Developing a hand sizing system for a hand exoskeleton device based on the Kansei Engineering method

被引:0
|
作者
Chia-Chen Kuo
Hui-Yi Kung
Hsin-Chieh Wu
Mao-Jiun Wang
机构
[1] National Tsing Hua University,Department of Industrial Engineering and Engineering Management
[2] Tunghai University,Department of Industrial Engineering and Enterprise Information
[3] Chaoyang University of Technology,Department of Industrial Engineering and Management
关键词
Hand anthropometry; Dorsal aspect; Self-organizing map; Clustering; Sizing system; Hand exoskeleton assistive devices;
D O I
暂无
中图分类号
学科分类号
摘要
This study aimed to identify the customers’ requirements for a hand rehabilitation exoskeleton device using the Kansei Engineering approach and propose improvements. The Kansei Engineering approach was used to extract the design attributes for a hand rehabilitation exoskeleton device by conducting an in-depth interview with 3 physical therapists. The Kano questionnaire survey investigated 25 participants with hand rehabilitation experience. The Kano classification results found three attractive factors and corresponded it to the design attributes of the evaluation grid method results that were suitable (size), flexible (controllability), and light (weight). The principal component analysis results indicated three components can be considered as the improvement categories; functions, structure-texture, and appearance of the hand exoskeleton device. The new functional and structural designs were proposed in a previous study. This study collects 110 male participants’ hand anthropometric data to establish a hand sizing system as a design improvement (suitable attribute). The 3D and manual measurements were obtained for 63 hand dimensions with an open palm posture. The 14 dorsal length dimensions with three bent finger postures were also manually measured. The results showed that the MADPrecision\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\text{MAD}}_{\text{Precision}}$$\end{document} (mean absolute difference) of 3D measurement is smaller than that of manual measurement, indicating better reproducibility of 3D scanning. The MADAccuracy\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${\text{MAD}}_{\text{Accuracy}}$$\end{document} of all dimensions are within the 1 mm of the referenced ISO 20685 criteria. Significant differences were found in the 14 dorsal hand length, showing that databases should explicitly state the aspect (dorsal or palmar) where dimensions have been of measurement. The 77 hand dimensions were taken into consideration to develop a hand sizing system using the clustering results. The two-level self-organizing map method was performed and 3 handshape types and 8 sizes were extracted. The coverage rate of the sizing system was over 85%. These results provide useful information for designing and manufacturing for hand-related products.
引用
收藏
页码:14395 / 14407
页数:12
相关论文
共 50 条
  • [1] Developing a hand sizing system for a hand exoskeleton device based on the Kansei Engineering method
    Kuo, Chia-Chen
    Kung, Hui-Yi
    Wu, Hsin-Chieh
    Wang, Mao-Jiun
    [J]. JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2020, 14 (11) : 14395 - 14407
  • [2] Design and Control of an Exoskeleton Based Device for Hand Rehabilitation
    Hajiyan, Mohammadhossein
    Biglarbegian, Mohammad
    Mahmud, Shohel
    Abdullah, Hussein A.
    [J]. 2017 IEEE 5TH INTERNATIONAL SYMPOSIUM ON ROBOTICS AND INTELLIGENT SENSORS (IRIS), 2017, : 91 - 97
  • [3] Rapid Prototyping in Engineering Education: Developing a Hand Exoskeleton for Personalized Rehabilitation
    Ciceri, Mirko
    Gauterio, Marco
    Scaccabarozzi, Stefano
    Paz, Jose Angel Santos
    Garcia-Carmona, Rodrigo
    Aruanno, Beatrice
    Covarrubias, Mario
    [J]. Computer-Aided Design and Applications, 2024, 21 (03): : 474 - 486
  • [4] Design of a Hand Exoskeleton Rehabilitation Device
    Bi, Qian
    Yang, Canjun
    [J]. MECHATRONICS AND MATERIALS PROCESSING I, PTS 1-3, 2011, 328-330 : 1778 - 1783
  • [5] HANDEXOS: towards an exoskeleton device for the rehabilitation of the hand
    Chiri, A.
    Giovacchini, F.
    Vitiello, N.
    Cattin, E.
    Roccella, S.
    Vecchi, F.
    Carrozza, M. C.
    [J]. 2009 IEEE-RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, 2009, : 1106 - 1111
  • [6] Study on an exoskeleton hand function training device
    [J]. Yu, Hongliu (yhl98@hotmail.com), 2016, West China Hospital, Sichuan Institute of Biomedical Engineering (33):
  • [7] Development of a Hand Exoskeleton System for Quantitative Analysis of Hand Functions
    Lee, Jeongsoo
    Lee, Minhyuk
    Bae, Joonbum
    [J]. JOURNAL OF BIONIC ENGINEERING, 2018, 15 (05) : 783 - 794
  • [8] Design of a Wearable Hand Exoskeleton System for Evaluation of Hand Functions
    Lee, Jeongsoo
    Kim, Suin
    Park, Wookeun
    Bae, Joonbum
    [J]. 2017 14TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2017, : 578 - 579
  • [9] Development of a Hand Exoskeleton System for Quantitative Analysis of Hand Functions
    Jeongsoo Lee
    Minhyuk Lee
    Joonbum Bae
    [J]. Journal of Bionic Engineering, 2018, 15 : 783 - 794
  • [10] Flexohand: A Hybrid Exoskeleton-Based Novel Hand Rehabilitation Device
    Ahmed, Tanvir
    Assad-Uz-Zaman, Md
    Islam, Md Rasedul
    Gottheardt, Drew
    McGonigle, Erin
    Brahmi, Brahim
    Rahman, Mohammad Habibur
    [J]. MICROMACHINES, 2021, 12 (11)