Enzyme-catalyzed reaction of voltammetric enzyme-linked immunoassay system based on OAP as substrate

被引:0
|
作者
Shusheng Zhang
Hongyuan Chen
Kui Jiao
机构
[1] Nanjing University,Department of Chemistry
[2] Qingdao Institute of Chemical Technology,Department of Applied Chemistry
来源
Science in China Series B: Chemistry | 1999年 / 42卷
关键词
-aminophenol; horseradish peroxidase; voltammetry; enzyme-catalysis; electrochemical immunoassay;
D O I
暂无
中图分类号
学科分类号
摘要
Theo-aminophenol (OAP)-H2O2-horseradish peroxidase (HRP) voltammetric enzyme-linked immunoassay new system has extremely high sensitivity. HRP can be measured with a detection limit of 6.0×1010 g/L and a linear range of 1.0×10-9-4.0×10-6 g/L. The pure product of H2O2 oxidizing OAP catalyzed by HRP was prepared with chemical method. The enzyme-catalyzed reaction has been investigated with electroanalytical chemistry, UV/Vis spectrum, IR spectrum,13C NMR,1H NMR, mass spectrum, elemental analysis, etc. Under the selected enzyme-catalyzed reaction conditions, the oxidation product of OAP with H2O2 catalyzed by HRP is 2-aminophenoxazine-3-one. The processes of the enzyme-catalyzed reaction and the electroreduction of the product of the enzymecatalyzed reaction have been described.
引用
收藏
页码:195 / 203
页数:8
相关论文
共 50 条
  • [1] Enzyme-catalyzed reaction of voltammetric enzyme-linked immunoassay system based on OAP as substrate
    张书圣
    陈洪渊
    焦奎
    Science in China(Series B), 1999, (02) : 195 - 203
  • [2] Enzyme-catalyzed reaction of voltammetric enzyme-linked immunoassay system based on OAP as substrate
    Zhang, SS
    Chen, HY
    Jiao, K
    SCIENCE IN CHINA SERIES B-CHEMISTRY, 1999, 42 (02): : 195 - 203
  • [3] Enzyme-catalyzed reaction of OPD-H202-HRP voltammetric enzyme-linked immunoassay system
    Kui Jiao
    Gang Sun
    Shusheng Zhang
    Science in China Series B: Chemistry, 1998, 41 : 345 - 352
  • [4] Enzyme-catalyzed reaction of OPD-H2O2-HRP voltammetric enzyme-linked immunoassay system
    焦奎
    孙刚
    张书圣
    Science in China(Series B), 1998, (04) : 345 - 352
  • [5] Enzyme-catalyzed reaction of OPD-H2O2-HRP voltammetric enzyme-linked immunoassay system
    Jiao, K
    Sun, G
    Zhang, SS
    SCIENCE IN CHINA SERIES B-CHEMISTRY, 1998, 41 (04): : 345 - 352
  • [6] Investigation of voltammetric enzyme-linked immunoassay based on a new system of OAP-H2O2-HRP
    Zhang, SS
    Jiao, K
    Chen, HY
    ELECTROANALYSIS, 1999, 11 (07) : 511 - 516
  • [7] Investigation of voltammetric enzyme-linked immunoassay system based on N-heterocyclic substrate of 2,3-diaminopyridine
    Yu, Fengli
    Du, Ping
    Lei, Xi
    Zhang, Shusheng
    TALANTA, 2009, 78 (4-5) : 1395 - 1400
  • [8] OAP-H2O2-HRP voltammetric enzyme-linked immunoassay for trace ferritin in human serum
    Zhang, SS
    Jiao, K
    Chen, HY
    ACTA CHIMICA SINICA, 1999, 57 (08) : 914 - 921
  • [9] A system of p-nitrophenylphosphate-alkaline phosphatase for voltammetric enzyme-linked immunoassay
    Jiao, K
    Sun, W
    Wang, HY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (10) : 1174 - 1177
  • [10] Enzyme Immunoassay and Enzyme-Linked Immunosorbent Assay
    Gan, Stephanie D.
    Patel, Kruti R.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2013, 133 (09) : E10 - E12