Fouling in reverse osmosis (RO) membrane in water recovery from secondary effluent: a review

被引:0
|
作者
Santosh Raj Pandey
Veeriah Jegatheesan
Kanagaratnam Baskaran
Li Shu
机构
[1] Deakin University,School of Engineering
关键词
Reverse osmosis; Secondary effluent; Water recovery; Potential fouling water quality parameters; Membrane fouling; Pre-treatments;
D O I
暂无
中图分类号
学科分类号
摘要
Reverse osmosis (RO) is the most preferable process for water recovery from secondary effluent (SE) because of its higher rejection of impurities with lower associated cost and higher quality of product. Fouling still is a major challenge during the water recovery due to higher contaminant loadings in SE and high rejection capability of this membrane. The presence of suspended solids, colloidal and organic matters, and high level of biological activities in SE further elevate fouling potentiality. This review was performed to identify major foulants causing hindrance in sustainable application of reverse osmosis and to present available pre-treatment options for these foulants. There are four fouling types present in RO namely; bio-fouling, inorganic/scaling, organic, and particulate fouling. Among them; bio-fouling is less understood but dominant since the pre-treatment options are not well developed. Other fouling mechanisms have been overcome by well developed pre-treatments. The major foulants for RO are dissolved and macromolecular organic substances, sparingly soluble inorganic compounds, colloidal and suspended particles, and micro-organisms. Some of these potential fouling water quality parameters (PFWQPs) are interrelated with each others such as electrical conductivity is a surrogate measure of total dissolved solids with established stable relationship. Most of these PFWQPs such as total suspended solids, turbidity, chemical oxygen demand can be removed by conventional pre-treatment; some such as colloidal particles and micro-organisms by modern options and even others such as endocrine disrupting compounds, pharmaceutical and personal care products are still challenging for current pre-treatments. These foulants need to be identified properly to integrate appropriate pre-treatments for minimizing fouling potentiality to increase water recovery at minimal costs.
引用
收藏
页码:125 / 145
页数:20
相关论文
共 50 条
  • [1] Fouling in reverse osmosis (RO) membrane in water recovery from secondary effluent: a review
    Pandey, Santosh Raj
    Jegatheesan, Veeriah
    Baskaran, Kanagaratnam
    Shu, Li
    [J]. REVIEWS IN ENVIRONMENTAL SCIENCE AND BIO-TECHNOLOGY, 2012, 11 (02) : 125 - 145
  • [2] Recovery of cooling tower blowdown water through reverse osmosis (RO): review of water parameters affecting membrane fouling and pretreatment schemes
    Ahmed, Jawwad
    Jamal, Yousuf
    Shujaatullah, Muhammad
    [J]. DESALINATION AND WATER TREATMENT, 2020, 189 : 9 - 17
  • [3] Fouling mechanisms and primary foulant constituents in reverse osmosis membrane reclamation of a petrochemical secondary effluent
    Li, Haigang
    Yu, Ping
    Luo, Yunbai
    [J]. DESALINATION AND WATER TREATMENT, 2015, 54 (12) : 3200 - 3210
  • [4] Performance of reverse osmosis ( RO) for water recovery from permeates of membrane bio- reactor ( MBR)
    Pandey, Santosh Raj
    Jegatheesan, Veeriah
    Baskaran, Kanagaratnam
    Shu, Li
    Muthukumaran, Shobha
    [J]. DESALINATION AND WATER TREATMENT, 2014, 52 (4-6) : 600 - 611
  • [5] Design of reverse osmosis (RO) water treatment networks subject to fouling
    See, HJ
    Wilson, DI
    Vassiliadis, VS
    Parks-, GT
    [J]. WATER SCIENCE AND TECHNOLOGY, 2004, 49 (02) : 263 - 270
  • [6] REVERSE-OSMOSIS ON SECONDARY SEWAGE EFFLUENT - EFFECT OF RECOVERY
    WECHSLER, R
    [J]. WATER RESEARCH, 1977, 11 (04) : 379 - 385
  • [7] A review of reverse osmosis membrane fouling and control strategies
    Jiang, Shanxue
    Li, Yuening
    Ladewig, Bradley P.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 595 : 567 - 583
  • [8] Treatability of organic fractions derived from secondary effluent by reverse osmosis membrane
    Hu, JY
    Ong, SL
    Shan, JH
    Kang, JB
    Ng, WJ
    [J]. WATER RESEARCH, 2003, 37 (19) : 4801 - 4809
  • [9] Piezoelectric reverse osmosis (RO) membrane: Fabrication and anti-fouling effect
    Fu, Jia Shen
    Sim, Lee Nuang
    Su, Yu Ping
    Chong, Tzyy Haur
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2024, 695
  • [10] Assessment of biological activated carbon treatment to control membrane fouling in reverse osmosis of secondary effluent for reuse in irrigation
    Pramanik, Biplob Kumar
    Roddick, Felicity A.
    Fan, Linhua
    Jeong, Sanghyun
    Vigneswaran, Saravanamuth
    [J]. DESALINATION, 2015, 364 : 90 - 95