Geometry-driven-diffusion filtering of magnetic resonance images using model-based conductance

被引:0
|
作者
Ivan Bajla
Igor Holländer
机构
[1] Austrian Research Centers Seibersdorf,
[2] Department of High-Performance Image Processing,undefined
[3] 2444 Seibersdorf,undefined
[4] Austria; Tel: (+)43 50550 2903; Fax: (+)43 2254 72133; e-mail: ivan.bajla@arcs.ac.at ,undefined
[5] University of Manchester,undefined
[6] Manchester,undefined
[7] UK ,undefined
来源
关键词
Key words: Nonlinear image filtering – Geometry-driven diffusion – Image segmentation – Model-based image processing – Magnetic resonance imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The paper deals with the problems of staircase artifacts and low-contrast boundary smoothing in filtering (magnetic resonance MR) brain tomograms that is based on geometry-driven diffusion (GDD). A novel method of the model-based GDD filtering of MR brain tomograms is proposed to tackle these problems. It is based on a local adaptation of the conductance that is defined for each diffusion iteration within the variable limits. The local adaptation uses a neighborhood inhomogeneity measure, pixel dissimilarity, while gradient histograms of MR brain template regions are used as the variable limits for the conductance. A methodology is developed for implementing the template image selected from an MR brain atlas to the model-based GDD filtering. The proposed method is tested on an MR brain phantom. The methodology developed is exemplified on the real MR brain tomogram with the corresponding template selected from the Brainweb. The performance of the developed algorithms is evaluated quantitatively and visually.
引用
收藏
页码:223 / 237
页数:14
相关论文
共 50 条
  • [1] Geometry-driven-diffusion filtering of magnetic resonance images using model-based conductance
    Bajla, I
    Holländer, I
    MACHINE VISION AND APPLICATIONS, 2001, 12 (05) : 223 - 237
  • [2] Locally adaptive conductance in geometry-driven-diffusion filtering of magnetic resonance tomograms
    Bajla, I
    Holländer, I
    IEE PROCEEDINGS-VISION IMAGE AND SIGNAL PROCESSING, 2000, 147 (03): : 271 - 282
  • [3] Nonlinear filtering of magnetic resonance tomograms by geometry-driven diffusion
    Ivan Bajla
    Igor Holländer
    Machine Vision and Applications, 1998, 10 : 243 - 255
  • [4] Nonlinear filtering of magnetic resonance tomograms by geometry-driven diffusion
    Bajla, I
    Hollander, I
    MACHINE VISION AND APPLICATIONS, 1998, 10 (5-6) : 243 - 255
  • [5] Bilateral filtering of diffusion tensor magnetic resonance images
    Hamarnesh, Ghassan
    Hradsky, Judith
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2007, 16 (10) : 2463 - 2475
  • [6] Geometry-driven diffusion smoothing of the MR-brain images using a novel variable conductance
    Bajla, I
    Hollander, I
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 743 - 745
  • [7] Skull-stripping magnetic resonance brain images using a model-based level set
    Zhuang, Audrey H.
    Valentino, Daniel J.
    Toga, Arthur W.
    NEUROIMAGE, 2006, 32 (01) : 79 - 92
  • [8] A stochastic geometry model for functional magnetic resonance images
    Hartvig, NV
    SCANDINAVIAN JOURNAL OF STATISTICS, 2002, 29 (03) : 333 - 353
  • [9] Model-based separation filtering of magnetic data
    Pilkington, M
    Cowan, DR
    GEOPHYSICS, 2006, 71 (02) : L17 - L23
  • [10] Confidence based anisotropic filtering of magnetic resonance images
    Bayram, E
    Ge, YR
    Wyatt, CL
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2526 - 2529