Simultaneous quantitation of sphingoid bases and their phosphates in biological samples by liquid chromatography/electrospray ionization tandem mass spectrometry

被引:0
|
作者
Daisuke Saigusa
Kanako Shiba
Asuka Inoue
Kotaro Hama
Michiyo Okutani
Nagisa Iida
Masayoshi Saito
Kaori Suzuki
Tohru Kaneko
Naoto Suzuki
Hiroaki Yamaguchi
Nariyasu Mano
Junichi Goto
Takanori Hishinuma
Junken Aoki
Yoshihisa Tomioka
机构
[1] Tohoku University,Laboratory of Oncology, Pharmacy Practice and Sciences, Graduate School of Pharmaceutical Sciences
[2] Tohoku University,Department of Molecular and Cellular Biochemistry, Graduate School of Pharmaceutical Sciences
[3] Tohoku University,Laboratory of Pharmacotherapy, Graduate School of Pharmaceutical Sciences
[4] Tohoku University Hospital,Department of Pharmaceutical Sciences
来源
关键词
Sphingoid; Sphingoid phosphate; LC/MS/MS; Simultaneous quantitation; Tissue; Plasma;
D O I
暂无
中图分类号
学科分类号
摘要
We developed a liquid chromatography/electrospray ionization tandem mass spectrometry method for the simultaneous quantitative determination of C18 sphingosine (Sph), C18 dihydrosphingosine (dhSph), C18 phytosphingosine (pSph), C18 sphingosine-1-phosphate (S1P), C18 dihydrosphingosine-1-phosphate (dhS1P), and C18 phytosphingosine-1-phosphate (pS1P). Samples were prepared by simple methanol deproteinization and analyzed in selected reaction monitoring modes. No peak tailing was observed on the chromatograms using a Capcell Pak ACR column (1.5 mm i.d. × 250 mm, 3 μm, Shiseido). The calibration curves of the sphingoids showed good linearity (r > 0.996) over the range of 0.050–5.00 pmol per injection. The accuracy and precision of this method were demonstrated using four representative biological samples (serum, brain, liver, and spleen) from mice that contained known amounts of the sphingoids. Samples of mice tissue such as plasma, brain, eye, testis, liver, kidney, lung, spleen, lymph node, and thymus were examined for their Sph, dhSph, pSph, S1P, dhS1P, and pS1P composition. The results confirmed the usefulness of this method for the physiological and pathological analysis of the composition of important sphingoids.
引用
收藏
页码:1897 / 1905
页数:8
相关论文
共 50 条
  • [1] Simultaneous quantitation of sphingoid bases and their phosphates in biological samples by liquid chromatography/electrospray ionization tandem mass spectrometry
    Saigusa, Daisuke
    Shiba, Kanako
    Inoue, Asuka
    Hama, Kotaro
    Okutani, Michiyo
    Iida, Nagisa
    Saito, Masayoshi
    Suzuki, Kaori
    Kaneko, Tohru
    Suzuki, Naoto
    Yamaguchi, Hiroaki
    Mano, Nariyasu
    Goto, Junichi
    Hishinuma, Takanori
    Aoki, Junken
    Tomioka, Yoshihisa
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (07) : 1897 - 1905
  • [2] Quantitation of glutathione by liquid chromatography/positive electrospray ionization tandem mass spectrometry
    Zhang, Fagen
    Bartels, Michael J.
    Geter, David R.
    Jeong, Yo-Chan
    Schisler, Melissa R.
    Wood, Amanda J.
    Kan, Lynn
    Gollapudi, B. Bhaskar
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (22) : 3608 - 3614
  • [3] Quantification of ceramide species in biological samples by liquid chromatography electrospray ionization tandem mass spectrometry
    Kasumov, Takhar
    Huang, Hazel
    Chung, Yoon-Mi
    Zhang, Renliang
    McCullough, Arthur J.
    Kirwan, John P.
    ANALYTICAL BIOCHEMISTRY, 2010, 401 (01) : 154 - 161
  • [4] Identification and quantitation of despropionyl-bezitramide in postmortem samples by liquid chromatography coupled to electrospray ionization tandem mass spectrometry
    De Baere, SM
    Lambert, WE
    Esmans, EL
    De Leenheer, AP
    ANALYTICAL CHEMISTRY, 1999, 71 (14) : 2908 - 2914
  • [5] Microcolumn liquid chromatography electrospray ionization tandem mass spectrometry - Analysis of immunological samples
    McCormack, AL
    Eng, JK
    DeRoos, PC
    Rudensky, AY
    Yates, JR
    BIOCHEMICAL AND BIOTECHNOLOGICAL APPLICATIONS OF ELECTROSPRAY IONIZATION MASS SPECTROMETRY, 1996, 619 : 207 - 225
  • [6] Quantitation of tadalafil in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionization
    Ramakrishna, NVS
    Vishwottam, KN
    Puran, S
    Koteshwara, M
    Manoj, S
    Santosh, M
    Chidambara, J
    Wishu, S
    Sumatha, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 243 - 249
  • [7] Forensic toxicological determination of surfactant by liquid chromatography/electrospray ionization mass spectrometry and liquid chromatography/electrospray ionization tandem mass spectrometry
    Nishikawa, M
    Katagi, M
    Miki, A
    Tsuchihashi, H
    JOURNAL OF HEALTH SCIENCE, 2003, 49 (02) : 138 - 148
  • [8] Quantitation of cyclic nucleotides in biological samples by negative electrospray tandem mass spectrometry coupled to ion suppression liquid chromatography
    Witters, E
    Roef, L
    Newton, RP
    VanDongen, W
    Esmans, EL
    VanOnckelen, HA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (02) : 225 - 231
  • [9] Liquid chromatography-electrospray ionization mass spectrometry for the simultaneous quantitation of collagen and elastin crosslinks
    Naffa, Rafea
    Holmes, Geoff
    Ahn, Meekyung
    Harding, David
    Norris, Gillian
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1478 : 60 - 67
  • [10] Electrospray ionization mass spectrometry of tetrodotoxin and its analogs: Liquid chromatography/mass spectrometry, tandem mass spectrometry, and liquid chromatography/tandem mass spectrometry
    Shoji, Y
    Yotsu-Yamashita, M
    Miyazawa, T
    Yasumoto, T
    ANALYTICAL BIOCHEMISTRY, 2001, 290 (01) : 10 - 17