Impedance and electromyographic properties of metal dry bioelectrode with non-uniform surface microstructure

被引:0
|
作者
Wei Zhou
Yaoyao Li
Shaoyu Liu
Chenying Zhang
Haotian She
Jinying Zhu
机构
[1] Xiamen University,Department of Mechanical and Electrical Engineering
[2] Beijing Institute of Technology,School of Mechatronical Engineering
来源
Applied Physics A | 2018年 / 124卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
To develop a bioelectrode with excellent electrical performance, laser micromachining was proposed to fabricate a metal dry bioelectrode with a non-uniform surface microstructure. By controlling the scanning path, scanning times, and output power, metal dry bioelectrodes with different types of surface microstructure distribution (uniform and non-uniform) were obtained. Compared with traditional Ag/AgCl wet electrode, the influence of the surface microstructure distribution on the impedance and electromyographic properties of metal dry bioelectrodes was investigated. Results show that the surface microstructure distribution has little influence on the impedance properties of the bioelectrode within the testing time and frequency domains. However, the electromyographic properties of metal dry bioelectrodes with uniform and non-uniform surface microstructures were better than that of conventional Ag/AgCl wet electrodes. The strongest electromyographic signal was obtained using a metal dry bioelectrode with non-uniform surface microstructure.
引用
收藏
相关论文
共 50 条
  • [1] Impedance and electromyographic properties of metal dry bioelectrode with non-uniform surface microstructure
    Zhou, Wei
    Li, Yaoyao
    Liu, Shaoyu
    Zhang, Chenying
    She, Haotian
    Zhu, Jinying
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2018, 124 (11):
  • [2] Mechanical properties of surface microstructures of metal dry bioelectrode
    Zhou, Wei
    Liu, Shaoyu
    Li, Yaoyao
    Zhang, Chenying
    She, Haotian
    Zhu, Jinying
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 280 : 170 - 178
  • [3] Electrical impedance performance of metal dry bioelectrode with different surface coatings
    Liu, Wei
    Zhou, Wei
    Liu, Shaoyu
    Zhang, Chenying
    Huang, Shuaishuai
    Li, Yaoyao
    Hui, Kwan San
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 269 : 515 - 523
  • [4] Fabrication and impedance measurement of novel metal dry bioelectrode
    Zhou, Wei
    Song, Rong
    Pan, Xiaoling
    Peng, Youjian
    Qi, Xiaoyu
    Peng, Juehao
    Hui, K. S.
    Hui, K. N.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 201 : 127 - 133
  • [5] Characterization of impedance properties of metal dry bioelectrodes with surface microstructure arrays
    Zhou, Wei
    Liu, Wei
    Liu, Shaoyu
    Zhang, Chenying
    Shen, Zhijia
    Zhang, Guobiao
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 263 : 252 - 258
  • [6] THE CHARACTERISTIC IMPEDANCE OF A NON-UNIFORM WAVEGUIDE
    ZHENG, WX
    ZHANG, JT
    SHAO, HG
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1984, 56 (06) : 777 - 788
  • [7] Design of a Non-Uniform High Impedance Surface for a low profile antenna
    Hosseini, M.
    Pirhadi, A.
    Hakkak, M.
    PIERS 2006 CAMBRIDGE: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, PROCEEDINGS, 2006, : 352 - 356
  • [8] Non-uniform Surface Impedance Absorbing Boundary Condition for FDTD Method
    Mao, Yunlong
    Elsherbeni, Atef Z.
    Li, Si
    Jiang, Tao
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2018, 33 (02): : 232 - 235
  • [9] Design of a non-uniform high impedance surface for a low profile antenna
    Hosseini, M.
    Pirhadi, A.
    Hakkak, M.
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2006, 20 (11) : 1455 - 1464
  • [10] Non-uniform Surface Impedance Absorbing Boundary Condition for FDTD Method
    Mao, Yunlong
    Elsherbeni, Atef Z.
    Sili
    Jiang, Tao
    2017 11TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2017, : 516 - 519