Mitigating the seismic pounding of multi-story buildings in series using linear and nonlinear fluid viscous dampers

被引:20
|
作者
Elwardany, Hytham [1 ]
Jankowski, Robert [2 ]
Seleemah, Ayman [3 ]
机构
[1] Delta Univ Sci & Technol, Fac Engn, Struct Engn Dept, Belkas, Egypt
[2] Gdansk Univ Technol, Fac Civil & Environm Engn, Gdansk, Poland
[3] Tanta Univ, Fac Engn, Struct Engn Dept, Tanta, Egypt
关键词
Series of structures; Structural pounding; Linear fluid viscous dampers; Nonlinear fluid viscous dampers; Earthquakes; Contact surfaces; ADJACENT BUILDINGS; DYNAMICS; BEHAVIOR; DAMAGE; MODEL; SLIP;
D O I
10.1007/s43452-021-00249-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic-induced pounding between adjacent buildings may have serious consequences, ranging from minor damage up to total collapse. Therefore, researchers try to mitigate the pounding problem using different methods, such as coupling the adjacent buildings with stiff beams, connecting them using viscoelastic links, and installing damping devices in each building individually. In the current paper, the effect of using linear and nonlinear fluid viscous dampers to mitigate the mutual pounding between a series of structures is investigated. Nonlinear finite-element analysis of a series of adjacent steel buildings equipped with damping devices was conducted. Contact surfaces with both contactor and target were used to model the mutual pounding. The results indicate that the use of linear or nonlinear dampers leads to the significant reduction in the response of adjacent buildings in series. Moreover, the substantial improvement of the performance of buildings has been observed for almost all stories. From the design point of view, it is concluded that dampers implemented in adjacent buildings should be designed to resist maximum force of 6.20 or 1.90 times the design independent force in the case of using linear or nonlinear fluid viscous dampers, respectively. Also, designers should pay attention to the design of the structural elements surrounding dampers, because considerable forces due to pounding may occur in the dampers at the maximum displaced position of the structure.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Seismic poundings of multi-story buildings isolated by TFPB against moat walls
    Shakouri, Ayoub
    Amiri, Gholamreza Ghodrati
    Miri, Zahra Sadat
    Lak, Hamed Rajaei
    EARTHQUAKES AND STRUCTURES, 2021, 20 (03) : 295 - 307
  • [42] Optimum seismic design of multi-story buildings for increasing collapse resistant capacity
    Li, Shuang
    Yu, Bin
    Gao, Mengmeng
    Zhai, Changhai
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 116 : 495 - 510
  • [43] Seismic Vulnerability Assessment of Existing Multi-Story Reinforced Concrete Buildings in Egypt
    El-Kholy, Said A.
    El-Assaly, Mohamed S.
    Maher, Medhat
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (02): : 341 - 355
  • [44] Effectiveness of non-linear fluid viscous dampers in seismically isolated buildings
    Guler, Elif
    Alhan, Cenk
    EARTHQUAKES AND STRUCTURES, 2019, 17 (02) : 191 - 204
  • [45] The effectiveness of viscous-damping walls for controlling wind vibrations in multi-story buildings
    Yeung, N
    Pan, ADE
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1998, 77-8 : 337 - 348
  • [46] Seismic Upgrade of Existing Buildings with Fluid Viscous Dampers: Design Methodologies and Case Study
    Guo, Tong
    Xu, Jia
    Xu, Weijie
    Di, Zhiqiang
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2015, 29 (06)
  • [47] Study of Nonlinear Fluid Viscous Dampers Behaviour in Seismic Steel Structures Design
    Ras, Abdelouahab
    Boumechra, Nadir
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (12) : 8635 - 8648
  • [48] Study of Nonlinear Fluid Viscous Dampers Behaviour in Seismic Steel Structures Design
    Abdelouahab Ras
    Nadir Boumechra
    Arabian Journal for Science and Engineering, 2014, 39 : 8635 - 8648
  • [49] Probabilistic seismic response assessment of linear systems equipped with nonlinear viscous dampers
    Tubaldi, Enrico
    Ragni, Laura
    Dall'Asta, Andrea
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (01): : 101 - 120
  • [50] Modal response characteristics of a seismic control multi-Story shear building using a tuned viscous mass damper
    Ikago, K.
    Sugimura, Y.
    Saito, K.
    Inoue, N.
    Civil-Comp Proceedings, 2013, 102