Physical and biological pretreatment quality assurance of the head and neck cancer plan with the volumetric modulated arc therapy

被引:0
|
作者
So-Hyun Park
Dong-Soo Lee
Yun-Hee Lee
Seu-Ran Lee
Min-Ju Kim
Tae-Suk Suh
机构
[1] Uijeongbu St. Mary’s hospital,Department of Radiation Oncology
[2] Seoul St. Mary’s hospital,Department of Radiation Oncology
[3] The Catholic University of Korea College of Medicine,Department of Biomedical Engineering
来源
关键词
Quality assurance; Gamma passing rates; False negative; EUD; TCP/NTCP;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this work is to demonstrate both the physical and the biological quality assurance (QA) aspects as pretreatment QA of the head and neck (H&N) cancer plan for the volumetric modulated arc therapy (VMAT). Ten H&N plans were studied. The COMPASS® dosimetry analysis system and the tumor control probability (TCP) and the normal tissue complication probability (NTCP) calculation free program were used as the respective measurement and calculation tools. The reliability of these tools was verified by a benchmark study in accordance with the TG-166 report. For the physical component of QA, the gamma passing rates and the false negative cases between the calculated and the measured data were evaluated. The biological component of QA was performed based on the equivalent uniform dose (EUD), TCP and NTCP values. The evaluation was performed for the planning target volumes (PTVs) and the organs at risks (OARs), including the eyes, the lens, the parotid glands, the esophagus, the spinal cord, and the brainstem. All cases had gamma passing rates above 95% at an acceptance tolerance level with the 3%/3 mm criteria. In addition, the false negative instances were presented for the PTVs and OARs. The gamma passing rates exhibited a weak correlation with false negative cases. For the biological QA, the physical dose errors affect the EUD and the TCP for the PTVs, but no linear correlation existed between them. The EUD and NTCP for the OARs were shown the random differences that could not be attributed to the dose errors from the physical QA. The differences in the EUD and NTCP between the calculated and the measured results were mainly demonstrated for the parotid glands. This study describes the importance and the necessity of improved QA to accompany both the physical and the biological aspects for accurate radiation treatment.
引用
收藏
页码:946 / 955
页数:9
相关论文
共 50 条
  • [1] Physical and biological pretreatment quality assurance of the head and neck cancer plan with the volumetric modulated arc therapy
    Park, So-Hyun
    Lee, Dong-Soo
    Lee, Yun-Hee
    Lee, Seu-Ran
    Kim, Min-Ju
    Suh, Tae-Suk
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (05) : 946 - 955
  • [2] Volumetric Modulated Arc Therapy for Head & Neck Cancer
    Afghan, M. K. N.
    Cao, D.
    Mehta, V.
    Shepard, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2901 - +
  • [3] Single Arc Volumetric Modulated Arc Therapy of head and neck cancer
    Bertelsen, Anders
    Hansen, Christian R.
    Johansen, Jorgen
    Brink, Carsten
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 142 - 148
  • [4] Quality assurance of volumetric-modulated arc therapy head and neck cancer treatment using PRESAGE (R) dosimeter
    Rehman, Jalil Ur
    Isa, Muhammad
    Ahmad, Nisar
    Asghar, H. M. Noor ul Huda Khan
    Gilani, Zaheer A.
    Chow, James C. L.
    Afzal, Muhammad
    Ibbott, Geoffrey S.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (04) : 441 - 446
  • [5] Plan Robustness Study of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy for Head and Neck Cancer
    Liu, W.
    Patel, S. H.
    Shen, J.
    Stoker, J.
    Ding, X.
    Hu, Y.
    Wong, W. W.
    Halyard, M. Y.
    Ezzell, G. A.
    Schild, S. E.
    Bues, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E567 - E568
  • [6] Correlation Study of Volumetric Modulated Arc Therapy Plan Robustness With Local Failure for Head and Neck Cancer
    Liu, W.
    Patel, S. H.
    Harrington, D.
    Stoker, J.
    Ding, X.
    Shen, J.
    Wong, W. W.
    Halyard, M. Y.
    Schild, S. E.
    Ezzell, G. A.
    Bues, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E309 - E310
  • [7] Volumetric Modulated Arc Therapy Optimization Strategy for a Head and Neck Cancer
    Singh, N.
    Ahamed, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E290 - E290
  • [8] Improvement Using Planomics Features on Prediction and Classification of Patient-Specific Quality Assurance Using Head and Neck Volumetric Modulated Arc Therapy Plan
    Li, Bing
    Chen, Junying
    Guo, Wei
    Mao, Ronghu
    Zheng, Xiaoli
    Cheng, Xiuyan
    Cui, Tiantian
    Lou, Zhaoyang
    Wang, Ting
    Li, Dingjie
    Tao, Hongyan
    Lei, Hongchang
    Ge, Hong
    [J]. FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [9] Adaptive Radiotherapy in Head and Neck Cancer Using Volumetric Modulated Arc Therapy
    Buciuman, Nikolett
    Marcu, Loredana G.
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (05):
  • [10] Multileaf Collimator Quality Assurance for Volumetric Modulated Arc Therapy
    Lin, T.
    Hossain, M.
    Ma, C.