Validation of mid-infrared spectroscopy for continuous glucose monitoring: the manage II study

被引:0
|
作者
J-C Preiser
A Brasseur
D Fagnoul
J-L Vincent
机构
[1] Erasme University Hospital,Intensive Care
[2] Erasme University Hospital,undefined
关键词
Blood Glucose; Continuous Glucose Monitoring; Signed Informed Consent; Reference Sensor; Nursing Workload;
D O I
10.1186/2197-425X-3-S1-A294
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Continuous glucose monitoring by means of mid-infrared transmission laser spectroscopy in vitro
    Vrancic, Christian
    Fomichova, Anna
    Gretz, Norbert
    Herrmann, Carina
    Neudecker, Sabine
    Pucci, Annemarie
    Petrich, Wolfgang
    [J]. ANALYST, 2011, 136 (06) : 1192 - 1198
  • [2] Continuous glucose monitoring by means of fiber-based, mid-infrared laser spectroscopy
    Lambrecht, A.
    Beyer, T.
    Hebestreit, K.
    Mischler, R.
    Petrich, W.
    [J]. APPLIED SPECTROSCOPY, 2006, 60 (07) : 729 - 736
  • [3] ICU glucose monitoring measured in plasma using mid-infrared spectroscopy
    T Heise
    L Nosek
    J Gable
    G Lim
    C Calentine
    [J]. Critical Care, 14 (Suppl 1):
  • [4] Study on monitoring bacillus subtilis fermentation process by mid-infrared spectroscopy
    He, Zhonghai
    Wang, Xinpan
    Ma, Zhenhe
    [J]. ADVANCES IN COMPUTERS, ELECTRONICS AND MECHATRONICS, 2014, 667 : 368 - +
  • [5] Evaluation of Opportunities and Limitations of Mid-Infrared Skin Spectroscopy for Noninvasive Blood Glucose Monitoring
    Delbeck, Sven
    Heise, H. Michael
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (01): : 19 - 27
  • [6] Noninvasive glucose monitoring using mid-infrared absorption spectroscopy based on a few wavenumbers
    Kasahara, Ryosuke
    Kino, Saiko
    Soyama, Shunsuke
    Matsuura, Yuji
    [J]. BIOMEDICAL OPTICS EXPRESS, 2018, 9 (01): : 289 - 302
  • [7] Unsupervised calibration for noninvasive glucose-monitoring devices using mid-infrared spectroscopy
    Kasahara, Ryosuke
    Kino, Saiko
    Soyama, Shunsuke
    Matsuura, Yuji
    [J]. JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2018, 11 (06)
  • [8] On-line fermentation monitoring by mid-infrared spectroscopy
    Mazarevica, G
    Diewok, J
    Baena, JR
    Rosenberg, E
    Lendl, B
    [J]. APPLIED SPECTROSCOPY, 2004, 58 (07) : 804 - 810
  • [9] Continuous glucose determination using fiber-based tunable mid-infrared laser spectroscopy
    Yu, Songlin
    Li, Dachao
    Chong, Hao
    Sun, Changyue
    Xu, Kexin
    [J]. OPTICS AND LASERS IN ENGINEERING, 2014, 55 : 78 - 83
  • [10] In-vitro characteristics of a mid-infrared, continuous glucose sensor
    Herrmann, Carina
    Vrancic, Christian
    Fomichova, Anna
    Gretz, Norbert
    Hoecker, Sabine
    Pucci, Annemarie
    Petrich, Wolfgang
    [J]. BIOMEDICAL VIBRATIONAL SPECTROSCOPY IV: ADVANCES IN RESEARCH AND INDUSTRY, 2010, 7560