Investigation of mass attenuation coefficients of water, concrete and bakelite at different energies using the FLUKA Monte Carlo code

被引:0
|
作者
Nilgun Demir
Urkiye Akar Tarim
Maria-Ana Popovici
Zehra Nur Demirci
Orhan Gurler
Iskender Akkurt
机构
[1] Faculty of Arts and Sciences,Physics Department
[2] Uludag University,Physics Department
[3] Politehnica University of Bucharest,undefined
[4] Suleyman Demirel University,undefined
关键词
Water; Bakelite; Concrete; FLUKA; Energy deposition; Mass attenuation coefficient;
D O I
暂无
中图分类号
学科分类号
摘要
The mass attenuation coefficients of water, bakelite and concrete sample defined in the simulation package were obtained using the FLUKA Monte Carlo code at 59.5, 80.9, 140.5, 356.5, 661.6, 1173.2 and 1332.5 keV photon energies. The results for the mass attenuation coefficients obtained by simulation have been compared with experimental and the theoretical ones and good agreement has been observed. The results indicate that this process can be followed to determine the data on the attenuation of gamma-rays with the several energies in other materials. Also, the deposited energy by 661.6 keV photons at several thicknesses of each media was determined as being an important data for radiation shielding studies.
引用
收藏
页码:1303 / 1307
页数:4
相关论文
共 50 条
  • [1] Investigation of mass attenuation coefficients of water, concrete and bakelite at different energies using the FLUKA Monte Carlo code
    Demir, Nilgun
    Tarim, Urkiye Akar
    Popovici, Maria-Ana
    Demirci, Zehra Nur
    Gurler, Orhan
    Akkurt, Iskender
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 298 (02) : 1303 - 1307
  • [2] Mass attenuation coefficients of human body Organs using MCNPX Monte Carlo Code
    Tekin H.O.
    Singh V.P.
    Altunsoy E.E.
    Manici T.
    Sayyed M.I.
    Tekin, Huseyin Ozan (huseyinozan.tekin@uskudar.edu.tr), 2017, Mashhad University of Medical Sciences (14) : 229 - 240
  • [3] MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3 x 3 Inch NaI(Tl) Detector and Comparison with XCOM and Monte Carlo Data
    Tekin, Huseyin Ozan
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2016, 2016
  • [4] Mass attenuation coefficient calculations of different detector crystals by means of FLUKA Monte Carlo method
    Ermis, Elif Ebru
    Celiktas, Cuneyt
    THEORETICAL AND EXPERIMENTAL STUDIES IN NUCLEAR APPLICATIONS AND TECHNOLOGY (TESNAT 2015), 2015, 100
  • [5] TESTING OF FLUKA MONTE CARLO TRANSPORT CODE FOR DIFFERENT SHIELDING CONFIGURATIONS
    Stiru, Irina-Eliza
    Radon, Torsten
    Sokolov, Alexey
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2019, 81 (02): : 215 - 220
  • [6] Testing of FLUKA Monte Carlo transport code for different shielding configurations
    Ştiru, Irina-Eliza
    Radon, Torsten
    Sokolov, Alexey
    UPB Scientific Bulletin, Series A: Applied Mathematics and Physics, 2019, 81 (02): : 215 - 220
  • [7] Simulations of microdosimetric quantities with the Monte Carlo code FLUKA for carbon ions at therapeutic energies
    Bohlen, Till T.
    Dosanjh, Manjit
    Ferrari, Alfredo
    Gudowska, Irena
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2012, 88 (1-2) : 176 - 182
  • [8] MICRODOSIMETRIC SIMULATIONS OF CARBON IONS USING THE MONTE CARLO CODE FLUKA
    Chiriotti, S.
    Conte, V.
    Colautti, P.
    Selva, A.
    Mairani, A.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 187 - 191
  • [9] Monte Carlo simulation of photons backscattering from various thicknesses of lead layered over concrete for energies 0.25–20 MeV using FLUKA code
    Ihsan A. M. Al-Affan
    Mohammad A. Z. Qutub
    Richard P. Hugtenburg
    Scientific Reports, 11
  • [10] Prevision of 89Zr production using the Monte Carlo code FLUKA
    Infantino, A.
    Cicoria, G.
    Pancaldi, D.
    Ciarmatori, A.
    Boschi, S.
    Fanti, S.
    Marengo, M.
    Mostacci, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S356 - S356