Removal of ciprofloxacin from aqueous solution by a continuous flow electro-coagulation process

被引:0
|
作者
Jalal Basiri Parsa
Taher Mehdi Panah
Farideh Nabizadeh Chianeh
机构
[1] University of Bu-Ali Sina,Department of Applied Chemistry, Faculty of chemistry
来源
关键词
Electro-coagulation; Ciprofloxacin; Response Surface Methodology; Continuous Flow Process;
D O I
暂无
中图分类号
学科分类号
摘要
This study deals with the performance and modeling of the electro-coagulation process for ciprofloxacin (CIP) removal by using aluminum electrode as anode in a continuous electrochemical reactor. The initial pH, temperature, current density, time and flow rate were selected as independent variables in response surface methodology (RSM) involving a five-level central composite design (CCD), while CIP removal efficiency was considered as the response function. The result of optimization showed that the maximum amount of CIP removal efficiency (88%) presented at the optimal condition of pH=5.6, t=100min, T=25.5 °C, I=5.6mA/cm2 and V=25.9 mL/min. In addition, the mineralization of the CIP was investigated by chemical oxygen demand (COD) and total organic carbon (TOC) measurements that showed 77% COD removal and 49%TOC removal.
引用
收藏
页码:893 / 901
页数:8
相关论文
共 50 条
  • [1] Removal of ciprofloxacin from aqueous solution by a continuous flow electro-coagulation process
    Parsa, Jalal Basiri
    Panah, Taher Mehdi
    Chianeh, Farideh Nabizadeh
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2016, 33 (03) : 893 - 901
  • [2] Removal of phosphate from aqueous solutions by electro-coagulation
    Bektas, N
    Akbulut, H
    Inan, H
    Dimoglo, A
    JOURNAL OF HAZARDOUS MATERIALS, 2004, 106 (2-3) : 101 - 105
  • [3] Removal of Arsenic(V) by electro-coagulation process
    Hernandez, J. R.
    Nava, J. L.
    Carreno, G.
    Martinez, F.
    WATER-ROCK INTERACTION (WRI-13), 2010, : 583 - 585
  • [4] Removal of Arsenate from Aqueous Solution by Electro-Coagulation Method Using Al-Fe Electrodes
    Ali, Imran
    Gupta, Vinod K.
    Khan, Tabrez A.
    Asim, Mohd
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 1898 - 1907
  • [5] Removal of arsenite by simultaneous electro-oxidation and electro-coagulation process
    Zhao, Xu
    Zhang, Baofeng
    Liu, Huijuan
    Qu, Jiuhui
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 184 (1-3) : 472 - 476
  • [6] Techno-economical evaluation of nitrate removal using continuous flow electro-coagulation process: optimization by Taguchi model
    Niaragh, E. Karamati
    Moghaddam, M. R. Alavi
    Emamjomeh, M. M.
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2017, 17 (06): : 1703 - 1711
  • [7] Phosphonate removal from membrane concentrate by electro-coagulation
    Serrano, Victor Manuel Torres
    Eshun, Lordina Ekua
    Farinha, Andreia
    Witkamp, Geert-Jan
    Bucs, Szilard
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2022, 10 (06):
  • [8] APPLICATION OF COAGULATION AND ELECTRO-COAGULATION METHODS FOR REMOVAL OF PHOSPHATE FROM WASTEWATER
    Jasim, Nidaa Adil
    Hussein, Tamara Kawther
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2021, 16 (06): : 4600 - 4611
  • [9] The Removal of Arsenic Ion in Electro-Coagulation Cell
    Ji, Sangwoo
    Dempsey, Brian A.
    Yoo, Kyoungkeun
    GEOSYSTEM ENGINEERING, 2011, 14 (02) : 71 - 78
  • [10] Removal of bentonite causing turbidity by electro-coagulation
    Abuzaid, NS
    Bukhari, AA
    Al-Hamouz, ZM
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 1998, 33 (07): : 1341 - 1358