Does a replacement or revision of an inflatable penile prosthesis lead to decreased patient satisfaction?

被引:0
|
作者
A A Caire
A Boonjindasup
W J G Hellstrom
机构
[1] Tulane University School of Medicine,Department of Urology
关键词
ED; inflatable penile prosthesis; sexual satisfaction;
D O I
暂无
中图分类号
学科分类号
摘要
To analyze the reason for replacement, revision and overall satisfaction of a cohort who underwent surgical replacement of an inflatable penile prosthesis (IPP). A cohort of 105 patients who underwent IPP replacement from 2005–2007 was retrieved from the prosthesis database. Approximately 21.9% (23) underwent replacement or revision of their prosthesis because of complications, and were further analyzed. Reason for removal was stratified into infectious and non-infectious (erosion, non-function and patient discomfort). Age, race (African American vs non-African American), smoking history, hypertension, diabetes, coronary artery disease and hyperlipidemia were stratified by reason for removal. Finally, we contacted patients and recorded subjective satisfaction with their IPP. The reason for removal was most commonly because of a non-functional IPP (47.8%), followed by infection (30.4%), erosion (17.4%) and patient discomfort (4.3%). Age and race did not show a significant difference when analyzing reason for replacement (P>0.05). Patients who were smokers (P=0.907) had hypertension (P=0.554), diabetes (P=0.591) or hyperlipidemia (P=0.219) did not have significantly higher infection rates. Approximately 58.3% were satisfied with their prosthesis, 75% would have the surgery performed again and 91.7% would still recommend prosthesis surgery. Device malfunction was the primary reason for replacement/removal at our institution. Despite the complications of prosthesis reoperation, the majority of patients were still satisfied with their prosthesis, would have the surgery performed again and would recommend prosthesis surgery to a friend.
引用
收藏
页码:39 / 42
页数:3
相关论文
共 50 条
  • [1] Does a replacement or revision of an inflatable penile prosthesis lead to decreased patient satisfaction?
    Caire, A. A.
    Boonjindasup, A.
    Hellstrom, W. J. G.
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2011, 23 (02) : 39 - 42
  • [2] DOES A REPLACEMENT OR REVISION OF AN INFLATABLE PENILE PROSTHESIS LEAD TO DECREASED PATIENT SATISFACTION?
    Caire, A.
    Boondinjasup, A.
    Patel, K.
    Bernie, A.
    Johnsen, N.
    Hellstrom, W.
    JOURNAL OF SEXUAL MEDICINE, 2011, 8 : 42 - 42
  • [3] Re: Does a Replacement or Revision of an Inflatable Penile Prosthesis Lead to Decreased Patient Satisfaction? Editorial Comment
    Seftel, Allen D.
    JOURNAL OF UROLOGY, 2011, 186 (04): : 1409 - 1409
  • [4] DOES THE NEED FOR A REPLACEMENT INFLATABLE PENILE PROSTHESIS LEAD TO DECREASED PATIENT SATISFACTION?
    Caire, Arthur
    Boonjindasup, Aaron
    Richardson, Brian
    Hellstrom, Wayne
    JOURNAL OF UROLOGY, 2011, 185 (04): : E369 - E369
  • [5] PATIENT SATISFACTION WITH MENTOR INFLATABLE PENILE PROSTHESIS
    WHALEN, RK
    MERRILL, DC
    UROLOGY, 1991, 37 (06) : 531 - 539
  • [6] PATIENT-PARTNER SATISFACTION LEVELS WITH THE INFLATABLE PENILE PROSTHESIS
    FURLOW, WL
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1980, 243 (17): : 1714 - 1714
  • [7] A Review of Factors Affecting Patient Satisfaction With Inflatable Penile Prosthesis
    Shah, Tejash
    Wang, Run
    SEXUAL MEDICINE REVIEWS, 2021, 9 (02) : 350 - 357
  • [8] POSTOPERATIVE SATISFACTION WITH INFLATABLE PENILE PROSTHESIS
    Dinerman, Brian
    Nassau, Daniel
    Eid, Jean Francois
    JOURNAL OF UROLOGY, 2020, 203 : E580 - E580
  • [9] DOES PARTNER INVOLVEMENT AND EDUCATION IN INFLATABLE PENILE PROSTHESIS SURGERY INFLUENCE PATIENT SATISFACTION RATES?
    Magill, R.
    Mehr, J.
    Supak, T. G.
    Supak, D.
    Kim, D.
    Attia, M.
    Wang, R.
    JOURNAL OF SEXUAL MEDICINE, 2023, 20
  • [10] Modified salvage for inflatable penile prosthesis revision
    Lentz A.C.
    Carson III C.C.
    Current Sexual Health Reports, 2008, 5 (3) : 110 - 112