Capillary pumps with constant flow rate

被引:0
|
作者
Wouter van der Wijngaart
机构
[1] KTH Royal Institute of Technology,Micro and Nanosystems Department
来源
关键词
Constant Flow Rate; Capillary Suction; Liquid Front; Develop Laminar Flow; Lateral Flow Device;
D O I
暂无
中图分类号
学科分类号
摘要
This paper unambiguously derives, ab initio starting from the Navier–Stokes and Laplace equations, the geometric parameters defining capillary pumps (CPs) with rectangular cross section with constant volumetric flow rate and steady velocity profile. The parametric formulation of the channel shape is derived using Taylor series approximations of the capillary pressure and the hydrodynamic flow resistance with negligible error. First, the design parameters are derived for a CP consisting of a single channel and illustrated with an example. Thereafter, the design parameters for multichannel and for micropillar array CPs are derived. Finally, the design of CPs for multistep constant flow rates derived and those for arbitrarily varying flow rates are discussed.
引用
收藏
页码:829 / 837
页数:8
相关论文
共 50 条
  • [1] Capillary pumps with constant flow rate
    van der Wijngaart, Wouter
    MICROFLUIDICS AND NANOFLUIDICS, 2014, 16 (05) : 829 - 837
  • [2] Erratum to: Capillary pumps with constant flow rate
    Wouter van der Wijngaart
    Microfluidics and Nanofluidics, 2014, 16 (5) : 839 - 839
  • [3] Programming piston displacements for constant flow rate piston pumps with trigonometric transition functions
    Tian, Zhongxu
    Lin, Xingxing
    MECHANICAL SCIENCES, 2021, 12 (01) : 559 - 571
  • [4] Autonomous capillary microfluidic devices with constant flow rate and temperature-controlled valving
    Li, Lanhui
    Westerbeek, Eiko Y.
    Vollenbroek, Jeroen C.
    de Beer, Sissi
    Shui, Lingling
    Odijk, Mathieu
    Eijkel, Jan C. T.
    SOFT MATTER, 2021, 17 (33) : 7781 - 7791
  • [5] CAPILLARY PUMPING WITH A CONSTANT FLOW RATE INDEPENDENT OF THE LIQUID SAMPLE VISCOSITY AND SURFACE ENERGY
    Guo, Weijin
    Hansson, Jonas
    van der Wijngaart, Wouter
    30TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2017), 2017, : 339 - 341
  • [6] High flow rate microfluidic pumps
    Goulpeau, J
    Trouchet, D
    Tabeling, P
    MICRO TOTAL ANALYSIS SYSTEMS 2004, VOL 1, 2005, (296): : 261 - 263
  • [7] Theoretical flow rate in crescent pumps
    Rundo, Massimo
    SIMULATION MODELLING PRACTICE AND THEORY, 2017, 71 : 1 - 14
  • [8] Operating principles and clinical implications of constant flow pumps
    Cameron, T
    Wigness, BD
    Bedder, MD
    NEUROMODULATION, 2002, 5 (03): : 160 - 166
  • [9] AIR VOLUME MEASUREMENT ERROR IN PUMPS WITH ROTAMETERS AND HIGH RANGE CONSTANT FLOW PUMPS
    WEISS, SA
    BEAULIEU, HJ
    BUCHAN, RM
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1982, 43 (10): : 754 - 758
  • [10] Flow rate limitation in open capillary flow
    Rosendahl, U
    Dreyer, ME
    Rath, HJ
    2ND EUROPEAN SYMPOSIUM ON UTILISATION OF THE INTERNATIONAL SPACE STATION, 1999, 433 : 255 - 260