Development and Troubleshooting in Lateral Flow Immunochromatography Assays

被引:0
|
作者
Ajaikumar Sukumaran
Thushara Thomas
Riji Thomas
Rhema Elizabeth Thomas
Jofy K. Paul
D. M. Vasudevan
机构
[1] Agappe Diagnostics Limited,R&D Reagent Department
关键词
Lateral flow immunochromatography; Colloidal gold; Sensitivity; Trisodium citrate;
D O I
暂无
中图分类号
学科分类号
摘要
The development of Lateral Flow Immunochromatography Assay can be divided into two levels; standardizing membrane characteristics and optimizing molecular level immunoassay reaction between analyte and detector molecules. In the preliminary phase the reaction specificity of capture and detector antibodies with the analyte has to be checked with other techniques like ELISA. Molarity and pH of conjugation buffer have prime importance in the immunoreaction among analyte and antibodies. Epitope mapping of the capture and detector antibodies is also recommended to confirm the specificity of the assay. Standardization of membrane characteristics directly relates to the sensitivity of the assay through its porosity, hydrophobicity, protein holding/releasing capacity and wicking rate. Under optimised condition a perfect Lateral Flow Immunochromatography Assay should have high on-rate (target binding efficiency), low off-rate (target releasing efficiency) and low Cross-reactivity. In this manuscript, we share our experience, especially on developmental strategies and troubleshooting, that we have experienced during Lateral Flow Immunochromatography Assay kit development.
引用
收藏
页码:208 / 212
页数:4
相关论文
共 50 条
  • [1] Development and Troubleshooting in Lateral Flow Immunochromatography Assays
    Sukumaran, Ajaikumar
    Thomas, Thushara
    Thomas, Riji
    Thomas, Rhema Elizabeth
    Paul, Jofy K.
    Vasudevan, D. M.
    INDIAN JOURNAL OF CLINICAL BIOCHEMISTRY, 2021, 36 (02) : 208 - 212
  • [2] Development of a lateral flow immunochromatography test for the rapid detection of bovine tuberculosis
    Alonso, Natalia
    Griffa, Natanael
    Moyano, Roberto D.
    Mon, Maria L.
    Colombatti Olivieri, Maria A.
    Barandiaran, Soledad
    Martinez Vivot, Marcela
    Fiorini, Gonzalo
    Canal, Ana M.
    Santangelo, Maria P.
    Singh, Mahavir
    Romano, Maria, I
    JOURNAL OF IMMUNOLOGICAL METHODS, 2021, 491
  • [3] Development of a lateral flow immunochromatography assay for the detection of fluoroacetamide in blood samples
    Qiang Li
    Ling Yang
    Changfei Duan
    Xiaonan Wang
    Xuezhi Yu
    One Health Advances, 2 (1):
  • [4] Sensitization Strategies of Lateral Flow Immunochromatography for Gold Modified Nanomaterials in Biosensor Development
    He, Xingyue
    Hao, Tianjiao
    Geng, Hongxu
    Li, Shengzhou
    Ran, Chuanjiang
    Huo, Meirong
    Shen, Yan
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2023, 18 : 7847 - 7863
  • [5] The development and application of SERS-based lateral flow immunochromatography in the field of food safety
    Liu, Wenxi
    Wang, Hao
    Zhong, Wenhui
    Zhang, Yichun
    Liu, Yingyue
    Gao, Xibao
    Yan, Mengmeng
    Zhu, Chao
    MICROCHIMICA ACTA, 2025, 192 (04)
  • [6] The development of a novel platform for lateral flow assays.
    Jones, KD
    Cox, D
    Koscielny, M
    CLINICAL CHEMISTRY, 2004, 50 (06) : A164 - A164
  • [7] Integrated Robotic System for the Development Lateral Flow Assays
    Toan Huynh
    Anderson, Caitlin E.
    Gasperino, David J.
    Harston, Stephen P.
    Hsieh, Helen, V
    Marzan, Rosemichelle
    Williford, John R.
    Oncina, Ciela, I
    Glukhova, Veronika A.
    Cate, David M.
    Nichols, Kevin P.
    Weigl, Bernhard H.
    2019 IEEE GLOBAL HUMANITARIAN TECHNOLOGY CONFERENCE (GHTC), 2019, : 447 - 450
  • [8] Lateral flow assays
    Koczula, Katarzyna M.
    Gallotta, Andrea
    BIOSENSOR TECHNOLOGIES FOR DETECTION OF BIOMOLECULES, 2016, 60 (01): : 111 - 120
  • [9] Troubleshooting assays
    Kling, J
    SCIENTIST, 1998, 12 (05): : 19 - 19
  • [10] Development, evaluation, and application of lateral-flow immunoassay (immunochromatography) for detection of rotavirus in bovine fecal samples
    Al-Yousif, Y
    Anderson, J
    Chard-Bergstrom, C
    Kapil, S
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2002, 9 (03) : 723 - 724