123I-MIBG myocardial scintigraphy in diabetic patients: Relationship with 201Tl uptake and cardiac autonomic function

被引:0
|
作者
Nagamachi S. [1 ]
Jinnouchi S. [1 ]
Kurose T. [1 ]
Ohnishi T. [1 ]
Flores II L.G. [1 ]
Nakahara H. [1 ]
Futami S. [1 ]
Tamura S. [1 ]
Matsukura S. [1 ]
机构
[1] Department of Radiology, Miyazaki Medical College, Miyazaki 889-1692, Kihara 5200, Kiyotakecho
关键词
!sup]123[!/sup]I-MIBG myocardial scintigraphy; Cardiac autonomic neuropathy; Diabetic myocardial damage; NIDDM;
D O I
10.1007/BF03164921
中图分类号
学科分类号
摘要
Purpose: To investigate the influence of diabetic myocardial damage (suspected myocardial damage; SMD) diagnosed by 201Tl-SPECT and diabetic cardiac autonomic neuropathy (AN) on myocardial MIBG uptake in patients with non-insulin-dependent diabetes mellitus (NIDDM). Subjects and Methods: Eighty-seven diabetic patients divided into four subgroups: 23 with SMD (+) AN (+); 19 with SMD (+) AN (-); 27 with SMD (-) AN (+); 18 with SMD (-) AN (- ), and 10 controls were studied. Both planar and SPECT images were taken at 30 minutes (early) and 3 hours (delayed) after 123I-MIBG injection. The heart to mediastinum uptake ratio (H/M) and washout ratio of 123I-MIBG (WR) were obtained from both planar images. On SPECT images, the total uptake score (TUS) was obtained by the 5 point score method by dividing the myocardium into 20 segments on visual analysis. Similarly, the difference between the 201Tl image and the 123I-MIBG image in TUS was taken as the difference in the total uptake score (ΔTUS) representing cardiac sympathetic denervation without SMD. Results: On both early and delayed planar images, the mean H/M value in the subgroups of diabetic patients was significantly lower in the SMD (+) AN (+) group than in the control group, but among those subgroups, there was statistically significant difference between the SMD (+) AN (+) and SMD (-) AN (-) groups only on the delayed images. Regarding the WR value, there was no statistically significant difference among subjects. On SPECT image analysis, the diabetic subgroup with AN or SMD had statistically significant lower values for TUS than those of the control group. Among diabetics, there was a statistically significant differences between SMD [+] AN [+] and SMD [-] AN [-] on both early and delayed images. Similarly, the SMD [+] AN [-] group also had significantly lower values than those of SMD [- ] AN [-] on early images. Regarding ΔTUS, there was a statistically significant differences between AN [+] subgroups and controls. Similarly, the mean value for ΔTUS was much higher in AN [+] subgroups than in AN [-] subgroups with or without SMD in diabetes mellitus. Conclusion: 123I-MIBG myocardial uptake is affected by both SMD and cardiac autonomic neuropathy. Based on the finding that ΔTUS was much higher in AN [+] subgroups and there was no statistically significant difference between SMD [+] AN [+] and SMD [- ] AN [+] subgroups, a decrease in myocardial 123I-MIBG uptake might progress independently of SMD.
引用
收藏
页码:323 / 331
页数:8
相关论文
共 50 条
  • [1] Clinical evaluation of simultaneous 123I-MIBG/201Tl imaging with cardiac CZT camera
    Rouzet, F.
    Chequer, R.
    Milliner, M.
    Hyafil, F.
    Burg, S.
    Askienazy, S.
    Le Guludec, D.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S171 - S171
  • [2] I-123-MIBG myocardial scintigraphy in diabetic patients: Relationship to autonomic neuropathy
    Nagamachi, S
    Jinnouchi, S
    Nakahara, H
    Flores, LG
    Ohnishi, T
    Hoshi, H
    Futami, S
    Watanabe, K
    Nakatsuru, K
    Toshimori, T
    Matsukura, S
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (07) : 621 - 632
  • [3] CARDIAC 123I-MIBG SCINTIGRAPHY
    Wyborn, R.
    [J]. INTERNAL MEDICINE JOURNAL, 2011, 41 : 1 - 1
  • [4] Evaluation of 123I-MIBG uptake into the adrenal medulla in 123I-MIBG scintigraphy
    Abe, S.
    Kato, K.
    Odagawa, T.
    Fujita, N.
    Fujita, Y.
    Niwa, A.
    Naganawa, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S380 - S381
  • [5] Energy window optimization in dual isotope 201Tl/123I-MIBG SPECT with a CZT cardiac camera
    Avet, John
    Pina-Jomir, Geraldine
    Tylski, Perrine
    Scheiber, Christian
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [6] Myocardial 123I-MIBG Uptake and Cardiovascular Autonomic Function in Parkinson's Disease
    Katagiri, Akira
    Asahina, Masato
    Araki, Nobuyuki
    Poudel, Anupama
    Fujinuma, Yoshikatsu
    Yamanaka, Yoshitaka
    Kuwabara, Satoshi
    [J]. PARKINSONS DISEASE, 2015, 2015
  • [7] 123I-MIBG myocardial scintigraphy in patients with "takotsubo" cardiomyopathy
    Akashi, YJ
    Nakazawa, K
    Sakakibara, M
    Miyake, F
    Musha, H
    Sasaka, K
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (07) : 1121 - 1127
  • [8] Reduction of cardiac 123I-MIBG uptake in pure autonomic failure
    Kashihara, K.
    Ohno, M.
    Kawada, S.
    Imamura, T.
    Okumura, Y.
    [J]. MOVEMENT DISORDERS, 2006, 21 : S623 - S623
  • [9] Cardiac 123I-MIBG scintigraphy in patients with essential tremor
    Lee, Phil Hyu
    Kim, Ji Won
    Bang, Oh Young
    Joo, In Soo
    Yoon, Seok-Nam
    Huh, Kyoon
    [J]. MOVEMENT DISORDERS, 2006, 21 (08) : 1235 - 1238
  • [10] Efficacy of cardiac resynchronization therapy to cardiac sympathetic function evaluated by 123I-MIBG myocardial scintigraphy
    Imamura, K.
    Okajima, K.
    Shimane, A.
    Kanda, G.
    Taniguchi, Y.
    Hayashi, T.
    Yamada, S.
    Mizutani, K.
    Iwata, S.
    Kajiya, T.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 1013 - 1013