Blood T1* correction increases accuracy of extracellular volume measurements using 3T cardiovascular magnetic resonance: Comparison of T1 and T1* maps

被引:0
|
作者
Yongning Shang
Xiaochun Zhang
Xiaoyue Zhou
Andreas Greiser
Zhengwei Zhou
Debiao Li
Jian Wang
机构
[1] Third Military Medical University,Department of Radiology, Southwest Hospital
[2] MR Collaboration,Biomedical Imaging Research Institute
[3] Siemens Healthcare Ltd.,Department of Bioengineering
[4] Siemens Healthcare GmbH,undefined
[5] Cedars-Sinai Medical Center,undefined
[6] Los Angeles,undefined
[7] University of California Los Angeles,undefined
[8] Los Angeles,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The goals were to compare the differences between ECVL (extracellular volume derived from myocardial T1 and blood T1), ECVc (combination of myocardial T1 and blood T1*), and ECVnL (derived from myocardium T1* and blood T1*), and to explore the diagnostic accuracy of these factors for discriminating between controls and patients. The Modified Look-Locker Inversion Recovery sequence was performed in 42 subjects to generate both T1 and T1* maps. Native and post-contrast T1 values for myocardium and blood pool were obtained, and ECVL, ECVc, and ECVnL were then calculated. The global ECVc values were smaller than the ECVL values (0.006, 2.11%, p < 0.001) and larger than the ECVnL values (0.06, 21.6%, p < 0.001) in all participants. The ECVc led to a 4–6% increase in the AUC value and a 24–32% reduction in the sample size to differentiate between the controls and other patients when compared with the ECVL. Blood T1* correction can improve the precision of blood T1 values and can consequently increase the accuracy of the extracellular volume fraction measurement. The ECVc can be used to improve diagnostic accuracy and reduce the sample size required for a clinical study.
引用
收藏
相关论文
共 50 条
  • [1] Blood T1*correction increases accuracy of extracellular volume measurements using 3T cardiovascular magnetic resonance: Comparison of T1 and T1*maps
    Shang, Yongning
    Zhang, Xiaochun
    Zhou, Xiaoyue
    Greiser, Andreas
    Zhou, Zhengwei
    Li, Debiao
    Wang, Jian
    SCIENTIFIC REPORTS, 2018, 8
  • [2] Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
    Teixeira, Tiago
    Hafyane, Tarik
    Stikov, Nikola
    Akdeniz, Cansu
    Greiser, Andreas
    Friedrich, Matthias G.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18 : 1 - 12
  • [3] Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
    Tiago Teixeira
    Tarik Hafyane
    Nikola Stikov
    Cansu Akdeniz
    Andreas Greiser
    Matthias G. Friedrich
    Journal of Cardiovascular Magnetic Resonance, 18
  • [4] Effects of Blood T1 on Extracellular Volume Calculation
    Codreanu, Andrei
    Ferry, Pauline
    Beaumont, Marine
    Marie, Pierre-Yves
    JACC-CARDIOVASCULAR IMAGING, 2014, 7 (08) : 848 - 849
  • [5] A T1 SPACE WITH NO CLOSED POINTS, AND A T1 LOCALE WHICH IS NOT T1
    MURCHISTON, GS
    STANLEY, MG
    MATHEMATICAL PROCEEDINGS OF THE CAMBRIDGE PHILOSOPHICAL SOCIETY, 1984, 95 (MAY) : 421 - 422
  • [6] T1ρ magnetic resonance fingerprinting
    Wyatt, Cory R.
    Barbara, Thomas M.
    Guimaraes, Alexander R.
    NMR IN BIOMEDICINE, 2020, 33 (05)
  • [7] Blood T1 measurements using slice-interleaved T1 mapping (STONE) sequence
    Steven Bellm
    Long Ngo
    Jihye Jang
    Sophie Berg
    Kraig V Kissinger
    Beth Goddu
    Warren J Manning
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [8] Myocardial and blood T1 quantification in normal volunteers at 3T
    Christopher T Sibley
    Justin Huang
    Martin Ugander
    Abiola Oki
    Jing Han
    Marcelo S Nacif
    Andreas Greiser
    Daniel R Messroghli
    Peter Kellman
    Andrew E Arai
    David A Bluemke
    Songtao Liu
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [9] In Vivo Blood T1 Measurements at 1.5 T, 3 T, and 7 T
    Zhang, X.
    Petersen, E. T.
    Ghariq, E.
    De Vis, J. B.
    Webb, A. G.
    Teeuwisse, W. M.
    Hendrikse, J.
    van Osch, M. J. P.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) : 1082 - 1086
  • [10] Myocardial T1 responds to adenosine - normal values of stress T1 reactivity at 1.5T and 3T
    Alexander Liu
    Rohan S Wijesurendra
    Jane M Francis
    Matthew D Robson
    Stefan Neubauer
    Stefan K Piechnik
    Vanessa M Ferreira
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)