摘要
Ti—6Al—7Nb and Ti—5Al—2Nb—1Ta alloys were implanted with N+ ions with an ion energy of 75 keV at a dose rate of 1 × 1017 and 1 × 1018 ions cm−2. Open circuit potential (OCP) and potentiodynamic cyclic polarization measurements were carried out on the titanium alloys in Hanks solution to assess their corrosion resistance. The tendency for repassivation is higher in the case of implanted alloys than in untreated alloys owing to the formation of stable passive films. The impedance data showed a decrease in the double layer capacitance and an increase in the charge transfer resistance of the treated alloys. Nitrogen ion implanted Ti—6Al—7Nb was found to be more corrosion resistant than implanted Ti—5Al—2Nb—1Ta alloy.
引用
收藏
页码:271 / 276
页数:5
相关论文
共 50 条
  • [1] Effect of N+ ion implantation on the corrosion behaviour of Ti-6Al-7Nb and Ti-5Al-2Nb-1Ta orthopaedic alloys in Hanks solution
    Lakshmi, SG
    Tamilselvi, S
    Rajendran, N
    Arivuoli, D
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2004, 34 (03) : 271 - 276
  • [2] In vitro corrosion behaviour of Ti-5Al-2Nb-1Ta alloy in Hanks solution
    Tamilselvi, S.
    Rajendran, N.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2007, 58 (04): : 285 - 289
  • [3] Thermal Stability of Ti6242S and Ti–6Al–7Nb Alloys
    M. S. Kalienko
    A. V. Zhelnina
    A. V. Volkov
    P. E. Panfilov
    Russian Metallurgy (Metally), 2022, 2022 : 1211 - 1217
  • [4] In vitro corrosion behaviour of plasma nitrided Ti-6Al-7Nb orthopaedic alloy in Hanks solution
    Lakshmi, S. Gokul
    Raman, V.
    Rajendran, N.
    Babi, M. A. K.
    Arivuoli, D.
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2003, 4 (05) : 415 - 418
  • [5] Mechanical properties and corrosion resistance of Ti–6Al–7Nb alloy dental castings
    E. Kobayashi
    T.J. Wang
    H. Doi
    T. Yoneyama
    H. Hamanaka
    Journal of Materials Science: Materials in Medicine, 1998, 9 : 567 - 574
  • [6] Comparison between the machinability of different titanium alloys (Ti–6Al–4V and Ti–6Al–7Nb) employing the multi-objective optimization
    Amanda Oliveira Mello
    Robson Bruno Dutra Pereira
    Carlos Henrique Lauro
    Lincoln Cardoso Brandão
    J. Paulo Davim
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2021, 43
  • [7] Effects of pH and Chloride Concentration on Corrosion Behavior of Duplex Stainless Steel and Titanium Alloys Ti 6Al 2Nb 1Ta 1Mo at Elevated Temperature for Pump Impeller Applications
    Ahmed, Aymen A.
    Burjes, Ammar Yaseen
    Elias, Marwan Zuhair
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2022, 21 (06): : 454 - 465
  • [8] Electrochemical behaviour and characterisation of plasma nitrided Ti-5Al-2Nb-1Ta orthopedic alloy in Hanks solution
    Lakshmi, SG
    Tamilselvi, S
    Rajendran, N
    Babi, MAK
    Arivuoli, D
    SURFACE & COATINGS TECHNOLOGY, 2004, 182 (2-3): : 287 - 293
  • [9] Enhanced wear resistance of Ti-5Al-2Nb-1Ta orthopaedic alloy by nitrogen ion implantation
    Lakshmi, SG
    Arivuoli, D
    TRIBOLOGY INTERNATIONAL, 2006, 39 (06) : 548 - 552
  • [10] The Effect of Fluoride Ions on the Corrosion Behaviour of Ti Metal, and Ti6-Al-7Nb and Ti-6Al-4V Alloys in Artificial Saliva
    Milosev, Ingrid
    Kapun, Barbara
    Selih, Vid Simon
    ACTA CHIMICA SLOVENICA, 2013, 60 (03) : 543 - 555