Improvements of an oscillatory squeezing flow rheometer for small elasticity measurements of liquids

被引:0
|
作者
Shinri Sakai
机构
[1] Tokyo Institute of Technology,
[2] Seiko Epson Corporation,undefined
来源
Rheologica Acta | 2004年 / 44卷
关键词
Complex modulus; Squeezing rheometer; Squeezing flow; Harmonics correction; Compliance correction;
D O I
暂无
中图分类号
学科分类号
摘要
Dilute dispersions and polymer solutions used as functional fluids or operation fluids are required to be controlled in an extremely high quality level in the semiconductor industry or MEMS (Micro Mechanical Electric System) devices, such as inkjet print heads and micro pumps. Many of the quality items depend on microscopic state of dispersion or solution stem from mutual interactions among the dispersed particles and solved polymers; hence, close investigations of these complex interactions are of great concern for developments of highly functional fluids and micro fluidic devices. Here, some great improvements are presented on a random oscillatory squeezing flow rheometer to detect subtle rheological properties arise as results of interactions between micro solid particles dispersed in liquids. To detect subtle elasticity within fundamentally viscous liquids, very small phase difference from the viscous response has to be measured, and for this reason effects from three major sources (sensor nonlinearity, nonlinear squeeze flow response, and instrument compliance) that give phase errors and noises as well as fluid inertia are completely compensated by data processing, achieving sensitivity for subtle dynamic modulus G′ to the extent of G′/G ∼0.001. As examples of the dilute dispersions, water dispersions of monodisperse acrylic latex were measured and detections of dynamic modulus G′ of 10−3 Pa at 100 Hz were demonstrated.
引用
收藏
页码:16 / 28
页数:12
相关论文
共 50 条
  • [1] Improvements of an oscillatory squeezing flow rheometer for small elasticity measurements of liquids
    Sakai, S
    RHEOLOGICA ACTA, 2004, 44 (01) : 16 - 28
  • [2] Application of squeezing flow technique for viscosity measurements of polymer liquids
    Kotomin, SV
    Kulichikhin, VG
    VYSOKOMOLEKULYARNYE SOEDINENIYA SERIYA A & SERIYA B, 1996, 38 (12): : 2079 - 2083
  • [3] LUBRICATED SQUEEZING FLOW - A NEW BIAXIAL EXTENSIONAL RHEOMETER
    CHATRAEI, S
    MACOSKO, CW
    WINTER, HH
    JOURNAL OF RHEOLOGY, 1981, 25 (04) : 467 - 467
  • [4] SQUEEZING FLOW OF ELASTIC LIQUIDS
    MCCLELLAND, MA
    FINLAYSON, BA
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 1983, 13 (02) : 181 - 201
  • [5] Oscillatory squeezing flow of a biological material
    Nhan Phan-Thien
    Simin Nasseri
    Lynne E. Bilston
    Rheologica Acta, 2000, 39 : 409 - 417
  • [6] Oscillatory squeezing flow of a biological material
    Phan-Thien, N
    Nasseri, S
    Bilston, LE
    RHEOLOGICA ACTA, 2000, 39 (04) : 409 - 417
  • [7] Measurements of vocal fold elasticity using the linear skin rheometer
    Hess, Markus M.
    Mueller, Frank
    Kobler, James B.
    Zeitels, Steven M.
    Goodyer, Eric
    FOLIA PHONIATRICA ET LOGOPAEDICA, 2006, 58 (03) : 207 - 216
  • [8] The oscillatory squeeze flow rheometer: comprehensive theory and a new experimental facility
    D. Bell
    D. M. Binding
    K. Walters
    Rheologica Acta, 2006, 46 : 111 - 121
  • [9] Technical note: correcting for shear strain in an oscillatory squeeze flow rheometer
    David Konigsberg
    Timothy M. Nicholson
    Peter J. Halley
    Kyung Hyun Ahn
    Rheologica Acta, 2014, 53 : 103 - 107
  • [10] Technical note: Correcting for shear strain in an oscillatory squeeze flow rheometer
    Konigsberg, David (d.konigsberg@uq.edu.au), 1600, Springer Verlag (53):