Multi-bed-position acquisition technique for deep inspiration breath-hold PET/CT: a preliminary result for pulmonary lesions

被引:0
|
作者
Hiromitsu Daisaki
Hiroyuki Shinohara
Takashi Terauchi
Takeshi Murano
Naoki Shimada
Noriyuki Moriyama
Ukihide Tateishi
机构
[1] National Cancer Center,Screening Technology and Development Division, Research Center for Cancer Prevention and Screening
[2] Tokyo Metropolitan University,Division of Radiological Science, Graduate School of Medicine
[3] Yokohama City University,Department of Diagnostic Radiology, Graduate School of Medicine
来源
Annals of Nuclear Medicine | 2010年 / 24卷
关键词
FDG; PET/CT; Breath-hold; Pulmonary; Cancer;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:179 / 188
页数:9
相关论文
共 50 条
  • [1] Multi-bed-position acquisition technique for deep inspiration breath-hold PET/CT: a preliminary result for pulmonary lesions
    Daisaki, Hiromitsu
    Shinohara, Hiroyuki
    Terauchi, Takashi
    Murano, Takeshi
    Shimada, Naoki
    Moriyama, Noriyuki
    Tateishi, Ukihide
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (03) : 179 - 188
  • [2] Optimum emission time in deep-inspiration breath-hold PET–CT: a preliminary result
    Koichi Miyashita
    Ukihide Tateishi
    Yuji Nishiyama
    Ryogo Minamimoto
    Kazuya Shizukuishi
    Tomio Inoue
    Annals of Nuclear Medicine, 2010, 24 : 559 - 563
  • [3] Optimum emission time in deep-inspiration breath-hold PET-CT: a preliminary result
    Miyashita, Koichi
    Tateishi, Ukihide
    Nishiyama, Yuji
    Minamimoto, Ryogo
    Shizukuishi, Kazuya
    Inoue, Tomio
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (07) : 559 - 563
  • [4] Deep-inspiration breath-hold PET/CT of the thorax
    Nehmeh, Sadek A.
    Erdi, Yusuf E.
    Meirelles, Gustavo S. P.
    Squire, Olivia
    Larson, Steven M.
    Humm, John L.
    Schoder, Heiko
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (01) : 22 - 26
  • [5] Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
    Shozo Yamashita
    Kunihiko Yokoyama
    Masahisa Onoguchi
    Haruki Yamamoto
    Shigeaki Hiko
    Akihiro Horita
    Kenichi Nakajima
    Annals of Nuclear Medicine, 2014, 28 : 1 - 10
  • [6] Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
    Yamashita, Shozo
    Yokoyama, Kunihiko
    Onoguchi, Masahisa
    Yamamoto, Haruki
    Hiko, Shigeaki
    Horita, Akihiro
    Nakajima, Kenichi
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (01) : 1 - 10
  • [7] Respiratory-gated and deep inspiration breath-hold FDG PET/CT protocols for evaluation of pulmonary and abdominal lesions
    Aga, Fumitoshi
    Yamamoto, Yuka
    Maeda, Yukito
    Takahashi, Yousuke
    Nishiyama, Yoshihiro
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [8] Deep-inspiration breath-hold PET/CT:: Clinical findings with a new technique for detection and characterization of thoracic lesions
    Meirelles, Gustavo S. P.
    Erdi, Yusuf Emre
    Nehmeh, Sadek A.
    Squire, Olivia D.
    Larson, Steven M.
    Humm, John L.
    Schoder, Heiko
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) : 712 - 719
  • [9] Combined CT and SPECT deep inspiration breath-hold acquisition in myocardial imaging
    Clerc, Olivier
    Buechel, Ronny
    Fuchs, Tobias
    Possner, Mathias
    Svetlana, Dougoud
    Stehli, Julia
    Kaufmann, Philipp
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [10] Deep inspiration breath-hold technique using an Arduino
    Gallego, P.
    Perez-Alija, J.
    Olivares, S.
    Loscos, S.
    Ambroa, E.
    Pedro, A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S811 - S811