The use of combined T2-weighted and FLAIR synthetic magnetic resonance images to improve white matter region contrast: a feasibility study

被引:0
|
作者
Yasuhiro Fujiwara
Yumi Inoue
Masayuki Kanamoto
Shota Ishida
Toshiki Adachi
Hirohiko Kimura
机构
[1] Kumamoto University,Department of Medical Imaging, Faculty of Life Sciences
[2] Kumamoto University,Course of Radiological Science, School of Health Sciences
[3] University of Fukui Hospital,Radiological Center
[4] University of Fukui,Department of Radiology
来源
关键词
Magnetic resonance imaging (MRI); Synthetic MRI; Quantitative MRI; White matter lesion; Multiple sclerosis;
D O I
暂无
中图分类号
学科分类号
摘要
Synthetic magnetic resonance imaging (MRI) allows the production of images with any contrast from a single scan after quantification. The combined T2-weighted image (T2WI) and fluid-attenuated inversion recovery (FLAIR) image is expected to have an improved contrast between the normal-appearing white matter (WM) and WM lesion (WML). The purpose of this study was to determine whether optimal T2 contrast-weighted images (SyFLAIR3) comprising the combined T2WI and FLAIR image generated using synthetic MRI could improve contrast in the WM region. Numerical simulations were performed to estimate the contrast-to-noise ratio (CNR) between the WM and WML and cerebrospinal fluid (CSF) ratio at any echo time (TE) using SyFLAIR3. The CNR and CSF ratio for SyFLAIR3 was compared with those for FLAIR and double inversion recovery (DIR) images in ten volunteers. In numerical simulations, the CNR for SyFLAIR3 was increased in the T2WI and FLAIR images with long TEs, and the CSF ratio was decreased on those with short TEs. An in vivo study indicated that the CNR for SyFLAIR3 using T2WI and FLAIR images with an optimized combination of TEs was significantly higher than those for FLAIR and DIR images; whereas, the CSF ratio for the optimized SyFLAIR3 was not significantly different from that for the FLAIR images. The use of SyFLAIR3 improves the contrast within the region of the WM without the need for additional scanning in synthetic MRI.
引用
收藏
页码:118 / 125
页数:7
相关论文
共 50 条
  • [1] The use of combined T2-weighted and FLAIR synthetic magnetic resonance images to improve white matter region contrast: a feasibility study
    Fujiwara, Yasuhiro
    Inoue, Yumi
    Kanamoto, Masayuki
    Ishida, Shota
    Adachi, Toshiki
    Kimura, Hirohiko
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (01) : 118 - 125
  • [2] T2-weighted white matter hyperintensity on cerebral magnetic resonance imaging: A predictor of stroke
    Beauchamp, NJ
    Kuller, L
    Longstreth, WT
    Arnold, A
    Bernick, C
    Bryan, RN
    NEUROLOGY, 2002, 58 (07) : A98 - A99
  • [3] Quad-Contrast Imaging: Simultaneous Acquisition of Four Contrast-Weighted Images (PD-Weighted, T2-Weighted, PD-FLAIR and T2-FLAIR Images) With Synthetic T1-Weighted Image, T1- and T2-Maps
    Ji, Sooyeon
    Jeong, Jinhee
    Oh, Se-Hong
    Nam, Yoonho
    Choi, Seung Hong
    Shin, Hyeong-Geol
    Shin, Dongmyung
    Jung, Woojin
    Lee, Jongho
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (12) : 3617 - 3626
  • [4] Application of a multifractal analysis to study brain white matter abnormalities of schizophrenia on T2-weighted magnetic resonance imaging
    Takahashi, Tetsuya
    Kosaka, Hirotaka
    Murata, Tetsuhito
    Omori, Masao
    Narita, Kosuke
    Mitsuya, Hironori
    Takahashi, Koichi
    Kimura, Hirohiko
    Wada, Yuji
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2009, 171 (03) : 177 - 188
  • [5] T2-weighted white matter hyperintensity on cranial magnetic resonance imaging: A predictor of incident stroke
    Beauchamp, NJ
    Kuller, L
    Longstreth, WT
    Arnold, A
    Bernick, C
    Bryan, RN
    RADIOLOGY, 2001, 221 : 299 - 300
  • [6] Use of T1-weighted/T2-weighted magnetic resonance ratio images to elucidate changes in the schizophrenic brain
    Iwatani, Jun
    Ishida, Takuya
    Donishi, Tomohiro
    Ukai, Satoshi
    Shinosaki, Kazuhiro
    Terada, Masaki
    Kaneoke, Yoshiki
    BRAIN AND BEHAVIOR, 2015, 5 (10):
  • [7] Signal loss in the T2-weighted magnetic resonance images by using an USPIO-particle contrast agent
    Hong, Sungwook
    Rhee, Ilsu
    Chang, Yongmin
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (04) : 1453 - 1456
  • [8] Automatic Brain Tumor Detection in T2-weighted Magnetic Resonance Images
    Dvorak, P.
    Kropatsch, W. G.
    Bartusek, K.
    MEASUREMENT SCIENCE REVIEW, 2013, 13 (05): : 223 - 230
  • [9] Optimization of T2-weighted imaging for shoulder magnetic resonance arthrography by synthetic magnetic resonance imaging
    Lee, Seung Hyun
    Lee, Young Han
    Hahn, Seok
    Yang, Jaemoon
    Song, Ho-Taek
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2018, 59 (08) : 959 - 965
  • [10] An observational study of T2-weighted white matter hyperintensities on magnetic resonance imaging of the internal auditory meatus and brain: ignore or not?
    Huang, X.
    Grimmond, N.
    Kontorinis, G.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2021, 135 (11): : 964 - 969