Voltammetric determination of copper at chemically modified electrodes based on crown ethers

被引:0
|
作者
V. S. Ijeri
A. K. Srivastava
机构
[1] Department of Chemistry,
[2] University of Mumbai,undefined
[3] Vidyanagari,undefined
[4] Santacruz(E),undefined
[5] Mumbai – 400 098,undefined
[6] Maharashtra,undefined
[7] India,undefined
关键词
Copper; Ether; Graphite; Detection Limit; Crown Ether;
D O I
暂无
中图分类号
学科分类号
摘要
The feasibility of fabricating copper-sensitive chemically modified electrodes (CMEs) for trace analysis in aqueous and in 40% (v/v) ethanol-water media was investigated. Carbon paste electrodes modified with crown ethers were constructed by mixing the crown ethers into a graphite powder-paraffin oil matrix. The electrodes so formed were able to bind Cu(II) ions chemically and gave better voltammetric responses than the unmodified ones. The crown ethers studied and compared were 15-crown-5, benzo-15-crown-5 and dibenzo-18-crown-6. With a 3% benzo-15-crown-5 CME, Cu(II) could be quantified at sub-ppm levels by differential pulse voltammetry with a detection limit of 0.05 ppm. By differential pulse anodic stripping voltammetry Cu(II) could be quantified over the range 1 to 100 ppb. Interference from metal ions like Ni(II), Co(II), Mn(II), Fe(II), etc. have also been studied. The method was successfully applied to artificial as well as commercial samples of alcoholic beverages.
引用
收藏
页码:373 / 377
页数:4
相关论文
共 50 条
  • [1] Voltammetric determination of copper at chemically modified electrodes based on crown ethers
    Ijeri, VS
    Srivastava, AK
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (04): : 373 - 377
  • [2] Voltammetric Determination of Lead at Chemically Modified Electrodes Based on Crown Ethers
    Vijaykumar S. Ijeri
    Ashwini K. Srivastava
    [J]. Analytical Sciences, 2001, 17 : 605 - 608
  • [3] Voltammetric determination of lead at chemically modified electrodes based on crown ethers
    Ijeri, VS
    Srivastava, AK
    [J]. ANALYTICAL SCIENCES, 2001, 17 (05) : 605 - 608
  • [4] VOLTAMMETRIC SENSORS BASED ON PRECONCENTRATING CHEMICALLY MODIFIED ELECTRODES
    WANG, J
    ZADEII, J
    MARTINEZ, T
    DARNALL, D
    GARDEATORRESDEY, J
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 121 - ANYL
  • [5] Voltammetric techniques at chemically modified electrodes
    Chillawar, Rakesh R.
    Tadi, Kiran Kumar
    Motghare, Ramani V.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (04) : 399 - 418
  • [6] Voltammetric techniques at chemically modified electrodes
    Rakesh R. Chillawar
    Kiran Kumar Tadi
    Ramani V. Motghare
    [J]. Journal of Analytical Chemistry, 2015, 70 : 399 - 418
  • [7] ANODIC STRIPPING VOLTAMMETRIC DETERMINATION OF LEAD USING A CHEMICALLY MODIFIED ELECTRODE BASED ON AZA CROWN ETHER
    Segura, Rodrigo
    Diaz, Karina
    Pizarro, Jaime
    Placencio, Alan
    Tapia, Diego
    Fajardo, Angelo
    [J]. JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2017, 62 (04): : 3726 - 3730
  • [8] Development in voltammetric analysis with chemically modified electrodes and biosensors
    Labuda, J
    Vanícková, M
    Bucková, M
    Korgová, E
    [J]. CHEMICAL PAPERS, 2000, 54 (02): : 95 - 103
  • [9] CHEMICALLY MODIFIED CARBON PASTE ELECTRODES IN VOLTAMMETRIC ANALYSIS
    KALCHER, K
    [J]. ELECTROANALYSIS, 1990, 2 (06) : 419 - 433
  • [10] APPLICATION OF CHEMICALLY MODIFIED ELECTRODES TO ORGANIC VOLTAMMETRIC ANALYSIS
    BALDWIN, RP
    PRICE, JF
    SIRIA, J
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 18 - 18