Determination of sources of error and improvement in accuracy of left ventricular mass measurement by echocardiography

被引:0
|
作者
Najmul Siddiqi
Sunil Vasireddi
Prasongchai Sattayaprasert
Ritu Thamman
Akhil Narang
Ashish Aneja
机构
[1] MetroHealth Campus of Case Western Reserve University,Heart and Vascular Center
[2] University of Pittsburgh,School of Medicine
[3] Northwestern University,Feinberg School of Medicine
关键词
Left ventricular mass; Echocardiography; Cardiac magnetic resonance imaging; Error;
D O I
暂无
中图分类号
学科分类号
摘要
Abnormal Left ventricular mass (LVM) prognosticates adverse cardiovascular events. Conventionally, LVM measured by echo assumes a prolate ellipsoid (PE) shape; however, it poorly correlates with reference standard of cardiac magnetic resonance imaging (CMR) derived LVM. PE model assumes LVL = 2 × LVID. We developed a new echo LVM formula based on LV length and tested for accuracy against CMR. A retrospective study of consecutive patients with an echocardiogram and CMR within 3 months. Derivation (n = 170) and validation cohorts (n = 54) were used to test the new formula. Following analysis of correlation of interventricular septum (IVS), LV internal dimension (LVID), posterior wall (PW) and LVL between echo and CMR, a novel paraboloid-shape linear regression (PLR) model was derived. LVM by both models were compared to CMR. Poor correlation observed between actual and assumed LVL (0.52 with CMR; 0.44 with echo). Strong correlation was noted between echo and CMR measured LVL, LVID, IVS (r > 0.80) and a moderate correlation with PW (r = 0.62). Strong correlation of LVL was harnessed to develop PLR model, which significantly decreased paired error in derivation cohort (from 64 ± 42 to 22 ± 21 gm) and validation cohort (from 63 ± 46 to 25 ± 18 gm). Furthermore, it demonstrates significant reduction in absolute, relative errors and variability along with superior correlation in both cohorts. Between echo and CMR, LVL demonstrates one of the best correlation among LV dimensions. The assumption, LVL = 2 × LVID appears inaccurate. PLR model incorporates LVL and significantly improves accuracy, reduces variability of LVM.
引用
收藏
页码:2129 / 2137
页数:8
相关论文
共 50 条
  • [1] Determination of sources of error and improvement in accuracy of left ventricular mass measurement by echocardiography
    Siddiqi, Najmul
    Vasireddi, Sunil
    Sattayaprasert, Prasongchai
    Thamman, Ritu
    Narang, Akhil
    Aneja, Ashish
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (10): : 2129 - 2137
  • [2] Editorial commentary for the manuscript entitled determination of sources of error and improvement in accuracy of left ventricular mass measurement by echocardiography
    Nursen Keles
    The International Journal of Cardiovascular Imaging, 2022, 38 : 2139 - 2140
  • [3] Editorial commentary for the manuscript entitled determination of sources of error and improvement in accuracy of left ventricular mass measurement by echocardiography
    Keles, Nursen
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (10): : 2139 - 2140
  • [4] Accuracy of the measurement of the left ventricular mass by contrast echocardiography in rats
    Hirata, K
    Kobayashi, H
    Hirayama, H
    Watanabe, H
    Teragaki, M
    Muro, T
    Takeuchi, K
    Yoshikawa, J
    Beppu, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 449A - 449A
  • [5] Influence of measurement inaccuracies on determination of left ventricular mass by M mode echocardiography
    Stollberger, C
    Hollander, I
    Dimitrov, L
    Slany, J
    HEART, 1996, 75 (03) : 312 - 313
  • [6] MEASUREMENT OF LEFT VENTRICULAR WALL THICKNESS AND MASS BY ECHOCARDIOGRAPHY
    TROY, BL
    RACKLEY, CE
    POMBO, J
    CIRCULATION, 1972, 45 (03) : 602 - &
  • [7] Meta-Analysis of Accuracy of Left Ventricular Mass Measurement by Three-Dimensional Echocardiography
    Shimada, Yuichi J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (03): : 445 - 452
  • [8] Several sources of error in estimation of left ventricular mass with M-mode echocardiography in elderly subjects
    Barbier, Charlotte Ebeling
    Johansson, Lars
    Lind, Lars
    Ahlstrom, Hakan
    Bjerner, Tomas
    UPSALA JOURNAL OF MEDICAL SCIENCES, 2011, 116 (04) : 258 - 264
  • [9] Determination of left ventricular mass by echocardiography in normotensive diabetic patients
    Hirayama, H
    Sugano, M
    Abe, N
    Yonemochi, H
    Makino, N
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (12): : 921 - 924
  • [10] Reference techniques for left ventricular volume measurement by three-dimensional echocardiography: Determination of precision, accuracy, and feasibility
    Belohlavek, M
    Foster, SM
    Kinnick, RR
    Greenleaf, JF
    Seward, JB
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (04): : 329 - 335