronary CT angiography
    Masafumi Kidoh
    Daisuke Utsunomiya
    Yoshinori Funama
    Daisuke Sakabe
    Seitaro Oda
    Takeshi Nakaura
    Hideaki Yuki
    Yasunori Nagayama
    Kenichiro Hirata
    Yuji Iyama
    Tomohiro Namimoto
    Yasuyuki Yamashita
    The International Journal of Cardiovascular Imaging, 2018, 34 : 1977 - 1985
  • [4] Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT
    Tomizawa, Nobuo
    Kanno, Shigeaki
    Maeda, Eriko
    Akahane, Masaaki
    Torigoe, Rumiko
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (07) : 391 - 396
  • [5] Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT
    Nobuo Tomizawa
    Shigeaki Kanno
    Eriko Maeda
    Masaaki Akahane
    Rumiko Torigoe
    Kuni Ohtomo
    Japanese Journal of Radiology, 2014, 32 : 391 - 396
  • [6] Evaluation of CT coronary artery angiography with 320-row detector CT in a high-risk population
    Gang, S.
    Min, L.
    Li, L.
    Guo-Ying, L.
    Lin, X.
    Qun, J.
    Hua, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013): : 562 - 570
  • [7] Coronary computed tomography angiography and endocardial leads - Image quality in 320-row CT using iterative reconstruction
    Garmer, Marietta
    Bonsels, Marc
    Metz, Frauke
    Klein-Wiele, Oliver
    Brandts, Bodo
    Groenemeyer, Dietrich
    CLINICAL IMAGING, 2018, 50 : 157 - 163
  • [8] Diagnostic accuracy of 320-row coronary CT angiography in the assessment of coronary in-stent restenosis
    Kishi, S.
    Tanabe, K.
    Yachi, S.
    Otsuka, T.
    Nakajima, Y.
    Taniwaki, M.
    Tanimoto, S.
    Aoki, J.
    Nakajima, H.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 524 - 524
  • [9] Radiation dose for 320-row dose-modulated dynamic coronary CT angiography
    Izoe, Yukako
    Nagao, Michinobu
    Tokai, Mei
    Hashimoto, Hiroyuki
    Tanaka, Isao
    Chida, Koichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 307 - 312
  • [10] Effect of saline flush on enhancement of proximal and distal segments using 320-row coronary CT angiography
    Tomizawa, Nobuo
    Suzuki, Fumio
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : 1255 - 1259