Venous incompetence in erectile dysfunction: evaluation with color-coded duplex sonography and cavernosometry/-graphy

被引:0
|
作者
G. Fürst
V. Müller-Mattheis
M. Cohnen
C. Trautner
B. Haastert
A. Saleh
J. Malms
R. Ackermann
U. Mödder
机构
[1] Institute of Diagnostic Radiology,
[2] Heinrich Heine University,undefined
[3] P. O. Box 101007,undefined
[4] D-40001 Düsseldorf,undefined
[5] Germany,undefined
[6] Department of Urology,undefined
[7] Heinrich Heine University,undefined
[8] P. O. Box 101007,undefined
[9] D-40001 Düsseldorf,undefined
[10] Germany,undefined
[11] Institute for Social Medicine and Epidemiology,undefined
[12] Charité University Hospital,undefined
[13] D-10098 Berlin,undefined
[14] Germany,undefined
[15] Department of Biometrics and Epidemiology,undefined
[16] Diabetes Research Institute at Heinrich Heine University,undefined
[17] D-40225 Düsseldorf,undefined
[18] Germany,undefined
来源
European Radiology | 1999年 / 9卷
关键词
Key words: Penile erection; Impotence; Sonography; Doppler studies; Veno-occlusive dysfunction (venous insufficiency);
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to assess the accuracy of multi-parameter measurements with color-coded duplex sonography (CCDS) for the diagnosis of venous leakage in patients with erectile dysfunction. Sixty patients with repeated unsatisfactory reactions after intracavernous injection of vasoactive substances underwent CCDS. Following intracavernous injection of prostaglandin E1, peak systolic velocity (PSV), enddiastolic velocity (EDV), time averaged velocity (TAV), resistance index (RI), and pulsatility index (PI) were measured in the cavernous arteries over 30 min (one measurement per minute). The results were compared with independent measurements based on dynamic pharmaco-cavernosometry/cavernosography (DPCC). Dynamic pharmaco-cavernosometry/cavernosography revealed venous leakage in 33 patients. Of 48 patients with normal PSV ( > 25 cm/s), 25 had veno-occlusive dysfunction and the remainder presented normal venous function. No statistically significant differences between these groups were found in EDV, RI, and PI measurements. In contrast, differences in TAV were significant between patients with (mean 9.4 ± 4.6 cm/s) and without venous leakage (mean 5.5 ± 2.2 cm/s; p = 0.001). Analysis of relative frequencies revealed a broad overlap of EDV, TAV, RI, and PI measurements between both groups. Sensitivities and specificities determined from receiver-operating-characteristic curves were > 80 % and > 50 % for a TAV threshold of 5 cm/s, and an RI threshold of 1.0. Measurements of EDV, TAV, RI, and PI in patients with repeated unsatisfactory reactions on intracavernous prostaglandin injection are poor predictors of venous leakage and should not replace DPCC in the investigation of vasculogenic impotence.
引用
收藏
页码:35 / 41
页数:6
相关论文
共 50 条
  • [1] Venous incompetence in erectile dysfunction:: evaluation with color-coded duplex sonography and cavernosometry/-graphy
    Fürst, G
    Müller-Mattheis, V
    Cohnen, M
    Trautner, C
    Haastert, B
    Saleh, A
    Malms, J
    Ackermann, R
    Mödder, U
    EUROPEAN RADIOLOGY, 1999, 9 (01) : 35 - 41
  • [2] Evaluation of penile perfusion by color-coded duplex sonography in the management of erectile dysfunction
    Altinkilic, B
    Hauck, EW
    Weidner, W
    WORLD JOURNAL OF UROLOGY, 2004, 22 (05) : 361 - 364
  • [3] Evaluation of penile perfusion by color-coded duplex sonography in the management of erectile dysfunction
    Bora Altinkilic
    Ekkehard W. Hauck
    Wolfgang Weidner
    World Journal of Urology, 2004, 22 : 361 - 364
  • [4] The value of color-coded duplex sonography as standard procedure in erectile dysfunction
    Lehmann, K
    Kacl, G
    Hagspiel, K
    Hauri, D
    UROLOGE-AUSGABE A, 1996, 35 (06): : 456 - 461
  • [5] The value of color-coded duplex sonography as standard procedure in erectile dysfunction - Comment
    Weidner, W
    Stief, C
    UROLOGE A, 1996, 35 (06): : 461 - 462
  • [6] Transcranial color-coded duplex sonography
    Baumgartner, RW
    JOURNAL OF NEUROLOGY, 1999, 246 (08) : 637 - 647
  • [7] Transcranial color-coded duplex sonography
    Ralf W. Baumgartner
    Journal of Neurology, 1999, 246 : 637 - 647
  • [8] COLOR-CODED DUPLEX SONOGRAPHY (ANGIODYNOGRAPHY)
    MODDER, U
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (03): : 204 - 209
  • [9] Assessment of the penile vascular system with color-coded duplex sonography and pharmacocavernosometry and -graphy in impotent men
    Andresen, R
    Wegner, HEH
    ACTA RADIOLOGICA, 1997, 38 (02) : 303 - 308
  • [10] EVALUATION OF CEREBRAL ANEURYSMS WITH TRANSCRANIAL COLOR-CODED DUPLEX SONOGRAPHY
    BARTELS, E
    RODIEK, SO
    FLUGEL, KA
    STROKE, 1995, 26 (04) : 721 - 721