Calcium functional imaging with high-resolution CT in the inner ear

被引:0
|
作者
Hisaya Tanioka
Sayaka Tanioka
机构
[1] Tanioka Clinic,
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Although the otolith and otolith organs correlate with vertigo and instability, there is no method to investigate them without harmful procedures. We will create the technique for 3D microanatomical images of them, and investigate the in vivo internal state and metabolisms. The otolith and otolith organs images were reconstructed from a texture synthesis algorithm under the skull volume rendering algorithm using a cutting-plane method. The utricular macula was elongated pea-shaped. The saccular macula was almost bud-shaped. The changes in the amount of CaCO3 in the maculae and the endolymphatic sac showed various morphologies, reflecting the balance status of each subject. Both shapes and volumes were not always constant depending on time. In Meniere’s disease (MD), the saccular macula was larger and the utricular macula was smaller. In benign paroxysmal positional vertigo (BPPV), the otolith increased in the utricular macula but did not change much in the saccular macula. The saccule, utricle, and endolymphatic sac were not constantly shaped according to their conditions. These created 3D microanatomical images can allow detailed observations of changes in physiological and biological information. This imaging technique will contribute to our understanding of pathology and calcium metabolism in the in vivo vestibulum.
引用
收藏
相关论文
共 50 条
  • [1] Calcium functional imaging with high-resolution CT in the inner ear
    Tanioka, Hisaya
    Tanioka, Sayaka
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] HIGH-RESOLUTION CT FOR ABNORMALITIES OF THE INNER-EAR
    KOSTER, O
    SCHLOLAUT, KH
    STRAEHLERPOHL, HJ
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 152 (06): : 644 - 648
  • [3] High-resolution volumetric CT of inner and middle ear
    Gupta, R
    Basu, S
    Ross, WJ
    Edic, PM
    Turek, M
    Nearn-Mtui, LC
    [J]. RADIOLOGY, 2001, 221 : 570 - 570
  • [4] HIGH-RESOLUTION CT OF THE MIDDLE AND INNER-EAR
    KOSTER, O
    BOCKLER, R
    LACKNER, K
    KOCH, U
    [J]. LARYNGOLOGIE RHINOLOGIE OTOLOGIE VEREINIGT MIT MONATSSCHRIFT FUR OHRENHEILKUNDE, 1984, 63 (10): : 488 - 493
  • [5] Imaging the inner ear in fossil mammals: High-resolution CT scanning and 3-D virtual reconstructions
    Ni, Xijun
    Flynn, John J.
    Wyss, Andre R.
    [J]. PALAEONTOLOGIA ELECTRONICA, 2012, 15 (02)
  • [6] The inner ear anatomy of the coelacanth revealed by high-resolution X-ray CT
    Bernstein, P
    [J]. INTEGRATIVE AND COMPARATIVE BIOLOGY, 2004, 44 (06) : 676 - 676
  • [7] HIGH-RESOLUTION MR IMAGING OF THE INNER-EAR - FINDINGS IN MENIERES-DISEASE
    TANIOKA, H
    ZUSHO, H
    MACHIDA, T
    SASAKI, Y
    SHIRAKAWA, T
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1992, 15 (01) : 83 - 88
  • [8] FAST SPIN-ECHO HIGH-RESOLUTION MR IMAGING OF THE INNER-EAR
    TIEN, RD
    FELSBERG, GJ
    MACFALL, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (02) : 395 - 398
  • [9] Normal standards of the ear in high-resolution CT
    Ben Romdhane, H
    Menif, E
    Douira, W
    Ben Massoud, M
    Slim, R
    [J]. RADIOLOGY, 2001, 221 : 135 - 135
  • [10] High resolution imaging of the mouse inner ear by microtomography: A new tool in inner ear research
    Van Spaendonck, MP
    Cryns, K
    Van de Heyning, PH
    Scheuermann, DW
    Van Camp, G
    Timmermans, JP
    [J]. ANATOMICAL RECORD, 2000, 259 (02): : 229 - 236