Low-temperature technique of thin silicon ion implanted epitaxial detectors

被引:0
|
作者
A. J. Kordyasz
N. Le Neindre
M. Parlog
G. Casini
R. Bougault
G. Poggi
A. Bednarek
M. Kowalczyk
O. Lopez
Y. Merrer
E. Vient
J. D. Frankland
E. Bonnet
A. Chbihi
D. Gruyer
B. Borderie
G. Ademard
P. Edelbruck
M. F. Rivet
F. Salomon
M. Bini
S. Valdré
E. Scarlini
G. Pasquali
G. Pastore
S. Piantelli
A. Stefanini
A. Olmi
S. Barlini
A. Boiano
E. Rosato
A. Meoli
A. Ordine
G. Spadaccini
G. Tortone
M. Vigilante
E. Vanzanella
M. Bruno
S. Serra
L. Morelli
M. Guerzoni
R. Alba
D. Santonocito
C. Maiolino
M. Cinausero
F. Gramegna
T. Marchi
T. Kozik
P. Kulig
T. Twaróg
机构
[1] Warsaw University,Heavy Ion Laboratory
[2] Université de Caen,LPC, IN2P3
[3] “Horia Hulubei” National Institute of Physics and Nuclear Engineering (IFIN-HH),CNRS, ENSICAEN
[4] INFN and Università di Firenze,Institute of Experimental Physics
[5] University of Warsaw,GANIL
[6] CEA and IN2P3-CNRS,Institut de Physique Nucléaire
[7] IN2P3-CNRS,INFN and Dipartimento di Scienze Fisiche
[8] Università di Napoli “Federico II”,LNS
[9] INFN and Università di Bologna,Silesian University
[10] INFN and Università di Catania,Warsaw University of Technology
[11] INFN LNL Legnaro,Institute of Mikromechanics and Photonics, Department of Design of Precision Devices
[12] Jagiellonian University,undefined
[13] University of Silesia,undefined
[14] Institute of Electronic Materials Technology,undefined
[15] Faculty of Physics,undefined
[16] Warsaw University of Technology,undefined
[17] Faculty of Mechatronics,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A new technique of large-area thin ion implanted silicon detectors has been developed within the R&D performed by the FAZIA Collaboration. The essence of the technique is the application of a low-temperature baking process instead of high-temperature annealing. This thermal treatment is performed after B+ ion implantation and Al evaporation of detector contacts, made by using a single adjusted Al mask. Extremely thin silicon pads can be therefore obtained. The thickness distribution along the X and Y directions was measured for a prototype chip by the energy loss of α-particles from 241Am (〈Eα〉 = 5.5 MeV). Preliminary tests on the first thin detector (area ≈ 20 × 20 mm2) were performed at the INFN-LNS cyclotron in Catania (Italy) using products emitted in the heavy-ion reaction 84Kr (E = 35 A MeV) + 112Sn. The ΔE − E ion identification plot was obtained using a telescope consisting of our thin ΔE detector (21 μm thick) followed by a typical FAZIA 510 μm E detector of the same active area. The charge distribution of measured ions is presented together with a quantitative evaluation of the quality of the Z resolution. The threshold is lower than 2 A MeV depending on the ion charge.
引用
收藏
相关论文
共 50 条
  • [1] Low-temperature technique of thin silicon ion implanted epitaxial detectors
    Kordyasz, A. J.
    Le Neindre, N.
    Parlog, M.
    Casini, G.
    Bougault, R.
    Poggi, G.
    Bednarek, A.
    Kowalczyk, M.
    Lopez, O.
    Merrer, Y.
    Vient, E.
    Frankland, J. D.
    Bonnet, E.
    Chbihi, A.
    Gruyer, D.
    Borderie, B.
    Ademard, G.
    Edelbruck, P.
    Rivet, M. F.
    Salomon, F.
    Bini, M.
    Valdre, S.
    Scarlini, E.
    Pasquali, G.
    Pastore, G.
    Piantelli, S.
    Stefanini, A.
    Olmi, A.
    Barlini, S.
    Boiano, A.
    Rosato, E.
    Meoli, A.
    Ordine, A.
    Spadaccini, G.
    Tortone, G.
    Vigilante, M.
    Vanzanella, E.
    Bruno, M.
    Serra, S.
    Morelli, L.
    Guerzoni, M.
    Alba, R.
    Santonocito, D.
    Maiolino, C.
    Cinausero, M.
    Gramegna, F.
    Marchi, T.
    Kozik, T.
    Kulig, P.
    Twarog, T.
    EUROPEAN PHYSICAL JOURNAL A, 2015, 51 (02):
  • [2] FIRST TESTS OF SUPERTHIN, ION-IMPLANTED SILICON STRIP DETECTORS PRODUCED BY LOW-TEMPERATURE TECHNIQUE
    Kordyasz, A. J.
    Kownacki, J.
    Kordyasz, L.
    Konop, M.
    Bednarek, A.
    Kowalczyk, M.
    Tarasiuk, J.
    Kisielinski, M.
    Kozik, T.
    Piasecki, E.
    Sibczynski, P.
    Stolarz, A.
    Kowalska, J.
    Tucholski, A.
    Srebrny, J.
    Wolinska-Cichocka, M.
    Napiorkowski, P.
    Sarnecki, J.
    Lipinski, D.
    Wodzinska, H.
    Teodorczyk, M.
    Gajewski, M.
    Zagojski, A.
    Krzyzak, K.
    ACTA PHYSICA POLONICA B, 2016, 47 (03): : 797 - 802
  • [3] LOW-TEMPERATURE CHARACTERISTICS OF ION-IMPLANTED SILICON POSITION-SENSITIVE DETECTORS
    ELAD, E
    SAREEN, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 75 - 84
  • [4] LOW-TEMPERATURE EPITAXIAL REGROWTH OF ION-IMPLANTED GAAS
    GRIMALDI, MG
    PAINE, BM
    NICOLET, MA
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1980, 127 (08) : C384 - C384
  • [5] CONDUCTION AT LOW-TEMPERATURE IN ION-IMPLANTED SILICON
    BOURGOIN, JC
    FROSSATI, G
    RAVEX, A
    THOULOUZE, D
    VANDORPE, M
    WAKSMANN, B
    PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 1979, 92 (02): : 585 - 594
  • [6] LOW-TEMPERATURE EPITAXIAL REGROWTH OF ION-IMPLANTED AMORPHOUS GAAS
    WILLIAMS, JS
    AUSTIN, MW
    APPLIED PHYSICS LETTERS, 1980, 36 (12) : 994 - 996
  • [7] Low-temperature photoluminescence of hydrogen Ion and plasma implanted silicon and porous silicon
    Chu, P.K. (paul.chu@cityu.edu.hk), 1600, American Institute of Physics Inc. (96):
  • [8] Low-temperature photoluminescence of hydrogen ion and plasma implanted silicon and porous silicon
    An, ZH
    Fu, RKY
    Li, WL
    Chen, P
    Chu, PK
    Li, KF
    Luo, L
    Tam, HL
    Cheah, KW
    Lin, CL
    JOURNAL OF APPLIED PHYSICS, 2004, 96 (01) : 248 - 251
  • [9] Fabrication and Characterization of Boron-Implanted Silicon Superconducting Thin Films on SOI Substrates for Low-Temperature Detectors
    Aliane, A.
    Dussopt, L.
    Kerdiles, S.
    Kaya, H.
    Acosta-Alba, P.
    Bernier, N.
    Papon, A. -M.
    Martinez, E.
    Veillerot, M.
    Lefloch, F.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2024, 216 (1-2) : 185 - 194
  • [10] INVESTIGATION OF LOW-TEMPERATURE EPITAXIAL REGROWTH OF ION-IMPLANTED AMORPHOUS GAAS
    HEROLD, J
    BARTSCH, H
    WESCH, W
    GOTZ, G
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1989, 111 (01): : 59 - 70