Enhanced sensitivity of surface plasmon resonance phase-interrogation biosensor by using oblique deposited silver nanorods

被引:0
|
作者
Hung-Yi Chung
Chih-Chia Chen
Pin Chieh Wu
Ming Lun Tseng
Wen-Chi Lin
Chih-Wei Chen
Hai-Pang Chiang
机构
[1] Academia Sinica,Research Center for Applied Sciences
[2] National Taiwan Ocean University,Institute of Optoelectronic Sciences
[3] National Taiwan University,Graduate Institute of Applied Physics
[4] Academia Sinica,Institute of Physics
关键词
Surface plasmons; Biosensor; Nanorods; Oblique angle deposition; Phase interrogation;
D O I
暂无
中图分类号
学科分类号
摘要
Sensitivity of surface plasmon resonance phase-interrogation biosensor is demonstrated to be enhanced by oblique deposited silver nanorods. Silver nanorods are thermally deposited on silver nanothin film by oblique angle deposition (OAD). The length of the nanorods can be tuned by controlling the deposition parameters of thermal deposition. By measuring the phase difference between the p and s waves of surface plasmon resonance heterodyne interferometer with different wavelength of incident light, we have demonstrated that maximum sensitivity of glucose detection down to 7.1 × 10-8 refractive index units could be achieved with optimal deposition parameters of silver nanorods.
引用
收藏
相关论文
共 50 条
  • [1] Enhanced sensitivity of surface plasmon resonance phase-interrogation biosensor by using oblique deposited silver nanorods
    Chung, Hung-Yi
    Chen, Chih-Chia
    Wu, Pin Chieh
    Tseng, Ming Lun
    Lin, Wen-Chi
    Chen, Chih-Wei
    Chiang, Hai-Pang
    NANOSCALE RESEARCH LETTERS, 2014, 9
  • [2] Enhanced Sensitivity of Surface Plasmon Resonance Phase-Interrogation Biosensor by Using Silver Nanoparticles
    Peng, Tzu-Cheih
    Lin, Wen-Chi
    Chen, Chih-Wei
    Tsai, Din Ping
    Chiang, Hai-Pang
    PLASMONICS, 2011, 6 (01) : 29 - 34
  • [3] Enhanced Sensitivity of Surface Plasmon Resonance Phase-Interrogation Biosensor by Using Silver Nanoparticles
    Tzu-Cheih Peng
    Wen-Chi Lin
    Chih-Wei Chen
    Din Ping Tsai
    Hai-Pang Chiang
    Plasmonics, 2011, 6 : 29 - 34
  • [4] Enhanced sensitivity of localized surface plasmon resonance biosensor by phase interrogation
    Li, Chung-Tien
    Chen, How-Foo
    Yen, Ta-Jen
    OPTICAL SENSORS 2011 AND PHOTONIC CRYSTAL FIBERS V, 2011, 8073
  • [5] A surface acoustic wave (SAW)-enhanced grating-coupling phase-interrogation surface plasmon resonance (SPR) microfluidic biosensor
    Sonato, A.
    Agostini, M.
    Ruffato, G.
    Gazzola, E.
    Liuni, D.
    Greco, G.
    Travagliati, M.
    Cecchini, M.
    Romanato, F.
    LAB ON A CHIP, 2016, 16 (07) : 1224 - 1233
  • [6] Improved sensitivity of wavelength-modulated surface plasmon resonance biosensor using gold nanorods
    Hao, Peng
    Wu, Yihui
    Li, Fengjie
    APPLIED OPTICS, 2011, 50 (28) : 5555 - 5558
  • [7] Enhanced sensitivity of a surface plasmon resonance biosensor using hyperbolic metamaterial and monolayer graphene
    Gao, Jinjuan
    Zu, Qun
    Xu, Shicai
    Yang, Wen
    Feng, Jingwen
    Liu, Runcheng
    Zha, Zhipeng
    Peng, Qianqian
    Yue, Weiwei
    Huo, Yanyan
    Jiang, Shouzhen
    Fan, Xiuwei
    OPTICS EXPRESS, 2021, 29 (26): : 43766 - 43777
  • [8] Surface plasmon resonance biosensor incorporated in a Michelson interferometer with enhanced sensitivity
    Yuan, Wu
    Ho, H. P.
    Wong, C. L.
    Kong, S. K.
    Lin, Chinlon
    IEEE SENSORS JOURNAL, 2007, 7 (1-2) : 70 - 73
  • [9] A portable surface plasmon resonance biosensor capable of phase interrogation in a large dynamic range
    Chen, How-Foo
    Chuang, Hsin-Yuan
    Chen, Chih-Hang
    Chang, Yun-Hsiang
    BIOSENSING AND NANOMEDICINE VII, 2014, 9166
  • [10] Surface plasmon resonance waveguide biosensor by bipolarization wavelength interrogation
    Wang, TJ
    Tu, CW
    Liu, FK
    Chen, HL
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2004, 16 (07) : 1715 - 1717