Early diastolic strain rate predicts response to heart failure therapy in patients with dilated cardiomyopathy

被引:0
|
作者
Björn Goebel
Kristina H. Haugaa
Kathleen Meyer
Sylvia Otto
Christian Jung
Alexander Lauten
Hans R. Figulla
Thor Edvardsen
Tudor C. Poerner
机构
[1] University Hospital of Jena,1st Department of Medicine, Division of Cardiology
[2] Rikshospitalet University Hospital,Department of Cardiology
[3] University of Oslo,undefined
关键词
Dilated cardiomyopathy; Speckle tracking echocardiography; Heart failure therapy;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this prospective study was to assess the value of speckle tracking echocardiographic (2D-STE) parameters to predict response to heart failure therapy in patients with dilated cardiomyopathy (DCM). Eighty-seven patients (mean age 51 ± 13 years) with DCM, defined as ejection fraction (EF) <45 %, left ventricular (LV) end-diastolic diameter >112 % of normal range derived from age and body surface area. Based on 2D-STE following parameters were extracted from three apical views of the LV: global longitudinal strain, systolic and diastolic strain rate (SRE). Mechanical dispersion was calculated as standard deviation of time-to-peak strain values including all LV segments. After receiving heart failure therapy (mean 39 ± 11 months, range 3–60 months) 50 patients reached combined endpoint defined as following: death, heart transplantation, rehospitalization due to heart failure, and absence of improvement in EF. On stepwise multivariate regression analysis, SRE was independently of EF and LV volumes predictive for combined endpoint (OR 0.44, 95 %CI 0.27–0.70, p = 0.001) with an area under the ROC-curve (AUC) of 0.91. In patients with cQRS duration ≤120 ms mechanical dispersion was predictive for combined endpoint with the highest AUC (OR 1.53, 95 %CI 1.08–2.16, p = 0.002; AUC = 0.94). In this study, SRE, a surrogate parameter of myocardial relaxation, was able to predict a response to heart failure therapy in patients with DCM. In patients with narrow QRS complex, mechanical dispersion yielded the highest predictive value. Parameters of 2D-STE may contribute to risk stratification in this patient population.
引用
收藏
页码:505 / 513
页数:8
相关论文
共 50 条
  • [1] Early diastolic strain rate predicts response to heart failure therapy in patients with dilated cardiomyopathy
    Goebel, B.
    Haugaa, K.
    Meyer, K.
    Otto, S.
    Jung, C.
    Mall, G.
    Figulla, H. R.
    Poerner, T. C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 477 - 477
  • [2] Early diastolic strain rate predicts response to heart failure therapy in patients with dilated cardiomyopathy
    Goebel, Bjorn
    Haugaa, Kristina H.
    Meyer, Kathleen
    Otto, Sylvia
    Jung, Christian
    Lauten, Alexander
    Figulla, Hans R.
    Edvardsen, Thor
    Poerner, Tudor C.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (03): : 505 - 513
  • [3] Early Diastolic Strain Rate Predicts Response to Heart Failure Therapy in Patients With Dilated Cardiomyopathy
    Goebel, Bjoern
    Haugaa, Kristina
    Meyer, Kathleen
    Otto, Sylvia
    Jung, Christian
    Mall, Gerhard
    Figulla, Hans R.
    Edvardsen, Thor
    Poerner, Tudor C.
    CIRCULATION, 2012, 126 (21)
  • [4] Ratio of transmitral early filling velocity to early diastolic strain rate predicts outcomes in patients with systolic heart failure
    Chan, Yi-Hsin
    Lee, Hsin-Fu
    Wu, Lung-Sheng
    Wang, Chun-Li
    Wu, Chia-Tung
    Yeh, Yung-Hsin
    Ho, Y. Wan-Jing
    Hsu, Lung-An
    Chu, Pao-Hsien
    Kuo, Chi-Tai
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (01) : 79 - 85
  • [5] Left ventricular systolic and diastolic dyssynchrony to improve cardiac resynchronization therapy response in heart failure patients with dilated cardiomyopathy
    Cheng Wang
    Jianzhou Shi
    Jiacheng Ge
    Haipeng Tang
    Zhuo He
    Yanyun Liu
    Zhongqiang Zhao
    Chunxiang Li
    Kai Gu
    Xiaofeng Hou
    Minglong Chen
    Jiangang Zou
    Lei Zhou
    Ernest V. Garcia
    Dianfu Li
    Weihua Zhou
    Journal of Nuclear Cardiology, 2021, 28 : 1023 - 1036
  • [6] Left ventricular systolic and diastolic dyssynchrony to improve cardiac resynchronization therapy response in heart failure patients with dilated cardiomyopathy
    Wang, Cheng
    Shi, Jianzhou
    Ge, Jiacheng
    Tang, Haipeng
    He, Zhuo
    Liu, Yanyun
    Zhao, Zhongqiang
    Li, Chunxiang
    Gu, Kai
    Hou, Xiaofeng
    Chen, Minglong
    Zou, Jiangang
    Zhou, Lei
    Garcia, Ernest, V
    Li, Dianfu
    Zhou, Weihua
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (03) : 1023 - 1036
  • [7] Immunoadsorption Therapy for Patients with Dilated Cardiomyopathy and Heart Failure
    Ikeda, Uichi
    Kasai, Hiroki
    Izawa, Atsushi
    Koyama, Jun
    Yazaki, Yoshikazu
    Takahashi, Masafumi
    Higuchi, Makoto
    Koh, Chang-Sung
    Yamamoto, Keiji
    CURRENT CARDIOLOGY REVIEWS, 2008, 4 (03) : 219 - 222
  • [8] Electrocardiographic Predictors of Response to Cardiac Resynchronization Therapy of Heart Failure in Patients With Dilated Cardiomyopathy
    Vaikhanskaya, T. G.
    Kurushko, T. V.
    Sidorenko, I. V.
    Kaptsiukh, T. M.
    Gul, L. M.
    Melnikova, O. P.
    Golenischa, V. F.
    Kovalenko, O. N.
    KARDIOLOGIYA, 2013, 53 (03) : 48 - 54
  • [9] Predictors of heart failure in patients with early and preclinical dilated cardiomyopathy
    Vaikhanskaya, T. Tatiyana
    Kurushka, T. V.
    Sivitskaya, L. N.
    Danilenko, N. G.
    Liaudanski, A. D.
    Davydenko, O. G.
    EUROPEAN JOURNAL OF HEART FAILURE, 2020, 22 : 126 - 126
  • [10] End-Diastolic Volume Predicts Response to Cell Therapy in Patients With Non-Ischemic Dilated Cardiomyopathy
    Frljak, Sabina
    Jaklic, Martina
    Poglajen, Gregor
    Zemljic, Gregor
    Cerar, Andraz
    Haddad, Francois
    Terzic, Andre
    Vrtovec, Bojan
    CIRCULATION, 2018, 138