Biodegradation of absorbable hydroxyapatite/poly-DL-lactide composites in different environment

被引:0
|
作者
Qi-xin Z. [1 ]
Xiao-dong G. [1 ]
Jing-yuan D. [1 ]
Yong-chao W. [1 ]
Da-ping Q. [2 ]
Yu-hua Y. [2 ]
Shi-pu L. [2 ]
机构
[1] Dept. of Orthopaedics, Union Hospital, Tongii Medical College, Huazhong University of Science and Technology
[2] Wuhan University of Technology, Wuhan
关键词
Absorbable material; Biodegradation; Hydroxyapatite; Osteosynthetic materials; Poly-DL-lactide;
D O I
10.1007/BF02838533
中图分类号
学科分类号
摘要
To develop a new generation of absorbable fracture fixation devices with enhanced biocompatibility, the biodegradation mechanism and its influence on the cellular response at the tissue/implant interface of hydroxyapatite/poly-DL-lactide (HA/PDLLA) composites were investigated in vitro and in vivo. HA/PDLLA rods were immersed in phosphate-buffered saline, or implanted in muscle and bony tissue for 52 weeks. Scanning electron microscopic and histological studies were done. The degradation rate was the slowest in vitro, slower in muscle tissue and fast in bone. In vitro, the composites degraded heterogeneously and a hollow structure was formed. In bone, the limited clearing capacity leads to the accumulation of oligomeric debris, which contribute totally to the autocatalytic effect. So, the fastest degradation and intense tissue response were seen. In muscle tissue, oligomeric debris migrated into vicinal fibers over a long distance from the original implant cavity and the tissue reactions were, however, quite moderate. For the same size organic/inorganic composite, the environment where it was placed is the major factor in determining its biodegradation process and cellular reaction. In living tissue, factors such as cells, enzymes and mechanical stress have an obvious influence on the biodegradation and biological process at the tissue/implant interface. The biocompatibility of the HA/PDLLA composites is enhanced with the incorporating of the resorbable HA microparticles.
引用
收藏
页码:24 / 29
页数:5
相关论文
共 50 条
  • [2] Biodegradation of absorbable hydroxyapatite/poly-DL-lactide composites in different environment
    Zheng, Qi-Xin
    Guo, Xiao-Dong
    Du, Jing-Yuan
    Wu, Yong-Chao
    Quan, Da-Ping
    Yan, Yu-Hua
    Li, Shi-Pu
    Journal Wuhan University of Technology, Materials Science Edition, 2002, 17 (03): : 24 - 29
  • [3] Biodegradation of absorbable hydroxyapatite/poly-DL-lactide composites in different environment
    Zheng, QX
    Guo, XD
    Du, JY
    Wu, YC
    Quan, DP
    Yan, YH
    Li, SP
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2002, 17 (03): : 24 - 29
  • [5] Biodegradation and mechanical properties of hydroxyapatite/poly-DL-lactide composites for fracture fixation
    Guo, XD
    Zheng, QX
    Du, JY
    Quan, DP
    Yan, YH
    Li, SP
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 1998, 13 (04): : 9 - 15
  • [6] Biodegradation and mechanical properties of hydroxyapatite/poly-DL-lactide composites for fracture fixation
    Guo, Xiaodong
    Zheng, Qixin
    Du, Jingyuan
    Quan, Dapin
    Yan, Yuhua
    Li, Shipu
    Journal Wuhan University of Technology, Materials Science Edition, 1998, 13 (04): : 9 - 15
  • [7] Effect of Absorbable Hydroxyapatite/Poly-DL-Lactide Rods on Experimental Fracture Healing
    郭晓东
    郑启新
    杜靖远
    刘勇
    Journal of Tongji Medical University, 2000, (01) : 72 - 76
  • [8] Effect of absorbable hydroxyapatite/poly-DL-lactide rods on experimental fracture healing
    Guo Xiaodong
    Zheng Qixin
    Du Jingyuan
    Liu Yong
    Current Medical Science, 2000, 20 (1) : 72 - 76
  • [9] Effect of absorbable hydroxyapatite/poly-DL-lactide rods on experimental fracture healing
    Guo, Xiaodong
    Zheng, Qixin
    Du, Jingyuan
    Liu, Yong
    Journal of Tongji Medical University, 2000, 20 (01) : 72 - 76
  • [10] Study of biodegradation of hydroxyapatite/poly(DL-lactide) composites at different sites
    Guo, X.D.
    Zheng, Q.X.
    Du, J.Y.
    Quan, D.P.
    Zhongguo Shengwu Yixue Gongcheng Xuebao/Chinese Journal of Biomedical Engineering, 2001, 20 (03):