Resistive plate chambers in positron emission tomography

被引:0
|
作者
Paulo Crespo
Alberto Blanco
Miguel Couceiro
Nuno C. Ferreira
Luís Lopes
Paulo Martins
Rui Ferreira Marques
Paulo Fonte
机构
[1] University of Coimbra,LIP
[2] University of Coimbra, Laboratório de Instrumentação e Física Experimental de Partículas, Rua Larga, Physics Department
[3] ISEC - Instituto Superior de Engenharia de Coimbra,Physics Department
[4] University of Coimbra,IBILI
[5] University of Coimbra, Instituto Biomédico de Investigação da Luz e da Imagem, Faculty of Medicine
关键词
Root Mean Square Error; Resistive Plate Chamber; Noise Equivalent Count Rate; Pickup Electrode; Charge Division;
D O I
暂无
中图分类号
学科分类号
摘要
Resistive plate chambers (RPC) were originally deployed for high energy physics. Realizing how their properties match the needs of nuclear medicine, a LIP team proposed applying RPCs to both preclinical and clinical positron emission tomography (RPC-PET). We show a large-area RPC-PET simulated scanner covering an axial length of 2.4m —slightly superior to the height of the human body— allowing for whole-body, single-bed RPC-PET acquisitions. Simulations following NEMA (National Electrical Manufacturers Association, USA) protocols yield a system sensitivity at least one order of magnitude larger than present-day, commercial PET systems. Reconstruction of whole-body simulated data is feasible by using a dedicated, direct time-of-flight-based algorithm implemented onto an ordered subsets estimation maximization parallelized strategy. Whole-body RPC-PET patient images following the injection of only 2mCi of 18-fluorodesoxyglucose (FDG) are expected to be ready 7 minutes after the 6 minutes necessary for data acquisition. This compares to the 10-20mCi FDG presently injected for a PET scan, and to the uncomfortable 20-30minutes necessary for its data acquisition. In the preclinical field, two fully instrumented detector heads have been assembled aiming at a four-head-based, small-animal RPC-PET system. Images of a disk-shaped and a needle-like 22Na source show unprecedented sub-millimeter spatial resolution.
引用
收藏
相关论文
共 50 条
  • [1] Resistive plate chambers in positron emission tomography
    Crespo, Paulo
    Blanco, Alberto
    Couceiro, Miguel
    Ferreira, Nuno C.
    Lopes, Luis
    Martins, Paulo
    Marques, Rui Ferreira
    Fonte, Paulo
    EUROPEAN PHYSICAL JOURNAL PLUS, 2013, 128 (07):
  • [2] Resistive plate chambers for tomography and radiography
    Thomay, C.
    Baesso, P.
    Cussans, D.
    Davies, J.
    Glaysher, P.
    Quillin, S.
    Robertson, S.
    Steer, C.
    Vassallo, C.
    Velthuis, J.
    GEOSCIENTIFIC INSTRUMENTATION METHODS AND DATA SYSTEMS, 2012, 1 (02) : 235 - 238
  • [3] MESH CHAMBERS FOR POSITRON EMISSION TOMOGRAPHY
    LANZA, RC
    OSBORNE, LS
    HOLMAN, BL
    ZIMMERMAN, RE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 482 - 485
  • [4] Muon scattering tomography with resistive plate chambers.
    Baesso, Paolo
    Cussans, David
    Glaysher, Paul
    Thomay, Christian
    Velthuis, Jaap
    Vassallo, Caroline
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 59 - 61
  • [5] Muon tomography with Resistive Plate Chambers for geological characterization
    Sarmento, Raul
    Castro, Alberto Blanco
    Caldeira, Bento
    Tome, Bernardo
    Loureiro, Custodio
    Clemencio, Filomena
    Alexandre, Isabel
    Costa, Joao
    Matos, Joao
    Saraiva, Joao
    Silva, Jorge
    Borges, Jose
    Cazon, Lorenzo
    Afonso, Luis
    Lopes, Luis
    Duarte, Magda
    Pinto, Marco
    Pimenta, Mario
    Bezzeghoud, Mourad
    Dobrilla, Paolo
    Assis, Pedro
    Teixeira, Pedro
    Oliveira, Rui
    Andringa, Sofia
    Pais, Vanessa
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1060
  • [6] Time-of-Flight Positron Emission Tomography with Resistive Plate Chamber Detectors: An Unlikely but Promising Approach
    Couceiro, M.
    Crespo, P.
    Blanco, A.
    Ferreira, N. C.
    Mendes, L.
    Ferreira Marques, R.
    Fonte, P.
    ACTA PHYSICA POLONICA A, 2015, 127 (05) : 1453 - 1461
  • [7] HIGH-DENSITY AVALANCHE CHAMBERS FOR POSITRON EMISSION TOMOGRAPHY
    MANFRASS, P
    ENGHARDT, W
    FROMM, WD
    WOHLFARTH, D
    HOHMUTH, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 904 - 907
  • [8] High-density avalanche chambers for positron emission tomography
    Manfrass, P.
    Enghardt, W.
    Fromm, W.D.
    Wohlfarth, D.
    Hohmuth, K.
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 904 - 907
  • [9] The physics of Resistive Plate Chambers
    Riegler, W
    Lippmann, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 86 - 90
  • [10] Resistive plate chambers in ATLAS
    DiCiaccio, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 384 (01): : 222 - 224