摘要
The starting time of a large-rated variable speed pumped storage unit (PSU) operating in pumping mode is crucial in the power balancing scenario in a modern power system as it defines the transition period from generation to pumping modes and vice versa, which determines the stability of the power system. Typically, doubly fed induction machines (DFIM) are preferred in large-rated variable speed PSUs (> 100 MW) as they ensure variable speed operation through partial-rated power converters. The start of DFIM in pumping mode is challenging, and it is ensured through rotor side power converters. DFIM is typically started by short-circuiting the stator windings and supplying power to the rotor windings via power converters. The conventional starting method leads to more starting time and power consumption due to the saturation of the iron core in the earlier speed range because of the higher magnetizing inductance seen from the rotor side. This paper proposed an improved starting method in which the machine's magnetization current is supplied via stator windings and acceleration current is supplied via rotor windings. The proposed method is based on the field-oriented vector control method, and it significantly reduces the starting time and power consumption compared to the conventional starting method. The proposed method is validated through a 306 MVA DFIM-fed variable speed PSU, and results show that the improved starting method reduces the starting time and power consumption by 27.5 and 37.2%, respectively, as compared to the conventional starting method. This reduced starting time is preferred by the grid authorities as it improves the stability of the power system. Furthermore, experimental results are validated in the laboratory with a scaled-down unit of 7.5 kW DFIM.
引用
收藏
页码:615 / 629
页数:14
相关论文
共 25 条
  • [1] Improved start-up strategy for a doubly fed induction machine fed large rated variable speed pumped storage unit in pumping mode operation
    Malathy, N.
    Sukhi, Y.
    [J]. ELECTRICAL ENGINEERING, 2024, 106 (01) : 615 - 629
  • [2] Rotor short-circuited start-up strategy for a doubly fed induction machine-fed large-rated variable-speed pumped storage unit operating in pumping mode
    Narayanasamy, Malathy
    Sukhi, Y.
    [J]. JOURNAL OF POWER ELECTRONICS, 2023, 23 (11) : 1733 - 1744
  • [3] Rotor short-circuited start-up strategy for a doubly fed induction machine-fed large-rated variable-speed pumped storage unit operating in pumping mode
    Malathy Narayanasamy
    Y. Sukhi
    [J]. Journal of Power Electronics, 2023, 23 : 1733 - 1744
  • [4] Modeling and Transient Response Analysis of Doubly-Fed Variable Speed Pumped Storage Unit in Pumping Mode
    Chen, Yahong
    Xu, Wei
    Liu, Yi
    Bao, Zhen
    Mao, Zhixin
    Rashad, Essam M.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (10) : 9935 - 9947
  • [5] Energy Saving Start-up Strategy of Pumped Storage Power Plant Equipped with Doubly-Fed Asynchronous Machine
    Singh, R. Raja
    Chelliah, Thanga Raj
    [J]. PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [6] An Energy-Efficient Start-Up Strategy for Large Variable Speed Hydro Pump Turbine Equipped with Doubly Fed Asynchronous Machine
    Singh, Rassiah Raja
    Baranidharan, Manickavel
    Subramaniam, Umashankar
    Bhaskar, Mahajan Sagar
    Rangarajan, Shriram S.
    Abdelsalam, Hany A.
    Collins, Edward Randolph
    Senjyu, Tomonobu
    [J]. ENERGIES, 2022, 15 (09)
  • [7] Grid-Connection Control of Doubly Fed Variable Speed Pumped Storage Unit
    Gong, Guoxian
    Lv, Jingliang
    Jiang, Xinjian
    Sun, Xudong
    [J]. 2021 5TH INTERNATIONAL CONFERENCE ON GREEN ENERGY AND APPLICATIONS (ICGEA 2021), 2021, : 52 - 57
  • [8] Control Reconfiguration Strategy for Doubly Fed Induction Machine Pumped Storage Unit under Balanced Grid Faults
    Damdoum, A.
    Slama-Belkhodja, I.
    Debbou, M.
    Pietrzak-David, M.
    [J]. 2014 INTERNATIONAL CONFERENCE ON ELECTRICAL SCIENCES AND TECHNOLOGIES IN MAGHREB (CISTEM), 2014,
  • [9] Rotating speed pulling-back control and adaptive strategy of doubly-fed variable speed pumped storage unit
    Gao, Chunyang
    Yu, Xiangyang
    Nan, Haipeng
    Guo, Pengcheng
    Fan, Guoliang
    Meng, Zhijie
    Ge, Ye
    Cai, Qingsen
    [J]. RENEWABLE ENERGY, 2024, 232
  • [10] Dynamic Analysis of Start-up Strategies of AC Excited Double Fed Induction Machine for Pumped Storage Power Plant
    Saiju, Rajesh
    Koutnik, Jiri
    Krueger, Klaus
    [J]. EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 294 - 301