Use of Tissue Plasminogen Activator for Femoral Artery Thrombosis Following Transcatheter Coil Occlusion of Patent Ductus Arteriosus

被引:0
|
作者
K. M. Carlson
J. M. Rutledge
B. R. Parker
R. G. Grifka
机构
[1] Texas Children’s Hospital,Lillie Frank Abercrombie Section of Cardiology and Department of Diagnostic Imaging
[2] Baylor College of Medicine,Department of Diagnostic Imaging
[3] Texas Children’s Hospital,undefined
[4] Baylor College of Medicine,undefined
[5] 6621 Fannin,undefined
[6] MC 19345-C,undefined
来源
Pediatric Cardiology | 2005年 / 26卷
关键词
Thrombosis; Patent ductus arteriosus; Tissue plasminogen activator;
D O I
暂无
中图分类号
学科分类号
摘要
Femoral artery thrombosis is an uncommon but potentially serious complication following pediatric cardiac catheterization. Management options include heparin infusion, thrombolytic therapy, and surgical thrombectomy. The use of thrombolytic agents following coil occlusion of shunts, collaterals, and patent ductus arteriosus (PDA) may be successful in resolving the femoral arterial thrombosis but may also reopen the device-occluded vessel. We report the successful use of tissue plasminogen activator for management of femoral artery thrombosis in a child following transcatheter PDA coil occlusion in which the PDA remained occluded.
引用
收藏
页码:83 / 86
页数:3
相关论文
共 50 条
  • [1] Use of tissue plasminogen activator for femoral artery thrombosis following transcatheter coil occlusion of patent ductus arteriosus
    Carlson, KM
    Rutledge, JM
    Parker, BR
    Grifka, RG
    PEDIATRIC CARDIOLOGY, 2005, 26 (01) : 83 - 86
  • [2] Risk of endocarditis following transcatheter coil occlusion of the patent ductus arteriosus
    Vincent, JA
    Turner, DR
    Hennis, P
    Forbes, TJ
    Asmar, BI
    Rabah, R
    Pebbles, K
    CIRCULATION, 2000, 102 (18) : 830 - 830
  • [3] Transcatheter occlusion of the patent ductus arteriosus Use of the retrievable coil device
    Johnston, TA
    Stern, HJ
    O'Laughlin, MP
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 1999, 46 (04) : 434 - 437
  • [4] TRANSCATHETER COIL OCCLUSION OF PATENT DUCTUS-ARTERIOSUS
    FEDDERLY, RT
    LLOYD, TR
    MENDELSOHN, AM
    SANDHU, SK
    LUDOMIRSKY, A
    BEEKMAN, RH
    CIRCULATION, 1993, 88 (04) : 389 - 389
  • [5] Transcatheter occlusion of patent ductus arteriosus using coil embolization
    Jacob, JLB
    Coelho, MWC
    Machado, NCS
    Garzon, SAC
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1997, 60 (02) : 133 - 138
  • [6] Coil occlusion of patent ductus arteriosus
    Berdjis, F
    Moore, JW
    PROGRESS IN PEDIATRIC CARDIOLOGY, 1996, 6 (02) : 137 - 147
  • [7] Giant aneurysm following coil occlusion of patent ductus arteriosus
    Marasini, M
    Rimini, A
    Zannini, L
    Pongiglione, G
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 50 (02) : 186 - 189
  • [8] Coarctation of the aorta following coil occlusion of a patent ductus arteriosus
    Moore, JD
    Shim, D
    Mendelsohn, AM
    Kimball, TR
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 43 (01): : 60 - 62
  • [9] Changes in coil morphology following transcatheter coil occlusion of the patent ductus arteriosus using a modified snare technique
    Dobrolet, NC
    Ettedgui, JA
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (04) : 504 - 509
  • [10] Which method to use for transcatheter occlusion of patent ductus arteriosus?
    Rao, PS
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 39 (01): : 49 - 51