Inter-scorer reliability of sleep assessment using EEG and EOG recording system in comparison to polysomnography

被引:0
|
作者
Shigeru Nonoue
Midori Mashita
Shingo Haraki
Akira Mikami
Hiroyoshi Adachi
Hirofumi Yatani
Atsushi Yoshida
Masako Taniike
Takafumi Kato
机构
[1] Osaka University Graduate School of Medicine,Department of Psychiatry
[2] Osaka University Hospital,Sleep Medicine Center
[3] Osaka University Graduate School of Dentistry,Department of Fixed Prosthodontics
[4] Osaka University Graduate School of Dentistry,Department of Oral Anatomy and Neurobiology
[5] Osaka University,Support Center for Campus Life
[6] Osaka University Health Care Center,United Graduate School of Child Development
[7] Osaka University,undefined
来源
关键词
Sleep; Forehead EEG; EOG; Portable system; PSG; Reliability;
D O I
暂无
中图分类号
学科分类号
摘要
There are increasing needs for self-applicable methods assessing sleep in clinical and non-clinical settings. This study aimed to investigate the inter-scorer reliability for the sleep stage scoring and for the sleep variable assessments in the portable electroencephalography (EEG) and electro-oculography (EOG) recording system. Sleep recordings were performed simultaneously with polysomnography (PSG) and portable EEG/EOG recordings in 14 healthy adults. The inter-scorer concordance of the sleep stage scoring was assessed in the two recording methods. Sleep variables were compared between the two methods using the Bland–Altman plots in each scorer. The overall inter-scorer concordance rate of sleep stage scoring for the EEG/EOG data was 85.5 %, and the Cohen’s κ was 0.80 (p < 0.001), being equivalent to those for the PSG data (89.2 %, 0.85, p < 0.001) while that for StageN1 was relatively low (EEG/EOG 60.1 %, PSG 71.7 %). In both scorers, Bland–Altman plots showed that the mean difference between sleep variables obtained from the two systems was within the acceptable range although the inter-class correlations between the two systems were lower for StageN2 or StageR in either scorer. Although the results suggest that the sufficient inter-scorer reliability can be obtained with the EEG/EOG recording system based on manual sleep stage scoring in healthy young adults, the nature of the EEG/EOG recording system can influence the precisions in manually assessing sleep architectures in comparison to PSG.
引用
收藏
页码:39 / 48
页数:9
相关论文
共 25 条
  • [1] Inter-scorer reliability of sleep assessment using EEG and EOG recording system in comparison to polysomnography
    Nonoue, Shigeru
    Mashita, Midori
    Haraki, Shingo
    Mikami, Akira
    Adachi, Hiroyoshi
    Yatani, Hirofumi
    Yoshida, Atsushi
    Taniike, Masako
    Kato, Takafumi
    SLEEP AND BIOLOGICAL RHYTHMS, 2017, 15 (01) : 39 - 48
  • [2] External proficiency testing improves inter-scorer reliability of polysomnography scoring
    Warren R. Ruehland
    Peter D. Rochford
    Robert J. Pierce
    Parmjit Singh
    Andrew T. Thornton
    Sleep and Breathing, 2023, 27 : 923 - 932
  • [3] External proficiency testing improves inter-scorer reliability of polysomnography scoring
    Ruehland, Warren R.
    Rochford, Peter D.
    Pierce, Robert J.
    Singh, Parmjit
    Thornton, Andrew T.
    SLEEP AND BREATHING, 2023, 27 (03) : 923 - 932
  • [4] A CROSS-VALIDATION APPROACH TO INTER-SCORER RELIABILITY ASSESSMENT
    Fernandez, C.
    Rusk, S.
    Glattard, N.
    Hensen, B.
    Shokoueinejad, M.
    Creado, S.
    Hungerford, J.
    SLEEP, 2018, 41 : A122 - A123
  • [5] The American Academy of Sleep Medicine Inter-scorer Reliability Program: Sleep Stage Scoring
    Rosenberg, Richard S.
    Van Hout, Steven
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2013, 9 (01): : 81 - 87
  • [6] The American Academy of Sleep Medicine Inter-scorer Reliability Program: Respiratory Events
    Rosenberg, Richard S.
    Van Hout, Steven
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2014, 10 (04): : 447 - 454
  • [7] Inter-scorer reliability between Somno-Art Software and 5 sleep centers
    Viola, A.
    Thiesse, L.
    Staner, L.
    Fuchs, G.
    Kirscher, D.
    Dehouck, V.
    Schaffhauser, J. Y.
    Roth, T.
    Saoud, J.
    Luthringer, R.
    JOURNAL OF SLEEP RESEARCH, 2022, 31
  • [8] High inter-scorer reliability for sleep stage does not always indicate absence of rater effects
    Norman, RG
    Scott, MA
    Walsleben, JA
    SLEEP, 2003, 26 : A387 - A387
  • [9] Inter-scorer Reliability between Sleep Centers Can Teach Us What to Improve in the Scoring Rules
    Penzel, Thomas
    Zhang, Xiaozhe
    Fietze, Ingo
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2013, 9 (01): : 89 - 91
  • [10] Comparison of Night-to-Night and Inter-scorer Variability of Different Indices of Obstructive Sleep Apnea Severity in the MARIPOSA Trial
    Pho, H.
    Sands, S. A.
    Azarbarzin, A.
    Wellman, A.
    Messineo, L.
    Strassberger, C.
    Farkas, R.
    White, D. P.
    Taranto-Montemurro, L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207