Proficiency test of pH, conductivity and dissolved oxygen concentration field measurements in river water

被引:0
|
作者
Teemu Näykki
Mirja Leivuori
Katarina Björklöf
Ritva Väisänen
Marko Laine
Tero Väisänen
Ivo Leito
机构
[1] Finnish Environment Institute (SYKE),Environmental Measurement and Testing Laboratory
[2] Finnish Environment Institute (SYKE),Reference Laboratory
[3] Finnish Meteorological Institute,Environmental Measurement and Testing Laboratory
[4] Finnish Environment Institute (SYKE),Institute of Chemistry
[5] University of Tartu,undefined
来源
关键词
Proficiency test; pH; Conductivity; Dissolved oxygen; Sensor; Field measurement; In situ;
D O I
暂无
中图分类号
学科分类号
摘要
In 2013, Proftest SYKE organised the first proficiency test (PT) in Finland for field measurements of temperature, conductivity, dissolved oxygen concentration, oxygen saturation and pH value in river water. The aim was to pilot the organisation of an in situ proficiency test—particularly, how to select the test location—and how to assess the homogeneity and stability of the measurement site and the water to be tested. The focus was also to evaluate the suitability of the common field sensors used for water analysis, as well as the comparability of the results between the instruments under field conditions. The overall application of quality assurance procedures was also surveyed. This paper deals with the results, findings and recommendations for the measurement of pH, conductivity and dissolved oxygen concentration. In total, nine participants with 16 sensors took part in the proficiency test. For the evaluation of the performance of each participant, z scores were calculated allowing 3 % to 8 % deviation from the assigned value. The standard deviation of the participant’s results was lower than organiser expected, and 80 % of the results for pH, 79 % for conductivity and 69 % for dissolved oxygen concentration were regarded as satisfactory. According to the results, the most challenging measurement was for dissolved oxygen with a Clark cell-type measurement principle based on electrochemical reaction. All sensors tested in the PT were less than 5 years, old and they were calibrated according to the manufacturer’s instructions. None of the participants had estimated measurement uncertainty for their sensor measurements. In addition, internal and external quality assurance protocols were usually lacking.
引用
收藏
页码:259 / 268
页数:9
相关论文
共 50 条
  • [1] Proficiency test of pH, conductivity and dissolved oxygen concentration field measurements in river water
    Naykki, Teemu
    Leivuori, Mirja
    Bjorklof, Katarina
    Vaisanen, Ritva
    Laine, Marko
    Vaisanen, Tero
    Leito, Ivo
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2014, 19 (04) : 259 - 268
  • [2] MEASUREMENTS OF DISSOLVED OXYGEN CONCENTRATION AT WATER SURFACE
    Janzen, Johannes Gerson
    Schulz, Harry Edmar
    Lamon, Antonio Wagner
    [J]. ENGENHARIA SANITARIA E AMBIENTAL, 2008, 13 (03) : 278 - 283
  • [4] Dissolved Oxygen Concentration Prediction in the Pearl River Estuary with Deep Learning for Driving Factors Identification: Temperature, pH, Conductivity, and Ammonia Nitrogen
    Liang, Xu
    Jian, Zhanqiang
    Tan, Zhongheng
    Dai, Rui
    Wang, Haozhi
    Wang, Jun
    Qiu, Guanglei
    Chang, Ming
    Li, Tiexiang
    [J]. Water (Switzerland), 2024, 16 (21)
  • [5] The vertical profile of water temperature, dissolved oxygen, pH and conductivity in Lake Burdur, Turkey
    Gulle, Iskender
    Turna, Ismail Ibrahim
    Guclu, Salim Serkan
    Kucuk, Fahrettin
    Gulle, Pinar
    Guclu, Zekiye
    [J]. SU URUNLERI DERGISI, 2008, 25 (04): : 283 - 287
  • [7] CONCENTRATION AND SPECIATION OF DISSOLVED SUGARS IN RIVER WATER
    SWEET, MS
    PERDUE, EM
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1982, 16 (10) : 692 - 698
  • [8] in situ interlaboratory comparisons for dissolved oxygen concentration and pH
    Lauri Jalukse
    Viktor Vabson
    Ivo Leito
    [J]. Accreditation and Quality Assurance, 2006, 10 : 562 - 564
  • [9] THE CONCENTRATION AND SPECIATION OF DISSOLVED SUGARS IN RIVER WATER
    SWEET, M
    PERDUE, EM
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 180 (AUG): : 158 - ENVR
  • [10] in situ interlaboratory comparisons for dissolved oxygen concentration and pH
    Jalukse, L
    Vabson, V
    Leito, I
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2006, 10 (10) : 562 - 564