Determination of electrokinetic charge with a particle-charge detector, and its relationship to the total charge

被引:0
|
作者
Böckenhoff K. [1 ]
Fischer W.R. [1 ]
机构
[1] Institut für Bodenkunde, Universität Hannover, 30419 Hannover
来源
关键词
Total Charge; Latex Particle; Stern Layer; Streaming Potential; Latex Sample;
D O I
10.1007/s002160100897
中图分类号
学科分类号
摘要
The main features of polyelectrolyte titrations with end-point indication by means of a particle-charge detector (PCD) were investigated. Because of their well-defined character, the charges of different synthetic polyelectrolytes and of latex samples with different functional groups were measured at different pH and ionic strength. The results show that PCD is a valuable tool for detecting effective or dissociated counterion charge without additional model assumptions. For negatively charged samples with exclusively strong acid functional groups, an excellent agreement was obtained between cation-exchange capacity and the charge measured by PCD over a wide pH range. For samples with additional carboxyl groups, the PCD charge was significantly lower than the total charge calculated from cation-exchange results. It can be concluded that counterion immobilization by a Stern layer-type arrangement is responsible for this effect.
引用
收藏
页码:670 / 674
页数:4
相关论文
共 50 条
  • [1] Determination of electrokinetic charge with a particle-charge detector, and its relationship to the total charge
    Böckenhoff, K
    Fischer, WR
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (05): : 670 - 674
  • [2] PARTICLE-CHARGE MAGNITUDES IN ELECTROSTATIC PRECIPITATION
    HIGNETT, ET
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1967, 114 (09): : 1325 - &
  • [3] Direct determination of the charge of the beta particle
    Ladenburg, R
    Beers, Y
    PHYSICAL REVIEW, 1940, 58 (08): : 757 - 757
  • [4] Effects of induced charge in the kinestatic charge detector
    Department of Radiology, Harvard Medical School, Brigham and Women's Hospital, Boston, MA 02115, United States
    MED. PHYS., 5 (627-634):
  • [5] EFFECTS OF INDUCED CHARGE IN THE KINESTATIC CHARGE DETECTOR
    WAGENAAR, DJ
    TERWILLIGER, RA
    MEDICAL PHYSICS, 1995, 22 (05) : 627 - 634
  • [6] CLOSE-PACKED DETECTOR TO MEASURE PARTICLE CHARGE
    PODOROZNHYI, DM
    KHEIN, LA
    SHESTOPEROV, VY
    YASHIN, IV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1994, 37 (01) : 27 - 30
  • [7] Close-packed detector determining a particle charge
    Podorozhnyj, D.M.
    Khejn, L.A.
    Shestoperov, V.Ya.
    Yashin, I.V.
    Pribory i Tekhnika Eksperimenta, 1994, (01): : 49 - 53
  • [8] SPACE-CHARGE EFFECTS IN A KINESTATIC CHARGE DETECTOR
    WAGENAAR, DJ
    DIBIANCA, FA
    TENNEY, CR
    FRITSCH, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (01): : 61 - 76
  • [9] ELECTROACOUSTIC DETERMINATION OF PARTICLE-SIZE AND CHARGE
    OBRIEN, RW
    CANNON, DW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 201 - COLL
  • [10] Direct determination of the charge of the beta-particle
    Beers, Y
    PHYSICAL REVIEW, 1943, 63 (3/4): : 0077 - 0085