Development of a test strip reader for a lateral flow membrane-based immunochromatographic assay

被引:0
|
作者
Suhyeon Kim
Je-Kyun Park
机构
[1] LG Electronics Institute of Technology,Bio Electronics Group
[2] Korea Advanced Institute of Science and Technology,Department of BioSystems
关键词
test strip reader; immunoassay; immunochromatographic assay; lateral flow assay;
D O I
暂无
中图分类号
学科分类号
摘要
A low-cost, simple strip reader system using a linear movement mechanism of CD-ROM deck has been developed to characterize a lateral flow membrane-based immunochromatographic assay. The test strip reader was assembled by a CD-ROM deck and home-made optical head especially designed for immunoassays. The optical head for detecting reflected light from the test strip surface consists of green light-emitting diode, large area silicon photodiode, and anodized aluminum mounting block providing a slit structure for cutting light from the LED. The stepping motor of the deck was operated in the full step mode, whose distance of each reading point is about 0.15 mm. The performance of the strip reader was tested by analysis of HBV (hepatitis B virus) antigen test kit. This strip reader can be useful for inexpensive, disposable, and membrane-based assays that provide visual evidence of the presence of an analyte in a liquid sample.
引用
收藏
页码:127 / 131
页数:4
相关论文
共 50 条
  • [1] Development of a test strip reader for a lateral flow membrane-based immunochromatographic assay
    Kim, S
    Park, JK
    [J]. BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2004, 9 (02) : 127 - 131
  • [2] Membrane-based lateral flow immunochromatographic strip with nanoparticles as reporters for detection: A review
    Huang, Xiaolin
    Aguilar, Zoraida P.
    Xu, Hengyi
    Lai, Weihua
    Xiong, Yonghua
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 75 : 166 - 180
  • [3] A Lateral Flow Immunochromatographic Assay (LFIA) Strip Reader Based on Scheduler and 8051 IP Core
    Wei, Jian Chong
    Gao, Yue Ming
    Li, Guo Qing
    Wang, Zhi Jiong
    Vai, Mang I.
    Mak, Peng Un
    Du, Min
    Pun, Sio Hang
    [J]. AUTOMATIKA, 2016, 57 (04) : 1079 - 1088
  • [4] Development of a Smartphone-Based Fluorescent Immunochromatographic Assay Strip Reader
    Zheng, Qi
    Wu, Huihuang
    Jiang, Haiyan
    Yang, Jiejie
    Gao, Yueming
    [J]. SENSORS, 2020, 20 (16) : 1 - 12
  • [5] Development of an immunochromatographic lateral flow strip test for the rapid detection of diclofenac in medicinal wine
    Yang, Xingdong
    Wan, Yinbiao
    Yang, Jifei
    Sun, Zhongke
    Chu, Cuiwei
    Yue, Zonghao
    Li, Lili
    Hu, Xiaofei
    [J]. FOOD AND AGRICULTURAL IMMUNOLOGY, 2020, 31 (01) : 205 - 216
  • [6] Development of an immunochromatographic lateral flow test strip for detection of β-adrenergic agonist Clenbuterol residues
    Zhang, G. P.
    Wang, X. N.
    Yang, J. F.
    Yang, Y. Y.
    Xing, G. X.
    Li, Q. M.
    Zhao, D.
    Chai, S. J.
    Guo, J. Q.
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 312 (1-2) : 27 - 33
  • [7] Development and evaluation of a rapid lateral flow immunochromatographic strip assay for screening 19-nortestosterone
    Liu, Liqiang
    Peng, Chifang
    Jin, Zhengyu
    Xu, Chuanlai
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (08) : 861 - 866
  • [8] Mobile phase blocking chemistries for Nylon membrane-based immunochromatographic lateral flow assays.
    Wilkinson, J
    Arnold, TE
    [J]. CLINICAL CHEMISTRY, 2002, 48 (06) : A171 - A171
  • [9] An Immunochromatographic Lateral Flow Strip Test for the Rapid Detection of Danofloxacin in Milk
    Xingdong Yang
    Yinbiao Wang
    Jifei Yang
    Zhongke Sun
    Zonghao Yue
    Lili Li
    Le He
    Xiaofei Hu
    [J]. Food Analytical Methods, 2019, 12 : 2430 - 2437
  • [10] An Immunochromatographic Lateral Flow Strip Test for the Rapid Detection of Danofloxacin in Milk
    Yang, Xingdong
    Wang, Yinbiao
    Yang, Jifei
    Sun, Zhongke
    Yue, Zonghao
    Li, Lili
    He, Le
    Hu, Xiaofei
    [J]. FOOD ANALYTICAL METHODS, 2019, 12 (11) : 2430 - 2437