Tolerance of cavitation damages in developing requirements for spillway surfaces at the irgana hydroproject

被引:0
|
作者
Abdarakhmanov M.A. [1 ]
Kostin V.V. [1 ]
Nikulin D.A. [2 ]
Shvainshtein A.M. [3 ]
Korotkov N.N. [3 ]
Shkuropat A.G. [3 ]
机构
[1] Irgana HPP, Daghestan
[2] JSC Lengidroproekt, St. Petersburg
[3] JSC VNIIG Im. B. E. Vedeneeva, St. Petersburg
关键词
Cavitation damages; Flow parameters; Irgana hydroproject; Permissible height of irregularities; Rectangular projections; Surfaces of steeply inclined section of spillway in contact with flow;
D O I
10.1007/s10749-011-0231-7
中图分类号
学科分类号
摘要
Basic information on the in-service tunnel spillway at the Irgana HPP, and also requirements for smoothing irregularities in its surfaces in contact with the flow are presented. A method is proposed for determination of requirements for the surface of the spillway with a tolerance for cavitation damages. Results of experimental investigations and analyses are presented. © 2011 Springer Science + Business Media, Inc.
引用
收藏
页码:100 / 108
页数:8
相关论文
共 1 条
  • [1] Cavitation damages on solid surfaces in suspensions containing spherical and irregular microparticles
    Chen Haosheng
    Wang Jiadao
    Chen Darong