A new amperometric biosensor for fructose determination based on epoxy-graphite-TTF-TCNQ-FDH-biocomposite

被引:0
|
作者
José Luis Montañez-Soto
Salvador Alegret
Juan Alfredo Salazar-Montoya
Emma Gloria Ramos-Ramírez
机构
[1] CINVESTAV-IPN,Department of Biotechnology and Bioengineering
[2] GSB,Department of Chemistry
[3] UAB,undefined
来源
关键词
Biosensor; Fructose determination; Fructose dehydrogenase (FDH); Tetrathiofulvalene (TTF); Tetracyanoquinodimethane (TCNQ);
D O I
暂无
中图分类号
学科分类号
摘要
In this work a novel amperometric biosensor for fructose determination in solutions was developed. The device was constructed by the incorporation of a tetrathiofulvalene-tetracyanoquinodimethane organic conducting salt and fructose dehydrogenase enzyme, include in a polymeric matrix of epoxy resin and graphite powder. Because of the electrocatalytic function of the salt, the direct transfer of the electron between the reduced prosthetic group (PQQH2) of the enzyme and the transducing material, was verified at a low working potential (150 mV vs. Ag/AgCl), where the interfering reactions were minimized. The response time at 90% of the steady state value was less than 20 s. The current response was directly proportional to the D-fructose concentration from 0.01 to 0.3 mmol/l with a detection limit of 0.005 mmol/l (signal/noise of 3) and a sensitivity of 1.9985 μA/mmol. The biosensor sensitivity diminishes when its surface is not polished between successive determinations, and remains constant (rsd=1.85, n=10) when the surface is polished between determinations. The effects of temperature and pH on the biosensor response were studied and analyzed; also the properties of the enzyme (Kmap, Imax, Q10) were determinate in this work. The biosensor was used to determine fructose in high fructose syrups and there were not significant differences between these results and those obtained by HPLC (p≤0.05). During 4 months, in intermittent determinations the biosensor kept 100% of its original sensitivity and after 18 months stored at 4°C, it only lost 32% of its sensitivity. The simplicity, low working potential, high stability and good performance of this biosensor shows a great potential for its use in the fructose determination.
引用
收藏
页码:379 / 386
页数:7
相关论文
共 28 条
  • [1] A new amperometric biosensor for fructose determination based on epoxy-graphite-TTF-TCNQ-FDH-biocomposite
    Montanez-Soto, Jose Luis
    Alegret, Salvador
    Salazar-Montoya, Juan Alfredo
    Ramos-Ramirez, Emma Gloria
    [J]. EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2006, 223 (03) : 379 - 386
  • [2] AMPEROMETRIC DETERMINATION OF PESTICIDES USING A BIOSENSOR BASED ON A POLISHABLE GRAPHITE-EPOXY BIOCOMPOSITE
    MARTORELL, D
    CESPEDES, F
    MARTINEZFABREGAS, E
    ALEGRET, S
    [J]. ANALYTICA CHIMICA ACTA, 1994, 290 (03) : 343 - 348
  • [3] Integration of a glucose biosensor based on an epoxy-graphite-TTF•TCNQ-GOD biocomposite into a FIA system
    Llopis, X
    Merkoçi, A
    del Valle, M
    Alegret, S
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (02) : 742 - 748
  • [4] AMPEROMETRIC BIOSENSOR FOR PHENOLS BASED ON A TYROSINASE GRAPHITE-EPOXY BIOCOMPOSITE
    WANG, J
    FANG, L
    LOPEZ, D
    [J]. ANALYST, 1994, 119 (03) : 455 - 458
  • [5] Hydrogen peroxide amperometric biosensor based on a peroxidase-graphite-epoxy biocomposite
    Morales, A
    Cespedes, F
    Munoz, J
    MartinezFabrega, E
    Alegret, S
    [J]. ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) : 131 - 138
  • [6] AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON A TETRATHIAFULVALENE-MEDIATED EPOXY-GRAPHITE BIOCOMPOSITE
    CESPEDES, F
    MARTINEZFABREGAS, E
    ALEGRET, S
    [J]. ELECTROANALYSIS, 1994, 6 (09) : 759 - 763
  • [7] A new, third generation, PVC/TTF-TCNQ composite amperometric biosensor for glucose determination
    Cano, Manuel
    Avila, J. Luis
    Mayen, Manuel
    Mena, M. L.
    Pingarron, J.
    Rodriguez-Amaro, Rafael
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 615 (01) : 69 - 74
  • [8] AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON AN ELECTROCATALYTICALLY BULK-MODIFIED EPOXY-GRAPHITE BIOCOMPOSITE
    CESPEDES, F
    MARTINEZFABREGAS, E
    ALEGRET, S
    [J]. ANALYTICA CHIMICA ACTA, 1993, 284 (01) : 21 - 26
  • [9] Ethanol amperometric biosensor based on an alcohol oxidase graphite-polymer biocomposite
    Morales, A
    Cespedes, F
    Martinez-Fabregas, E
    Alegret, S
    [J]. ELECTROCHIMICA ACTA, 1998, 43 (23) : 3575 - 3579
  • [10] A gold nanoparticle-modified PVC/TTF-TCNQ composite amperometric biosensor for glucose determination
    Sanchez-Obrero, Guadalupe
    Cano, Manuel
    Luis Avila, Jose
    Mayen, Manuel
    Luz Mena, Mari
    Manuel Pingarron, Jose
    Rodriguez-Amaro, Rafael
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 634 (01) : 59 - 63