Optimization of a FACS based-immunoassay using E. coli autodisplaying Z-domains

被引:0
|
作者
Min Park
Ji-Hong Bong
Gu Yoo
Joachim Jose
Min-Jung Kang
Jae-Chul Pyun
机构
[1] Yonsei University,Department of Materials Science and Engineering
[2] University of Muenster,Institute of Pharmaceutical and Medical Chemistry
[3] Korea Institute of Science and Technology (KIST),undefined
来源
BioChip Journal | 2013年 / 7卷
关键词
Immunoassay; FACS; Z-domain; Medical diagnosis; Hepatitis B virus surface antigen;
D O I
暂无
中图分类号
学科分类号
摘要
We developed a fluorescence-activated cell sorter (FACS)-based immunoassay using Escherichia coli with autodisplayed Z-domains as a solid support for detection antibodies as well as a method to optimize the signal-to-noise ratio of fluorescence signals from E. coli. To improve the sensitivity of FACS measurements by eliminating artifactual signals from unrelated small particles in the sample mixture, E. coli with autodisplayed Z-domains was modified to express enhanced green fluorescence protein (eGFP) in the cytosol. By selectively gating the measurement channel for eGFP in the cytosol, we were able to discriminate between green fluorescent E. coli and artifact particles. We confirmed the efficacy of this optimization method for FACS-based immunoassay using several model reactions. Finally, as proof of concept, we used the FACS-based immunoassay and our optimization method for the medical diagnosis of human hepatitis B virus surface antigen.
引用
收藏
页码:173 / 179
页数:6
相关论文
共 50 条
  • [1] Optimization of a FACS based-immunoassay using E. coli autodisplaying Z-domains
    Park, Min
    Bong, Ji-Hong
    Yoo, Gu
    Jose, Joachim
    Kang, Min-Jung
    Pyun, Jae-Chul
    BIOCHIP JOURNAL, 2013, 7 (02) : 173 - 179
  • [2] Flow cytometric immunoassay using E. coli with autodisplayed Z-domains
    Park, Min
    Bong, Ji-Hong
    Yoo, Gu
    Jose, Joachim
    Kang, Min-Jung
    Pyun, Jae-Chul
    ENZYME AND MICROBIAL TECHNOLOGY, 2013, 53 (03) : 181 - 188
  • [3] Magnetic-bead-based immunoassay using E. coli cells with autodisplayed Z-domains
    Yoo, Gu
    Bong, Ji-Hong
    Park, Min
    Kang, Min-Jung
    Jose, Joachim
    Pyun, Jae-Chul
    ENZYME AND MICROBIAL TECHNOLOGY, 2013, 53 (02) : 118 - 122
  • [4] FACS-based immunoassay of troponin-I using E-coli cells with autodisplayed Z-domains
    Park, Min
    Bong, Ji-Hong
    Chang, Young Wook
    Yoo, Gu
    Jose, Joachim
    Kang, Min-Jung
    Pyun, Jae-Chul
    ANALYTICAL METHODS, 2014, 6 (06) : 1700 - 1708
  • [5] A Regenerative Immunoaffinity Layer Based on the Outer Membrane of Z-Domains Autodisplaying E-coli for Immunoassays and Immunosensors
    Jeon, Daseul
    Pyun, Jae-Chul
    Jose, Joachim
    Park, Min
    SENSORS, 2018, 18 (11)
  • [6] SPR biosensor by using E. coli outer membrane layer with autodisplayed Z-domains
    Park, Min
    Jose, Joachim
    Pyun, Jae-Chul
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 154 (02) : 82 - 88
  • [7] Hypersensitive immunoassay by using Escherichia coli outer membrane with autodisplayed Z-domains
    Park, Min
    Jose, Joachim
    Pyun, Jae-Chul
    ENZYME AND MICROBIAL TECHNOLOGY, 2010, 46 (3-4) : 309 - 314
  • [8] Electrochemical ELISA based on E.coli with autodisplayed Z-domains
    Lee, Ju-Kyung
    Gu-Yoo
    Park, Min
    Jose, Joachim
    Pyun, Jae-Chul
    EUROSENSORS XXV, 2011, 25
  • [9] Immobilization of E-coli with autodisplayed Z-domains to a surface-modified microplate for immunoassay
    Yoo, Gu
    Park, Min
    Lee, Eun-Hang
    Jose, Joachim
    Pyun, Jae-Chul
    ANALYTICA CHIMICA ACTA, 2011, 707 (01) : 142 - 147
  • [10] Co-autodisplay of Z-domains and bovine caseins on the outer membrane of E. coli
    Yoo, Gu
    Saenger, Thorsten
    Bong, Ji-Hong
    Jose, Joachim
    Kang, Min-Jung
    Pyun, Jae-Chul
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2015, 1848 (12): : 3126 - 3133