An experimental and theoretical study of the operation of a model of a normal ultrasonic transducer for various acoustic loads has been performed. It has been established that, in the design of the transducer under study, a relatively thick adhesive layer between the piezoelectric plate and the wear plate abruptly reduces the operating (effective) signal frequency in the case of an immersion load. An equation for estimating the effective frequency for a transducer model has been obtained with allowance for the characteristics of such a layer.
引用
收藏
页码:353 / 364
页数:11
相关论文
共 50 条
  • [1] Operation of a model of a normal ultrasonic transducer for immersion and conventional inspection techniques
    Danilov, V. N.
    Artem'ev, S. A.
    Zakharov, A. F.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2007, 43 (06) : 353 - 364
  • [2] A model for transient ultrasonic field in solid generated by a transducer in immersion
    Jian, X.
    Weight, J. P.
    Grattan, K. T. V.
    Dixon, S.
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 133 (02) : 439 - 446
  • [3] ULTRASONIC IMMERSION INSPECTION OF CONTOURED OBJECTS
    WOLTERS, WJ
    MATERIALS EVALUATION, 1982, 40 (03) : A11 - A11
  • [4] TRANSDUCER FOR ULTRASONIC INSPECTION OF DRILL PIPE
    DZHERIKI, GK
    SHCHERBAKOV, VY
    SOLOVEV, IY
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1982, 18 (12): : 967 - 968
  • [5] GUIDELINES FOR IMMERSION ULTRASONIC INSPECTION OF PIPE AND TUBING
    SHEPLEY, WI
    MATERIALS EVALUATION, 1972, 30 (09) : A40 - &
  • [7] Micromachined capacitive ultrasonic immersion transducer for medical imaging
    Jin, XC
    Khuri-Yakub, BT
    Degertekin, FL
    Ladabaum, I
    Calmes, S
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 779 - 782
  • [8] An absolute method for determination of misalignment of an immersion ultrasonic transducer
    Narayanan, M. M.
    Singh, Narender
    Kumar, Anish
    Rao, C. Babu
    Jayakumar, T.
    ULTRASONICS, 2014, 54 (08) : 2081 - 2089
  • [9] INCREASING THE RELIABILITY OF IMMERSION ULTRASONIC INSPECTION OF THE NONMACHINED SURFACE
    APAKHOV, MI
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1987, 23 (09): : 589 - 593
  • [10] Selection of the parameters of a probe during immersion ultrasonic inspection
    V. N. Danilov
    Russian Journal of Nondestructive Testing, 2007, 43 : 336 - 343