Fluid flow and heat transfer characteristics for a square prism (blockage ratio = 0.1) placed inside a wind tunnel

被引:0
|
作者
Dipes Chakrabarty
Ranajit Brahma
机构
[1] MCKV Institute of Engineering,Department of Automobile Engineering
[2] Indian Institute of Technology,Department of Mechanical Engineering
来源
Heat and Mass Transfer | 2008年 / 44卷
关键词
Nusselt Number; Wind Tunnel; Drag Coefficient; Pressure Coefficient; Local Nusselt Number;
D O I
暂无
中图分类号
学科分类号
摘要
Experimental investigations in fluid flow and heat transfer have been carried out to study the effect of wall proximity due to flow separation around a square prism at Reynolds number 2.6 × 104, blockage ratio 0.1, different height-ratios and various angles of attack. The static pressure distribution has been measured on all faces of the square prism. The results have been presented in the form of pressure coefficient, drag coefficient for various height-ratios. The pressure distribution shows positive values on the front face whereas on the rear face negative values of the pressure coefficient have been observed. The positive pressure coefficient for different height-ratios does not vary too much but the negative values of pressure coefficient are higher for all points on the surface as the bluff body approaches towards the upper wall of the wind tunnel. The drag coefficient decreases with the increase in angle of attack as the height-ratio decreases. The maximum value of drag coefficient has been observed at an angle of attack nearly 50° for the square prism at all height-ratios. The heat transfer experiments have been carried out under constant heat flux condition. Heat transfer coefficient are determined from the measured wall temperature and ambient temperature and presented in the form of Nusselt number. Both local and average Nusselt numbers have been presented for various height-ratios. The variation of local Nusselt number has been shown with non-dimensional distance for different angles of attack. The variation of average Nusselt number has also been shown with different angles of attack. The local as well as average Nusselt number decreases as the height-ratio decreases for all non-dimensional distance and angle of attack, respectively, for the square prism. The average Nusselt number for the square prism varies with the angle of attack. But there is no definite angle of attack at which the value of average Nusselt number is either maximum or minimum.
引用
收藏
页码:325 / 330
页数:5
相关论文
共 50 条
  • [1] Fluid flow and heat transfer characteristics for a square prism (blockage ratio=0.1) placed inside a wind tunnel
    Chakrabarty, Dipes
    Brahma, Ranajit
    HEAT AND MASS TRANSFER, 2008, 44 (03) : 325 - 330
  • [2] Effect of wall proximity in fluid flow and heat transfer from a square prism placed inside a wind tunnel
    Chakrabarty, Dipes
    Brahma, Ranajit
    THERMAL SCIENCE, 2007, 11 (04): : 65 - 78
  • [3] Effect of wall proximity in fluid flow and heat transfer from a rectangular prism placed inside a wind tunnel
    Chakrabarty, Dipes
    Brahma, Ranajit Kumar
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (3-4) : 736 - 746
  • [4] Experimental study of fluid flow and heat transfer from a square prism approaching the wall of a wind tunnel
    Chakrabarty D.
    Brahma R.
    Journal of Engineering Physics and Thermophysics, 2009, 82 (4) : 697 - 705
  • [5] Investigating effects of sphere blockage ratio on the characteristics of flow and heat transfer in a sphere array
    Kao, M. T.
    Tung, Y. H.
    Ferng, Y. M.
    Chieng, C. C.
    ENERGY CONVERSION AND MANAGEMENT, 2014, 81 : 455 - 464
  • [6] EFFECTS OF BLOCKAGE RATIO AND PRANDTL NUMBER ON STEADY FLOW AND HEAT TRANSFER AROUND AN INCLINED SQUARE CYLINDER
    Aboueian-Jahromi, Jaber
    Nezhad, Alireza Hossein
    Behzadmehr, Amin
    HEAT TRANSFER RESEARCH, 2015, 46 (06) : 541 - 562
  • [7] Experimental study on fluid flow and heat transfer from a triangular prism approaching the wall of a wind tunnel (Reynolds number = 2.610 4)
    Department of Mechanical Engineering, Seacom Engineering College, JL-2: Jaladhulagori , Sankrail, Howrah, 711302, West Bengal, India
    不详
    Int. J. Heat Technol., 2008, 2 (35-44):
  • [8] Numerical investigation of heat transfer and fluid flow characteristics inside a wavy channel
    Xie, Gong-Nan
    Wang, Qiu-Wang
    Zeng, Min
    Luo, Lai-Qin
    HEAT AND MASS TRANSFER, 2007, 43 (07) : 603 - 611
  • [9] Numerical investigation of heat transfer and fluid flow characteristics inside a wavy channel
    Gong-Nan Xie
    Qiu-Wang Wang
    Min Zeng
    Lai-Qin Luo
    Heat and Mass Transfer, 2007, 43 : 603 - 611
  • [10] Numerical investigation of heat transfer and fluid flow characteristics inside a wavy channel
    Gong-Nan Xie
    Qiu-Wang Wang
    Min Zeng
    Lai-Qin Luo
    Heat and Mass Transfer, 2007, 43 (7) : 721 - 721