MCO Membranes: Enhanced Selectivity in High-Flux Class

被引:0
|
作者
Adriana Boschetti-de-Fierro
Manuel Voigt
Markus Storr
Bernd Krause
机构
[1] Gambro Dialysatoren GmbH,Research & Development
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Novel MCO high-flux membranes for hemodialysis have been developed with optimized permeability, allowing for filtration close to that of the natural kidney. A comprehensive in vitro characterization of the membrane properties by dextran filtration is presented. The sieving profile of pristine membranes, as well as that of membranes exposed to blood for 40 minutes, are described. The effective pore size (Stokes-Einstein radius) was estimated from filtration experiments before and after blood exposure and results were compared to hydrodynamic radii of middle and large uremic toxins and essential proteins. The results indicate that the tailored pore sizes of the MCO membranes promote removal of large toxins while ensuring the retention of albumin.
引用
收藏
相关论文
共 50 条
  • [1] MCO Membranes: Enhanced Selectivity in High-Flux Class
    Boschetti-de-Fierro, Adriana
    Voigt, Manuel
    Storr, Markus
    Krause, Bernd
    [J]. SCIENTIFIC REPORTS, 2015, 5
  • [2] MCO® MEMBRANES: ENHANCED SELECTIVITY IN HIGH-FLUX CLASS
    Boschetti-de-Fierro, Adriana
    Voigt, Manuel
    Storr, Markus
    Krause, Bernd
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [4] High-selectivity, high-flux silica membranes for gas separation
    de Vos, RM
    Verweij, H
    [J]. SCIENCE, 1998, 279 (5357) : 1710 - 1711
  • [5] BIOCOMPATIBILITY OF HIGH-FLUX MEMBRANES
    PUTZ, D
    BARNAS, U
    LUGER, A
    MAYER, G
    WOLOSZCZUK, W
    GRAF, H
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (08): : 456 - 460
  • [6] High-flux MFI membranes
    Hedlund, J
    Sterte, J
    Anthonis, M
    Bons, AJ
    Carstensen, B
    Corcoran, N
    Cox, D
    Deckman, H
    De Gijnst, W
    de Moor, PP
    Lai, F
    McHenry, J
    Mortier, W
    Reinoso, J
    [J]. MICROPOROUS AND MESOPOROUS MATERIALS, 2002, 52 (03) : 179 - 189
  • [7] All high-flux membranes are equal but some high-flux membranes are less equal than others
    Vanholder, Raymond
    Pedrini, Luciano A.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2008, 23 (05) : 1481 - 1483
  • [8] High-Flux and Low-Flux Membranes in Hemodialysis
    Oshvandi, Khodayar
    Kavyannejad, Rasol
    Borzuo, Sayed Reza
    Gholyaf, Mahmoud
    [J]. NURSING AND MIDWIFERY STUDIES, 2014, 3 (03)
  • [9] β-trace protein is highly removed during haemodialysis with high-flux and super high-flux membranes
    Donadio, Carlo
    Tognotti, Danika
    Caponi, Laura
    Paolicchi, Aldo
    [J]. BMC NEPHROLOGY, 2017, 18
  • [10] β-trace protein is highly removed during haemodialysis with high-flux and super high-flux membranes
    Carlo Donadio
    Danika Tognotti
    Laura Caponi
    Aldo Paolicchi
    [J]. BMC Nephrology, 18