Measuring Humidity in Methane and Natural Gas with a Microwave Technique

被引:1
|
作者
R. M. Gavioso
D. Madonna Ripa
R. Benyon
J. G. Gallegos
F. Perez-Sanz
S. Corbellini
S. Avila
A. M. Benito
机构
[1] Istituto Nazionale di Ricerca Metrologica,Thermodynamics Division
[2] Instituto Nacional de Técnica Aerospacial,undefined
[3] Universidad de Valladolid,undefined
[4] Politecnico di Torino,undefined
[5] ENAGAS,undefined
[6] SA,undefined
来源
关键词
Microwave hygrometry; Natural gas; Microwave resonator;
D O I
暂无
中图分类号
学科分类号
摘要
The results of microwave measurements with a quasi-spherical resonator in humid methane samples realized under laboratory conditions at the Istituto Nazionale di Ricerca Metrologica (INRiM) and under industrial conditions in a natural gas sample made available at the facilities of the Technical Manager of the Spanish Gas System and main supplier of natural gas in Spain (ENAGAS) are reported. Measurements at INRiM included vapor phase and condensation tests on methane samples prepared with amount fractions of water between 600 ppm and 5000 ppm at temperatures between 273 K and 295 K and pressures between 150 kPa and 1 MPa. ENAGAS measurements were performed at ambient temperature, 750 kPa on natural gas sampled from the pipeline and successively humidified at amount fractions of water between 140 ppm and 250 ppm for completeness of the comparison with several humidity sensors and instrumentation based on different technologies. To enhance the sensitivity of the microwave method at low humidity, an experimental procedure based on the relative comparison of the dielectric permittivity of the humid gas sample before and after being subject to a chemical drying process was conceived and implemented. The uncertainty budget and the final sensitivity of this procedure are discussed.
引用
收藏
页码:748 / 766
页数:18
相关论文
共 50 条
  • [1] Measuring Humidity in Methane and Natural Gas with a Microwave Technique
    Gavioso, R. M.
    Ripa, D. Madonna
    Benyon, R.
    Gallegos, J. G.
    Perez-Sanz, F.
    Corbellini, S.
    Avila, S.
    Benito, A. M.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (3-4) : 748 - 766
  • [2] DEVICE FOR MEASURING GAS HUMIDITY
    SUVORKIN, VS
    [J]. MEASUREMENT TECHNIQUES, 1975, 18 (08) : 1256 - 1257
  • [3] MEASURING THE GAS HUMIDITY BY A DIELECTRIC METHOD
    POTAPOV, AA
    [J]. MEASUREMENT TECHNIQUES USSR, 1985, 28 (06): : 548 - 551
  • [4] Humidity determination of hydrated media by a microwave technique
    Peuch, JC
    Ani, N
    da Mata, W
    Baudrand, H
    [J]. 1997 SBMO/IEEE MTTS-S - INTERNATIONAL MICROWAVE AND OPTOELECTRONICS CONFERENCE, PROCEEDINGS, VOLS 1 AND 2, 1997, : 23 - 27
  • [5] ON-LINE MICROWAVE SYSTEM FOR HUMIDITY MEASURING WITH MICROPROCESSOR
    火真棣
    伏寿春
    [J]. Journal of Electronics(China), 1987, (03) : 225 - 233
  • [6] The application of neural network in the microwave method for measuring the humidity
    Jing, Junfeng
    Sun, Le
    Li, Pengfei
    Su, Zebin
    [J]. Advances in Information Sciences and Service Sciences, 2012, 4 (20): : 139 - 145
  • [7] Measuring methane emissions during the installation of residential and commercial natural gas meters in China
    Xu, Xiangang
    Zhong, Xinyue
    Dong, Jiankai
    Xie, Donglai
    Lu, Wanlu
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 904
  • [8] Methane and Natural Gas Utilization
    Li, Yongdan
    Veser, Gotz
    [J]. ENERGY TECHNOLOGY, 2020, 8 (08)
  • [9] The impact of oxidiser humidity on methane combustion in a gas burner
    Avramenko, Andrii N.
    [J]. FRENCH-UKRAINIAN JOURNAL OF CHEMISTRY, 2020, 8 (02): : 48 - 59
  • [10] Methane Gas Hydrate: as a Natural Gas Source
    Demirbas, Ayhan
    [J]. Green Energy and Technology, 2010, 34 : 113 - 160