Evaluation of head posture using an inertial measurement unit

被引:0
|
作者
Mustafa Al-Yassary
Kelly Billiaert
Gregory S. Antonarakis
Stavros Kiliaridis
机构
[1] University Clinics of Dental Medicine,Division of Orthodontics
[2] University of Geneva,Dept of Orthodontics and Dentofacial Orthopaedics, School of Dental Medicine
[3] University of Bern,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
An inertial measurement unit (IMU) is an electronic device that measures and track the orientation of a body. We conducted this study in accordance with the STARD guidelines to evaluate the accuracy of IMU (index test) for measuring head posture compared to the current gold standard using a cervical range of motion (CROM) device. The reproducibility of the hunter and mirror-guided head posture was also evaluated. In vitro and in vivo tests were carried out to assess the validity of the IMU. To assess reproducibility, thirty healthy young adults were asked to look at four different locations in two different sessions while the head posture was recorded. Excellent correlation (r = 0.99; p < 0.001) was found between the IMU and CROM device with an absolute mean difference of 0.45° ± 0.58° (p = 0.85) for the in vitro test and 0.88° ± 1.20° (p = 0.99) for the in vivo test. For the reproducibility test, moderate to good correlation coefficients were found (r = 0.55 to 0.89; all p < 0.05) between the two sessions. The intraclass correlation coefficient ranged from moderate to excellent reliability (ICC from 0.74 to 0.96). These results suggest that the IMU sensors, when calibrated correctly, can be adequate to analyze head posture.
引用
收藏
相关论文
共 50 条
  • [1] Evaluation of head posture using an inertial measurement unit
    Al-Yassary, Mustafa
    Billiaert, Kelly
    Antonarakis, Gregory S.
    Kiliaridis, Stavros
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Postoperative Head Tracking: Repeatability of Measurements Using an Inertial Measurement Unit
    Prahs, Philipp M.
    Cvetkova, Nadezhda
    Helbi, Horst
    Maerker, David
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [3] Balance Evaluation by Inertial Measurement Unit
    Codina, Marc
    Navarrete, Manuel
    Castells-Rufas, David
    Carrabina, Jordi
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON UBIQUITOUS COMPUTING & AMBIENT INTELLIGENCE (UCAMI 2022), 2023, 594 : 71 - 76
  • [4] Evaluation and Calibration of an Inertial Measurement Unit
    Pervez, Md. Riaz
    Ahamed, Hafiz
    Islam, Md. Manirul
    Hille, Christof
    Roth, Hubert
    [J]. 8TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING, 2019, 2121
  • [5] Real-Time Forward Head Posture Detection and Correction System Utilizing an Inertial Measurement Unit Sensor
    Park, Gyumin
    Jung, Im Y.
    [J]. Applied Sciences (Switzerland), 2024, 14 (19):
  • [6] Inertial Measurement Unit: Evaluation for Indoor Positioning
    Ksentini, Dalila
    Elhadi, A. Rahim
    Lasla, Noureddine
    [J]. 2014 International Conference on Advanced Networking Distributed Systems and Applications (INDS 2014), 2014, : 25 - 30
  • [7] Evaluation of spinal posture during gait with inertial measurement units
    Digo, Elisa
    Pierro, Giuseppina
    Pastorelli, Stefano
    Gastaldi, Laura
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (10) : 1094 - 1105
  • [8] PERFORMANCE EVALUATION OF A REDUNDANT INERTIAL MEASUREMENT UNIT
    BLETSOS, NA
    BLAIR, WP
    [J]. ISA TRANSACTIONS, 1984, 23 (04) : 9 - 16
  • [9] Ship Motion Measurement Using an Inertial Measurement Unit
    Abankwa, Nana O.
    Johnston, Steven J.
    Scott, Mark
    Cox, Simon J.
    [J]. 2015 IEEE 2ND WORLD FORUM ON INTERNET OF THINGS (WF-IOT), 2015, : 375 - 380
  • [10] Robust Classification of Hand Posture to Arm Posture Change Using Inertial Measurement Units
    Choi, Hwiyong
    Hwang, Daehyun
    Lee, Sangyoon
    [J]. 2014 IEEE 4TH ANNUAL INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2014, : 231 - 235