Aortic Aneurysm After Patch Aortoplasty For Coarctation: Analysis of Patch Size and Wall Growth

被引:0
|
作者
A. Al-Hroob
T.S. Husayni
A. Freter
P. Chiemmongkoltip
M.N. Ilbawi
R.A. Arcilla
机构
[1] Divisions of Cardiology and Cardiac Surgery,
[2] The Heart Institute for Children,undefined
[3] Hope Children's Hospital,undefined
[4] Advocate Christ Medical Center,undefined
[5] Oak Lawn,undefined
[6] IL,undefined
[7] University of Illinois at Chicago,undefined
[8] Chicago,undefined
[9] IL,undefined
来源
Pediatric Cardiology | 2003年 / 24卷
关键词
Aortic Aneurysm; Patch Size; Aortic Wall; Aorta Diameter; Aortic Dilatation;
D O I
暂无
中图分类号
学科分类号
摘要
Aortic aneurysm may develop after surgery for coarctation of aorta especially patch aortoplasty. The size of patch and of adjacent native aortic wall was analyzed to determine whether aortic dilatation represents a true aneurysm. Electron beam tomography (EBT) was done on 19 patients, three months to 17.5 years after patch aortoplasty. Tomograms of aorta were obtained in 6-mm slices, and maximal cross-sectional area was digitized to obtain: total circumference (Ct), patch component (Cp), and aortic wall component (Cw). Ct, Cp, and Cw were normalized to the circumference of distal aorta (Cda) as: isthmus/distal aorta (Ct/Cda), patch segment/distal aorta (Cp/Cda), wall segment/distal aorta (Cw/Cda). Ct/Cda ranged from 109% to 260%. In 12 patients (group A), it varied from 168% to 260%; and in seven (group B), 109% to 133%. There was strong correlation (r = 0.92) between Ct/Cda and Cp/Cda. Ct/Cda, Cp/Cda, and Cp/Cw were higher in group A than B (p <0.001) but Cw/Cda did not differ. Cw/Cda was greater than the coarctation/distal aorta diameter ratios of preoperative angiograms, consistent with accelerated aortic wall growth postsurgery. No definite aneurysm was seen. Localized dilatation of aorta following patch aortoplasty in children is primarily due to a large synthetic patch and, partly, to increased aortic wall growth. Serial EBT or magnetic resonance imaging is indicated to monitor aortic wall growth and occurrence of aneurysm.
引用
收藏
页码:10 / 16
页数:6
相关论文
共 50 条
  • [1] Aortic aneurysm after patch aortoplasty for coarctation: Analysis of patch size and wall growth
    Al-Hroob, A
    Husayni, TS
    Freter, A
    Chiemmongkoltip, P
    Ilbawi, MN
    Arcilla, RA
    [J]. PEDIATRIC CARDIOLOGY, 2003, 24 (01) : 10 - 16
  • [2] AORTIC-ANEURYSM AFTER PATCH AORTOPLASTY FOR COARCTATION IN CHILDHOOD
    RHEUBAN, KS
    CARPENTER, MA
    JEDEIKIN, R
    DAMMANN, JF
    ALFORD, BA
    KRON, IL
    GUTGESELL, HP
    NOLAN, SP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (05): : 612 - 612
  • [3] Aortic aneurysm after patch aortoplasty for coarctation of aorta: Is it real?
    Al Hroob, A
    Husayni, T
    Chiemmongkoltip, P
    Arcilla, R
    Ilbawi, M
    [J]. PEDIATRIC RESEARCH, 1999, 45 (04) : 18A - 18A
  • [4] Aortic Aneurysm after Patch Aortoplasty for Coarctation of Aorta: Is It Real?
    Assad Al Hroob
    Tarek Husayni
    Pipit Chiemmongkoltip
    Rene Arcilla
    Michel Ilbawi
    [J]. Pediatric Research, 1999, 45 (7) : 18 - 18
  • [5] Giant aneurysm - 25 years after patch aortoplasty for aortic coarctation
    Chiesa, Roberto
    Melissano, Germano
    Civilini, Efrem
    Bertoglio, Luca
    Setacci, Francesco
    Baccellieri, Domenico
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2008, 35 (02) : 220 - 221
  • [6] Aortic aneurysm formation following coarctation repair by Dacron patch aortoplasty
    Walhout, R. J.
    Braam, R. L.
    Schepens, M. A.
    Mulder, B. J. M.
    Plokker, H. W. M.
    [J]. NETHERLANDS HEART JOURNAL, 2010, 18 (7-8): : 376 - 377
  • [7] Aortic aneurysm formation following coarctation repair by Dacron patch aortoplasty
    R. J. Walhout
    R. L. Braam
    M. A. Schepens
    B. J. M. Mulder
    H. W. M. Plokker
    [J]. Netherlands Heart Journal, 2010, 18 : 376 - 377
  • [8] GROWTH OF THE AORTA AFTER PROSTHETIC PATCH AORTOPLASTY FOR COARCTATION IN INFANTS
    SADE, RM
    CRAWFORD, FA
    HOHN, AR
    RIOPEL, DA
    TAYLOR, AB
    [J]. ANNALS OF THORACIC SURGERY, 1984, 38 (01): : 21 - 25
  • [9] Pseudoaneurysm and aortobronchial fistula - after aortic coarctation repair by patch aortoplasty
    Posacioglu, H
    Apaydin, AZ
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2004, 31 (03): : 319 - 321
  • [10] AORTIC-ANEURYSM AFTER PATCH AORTOPLASTY REPAIR OF COARCTATION - A PROSPECTIVE ANALYSIS OF PREVALENCE, SCREENING-TESTS AND RISKS
    BROMBERG, BI
    BEEKMAN, RH
    ROCCHINI, AP
    SNIDER, AR
    BANK, ER
    HEIDELBERGER, K
    ROSENTHAL, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) : 734 - 741