Biomechanical and histomorphometric evaluation of skin integration on titanium and PEEK implants with different surface treatments

被引:0
|
作者
Per Kjellin
Karin Danielsson
Joakim Håkansson
Karin Agrenius
Therese Andersson
Patrik Stenlund
机构
[1] Promimic AB,Department of Methodology, Textile and Medical Technology
[2] AstraZeneca BioventureHub,Department of Laboratory Medicine, Institute of Biomedicine
[3] RISE Research Institutes of Sweden,undefined
[4] Gothenburg University,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Percutaneous implants are frequently affected by bacterial growth at the skin-implant interface. Integration between implant and surrounding skin is important to prevent bacteria from spreading to the underlying tissue. The standard method to evaluate skin-implant integration is by histomorphometry on samples which have been placed in tissue grown in vivo or ex vivo. In this study, a biomechanical method was developed and evaluated. The integration of implants into porcine skin was studied in an ex vivo model, where pig skin samples were cultivated in a nutrient solution. Cylindrical shaped implants, consisting of polyether ether ketone (PEEK) and titanium (Ti) with different surface treatments, were implanted in the skin tissue and the skin was grown in nutrient solution for 2 weeks. The implants were then extracted from the implantation site and the mechanical force during extraction was measured as a quantitative assessment of skin-implant integration. Implants from each group were also processed for histomorphometry and the degree of epidermal downgrowth (ED) and tissue to implant contact (TIC) was measured. A higher mean pullout force was observed for the PEEK implants compared to the Ti implants. Applying nanosized hydroxyapatite (HA) on Ti and PEEK increased the pullout force compared to uncoated controls, 24% for machined and 70% for blasted Ti, and 51% for machined PEEK. Treatment of Ti and PEEK with nanosized zirconium phosphate (ZrP) did not increase the pullout force. The histomorphometry analysis showed correlation between ED and pullout force, where the pullout force was inversely proportional to ED. For TIC, no significant differences were observed between the groups of same material (i.e. Ti, Ti+HA, Ti+ZrP, and PEEK, PEEK + HA, PEEK + ZrP), but it was significantly higher for PEEK compared to Ti. Scanning electron microscopy analysis was done on samples before and after the pullout tests, showing that the ZrP coating was unaffected by the 2 week ex vivo implantation and pullout procedure, no dissolution or detachment of the coating was observed. For the HA coating, a loss of coating was seen on approximately 5% of the total surface area of the implant.
引用
收藏
相关论文
共 50 条
  • [1] Biomechanical and histomorphometric evaluation of skin integration on titanium and PEEK implants with different surface treatments
    Kjellin, Per
    Danielsson, Karin
    Hakansson, Joakim
    Agrenius, Karin
    Andersson, Therese
    Stenlund, Patrik
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2022, 33 (10)
  • [2] Biomechanical and Histomorphometric Study of Dental Implants With Different Surface Characteristics
    Yeo, In-Sung
    Han, Jung-Suk
    Yang, Jae-Ho
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 87B (02) : 303 - 311
  • [3] Mechanical and histomorphometric evaluations of titanium implants with different surface treatments inserted in sheep cortical bone
    Giavaresi, G
    Fini, M
    Cigada, A
    Chiesa, R
    Rondelli, G
    Rimondini, L
    Torricelli, P
    Aldini, NN
    Giardino, R
    [J]. BIOMATERIALS, 2003, 24 (09) : 1583 - 1594
  • [4] Histomorphometric and microhardness assessments of sheep cortical bone surrounding titanium implants with different surface treatments
    Giavaresi, G
    Fini, M
    Cigada, A
    Chiesa, R
    Rondelli, G
    Rimondini, L
    Aldini, NN
    Martini, L
    Giardino, R
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 67A (01): : 112 - 120
  • [5] Histomorphometric evaluation of immediately loaded SSII implants of different surface treatments in a dog model
    Jeon, Woo-Jin
    Kim, Su-Gwan
    Lim, Sung-Chul
    Ong, Joo L.
    Oh, Daniel Sunho
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 90A (02) : 396 - 400
  • [6] SEM-EDS and biomechanical evaluation of implants with different surface treatments: an initial study
    Tavares, Hewerson Santos
    Faeda, Rafael Silveira
    Guastaldi, Antonio Carlos
    Semeghini Guastaldi, Fernando Pozzi
    Oliveira, Nilson T. C.
    Marcantonio, Elcio, Jr.
    [J]. JOURNAL OF OSSEOINTEGRATION, 2009, 1 (01) : 15 - 21
  • [7] INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS
    BUSER, D
    SCHENK, RK
    STEINEMANN, S
    FIORELLINI, JP
    FOX, CH
    STICH, H
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07): : 889 - 902
  • [8] Effect of different surface treatments on bioactivity of porous titanium implants
    M.Todea
    A.Vulpoi
    C.Popa
    P.Berce
    S.Simon
    [J]. Journal of Materials Science & Technology, 2019, 35 (03) : 418 - 426
  • [9] Laser-Treated Titanium Implants: An In Vivo Histomorphometric and Biomechanical Analysis
    Trisi, Paolo
    Berardini, Marco
    Colagiovanni, Marco
    Berardi, Davide
    Perfetti, Giorgio
    [J]. IMPLANT DENTISTRY, 2016, 25 (05) : 575 - 580
  • [10] Effect of different surface treatments on bioactivity of porous titanium implants
    Todea, M.
    Vulpoi, A.
    Popa, C.
    Berce, P.
    Simon, S.
    [J]. JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2019, 35 (03) : 418 - 426