Identification of a Non-Linear Model as a New Method to Detect Expiratory Airflow Limitation in Mechanically Ventilated Patients

被引:0
|
作者
S. Khirani
L. Biot
P. Lavagne
A. Duguet
T. Similowski
P. Baconnier
机构
[1] Université,Equipe de Physiologie Respiratoire Expérimentale, Théorique et Appliquée, Laboratoire TIMC/IMAG, Faculté de Médecine de Grenoble
[2] Centre Hospitalier Lyon Sud,Département d'Anesthésie
[3] chemin de Grand Revoyet,Réanimation
[4] Département d'Anesthésie-Réanimation II,Unité de Réanimation Chirurgicale
[5] Centre Hospitalier de la Pitié Salpetrière,Service de pneumologie et de réanimation
[6] Université ParisVI Pierre et Marie Curie,UPRES EA 2397
来源
Acta Biotheoretica | 2004年 / 52卷
关键词
expiratory flow limitation; mathematical model; ventilatory assistance; PEEP; human beings;
D O I
暂无
中图分类号
学科分类号
摘要
Expiratory flow limitation (EFL) can occur in mechanically ventilated patients with chronic obstructive pulmonary disease and other disorders. It leads to dynamic hyperinflation with ensuing deleterious consequences. Detecting EFL is thus clinically relevant. Easily applicable methods however lack this detection being routinely made in intensive care. Using a simple mathematical model, we propose a new method to detect EFL that does not require any intervention or modification of the ongoing therapeutic. The model consists in a monoalveolar representation of the respiratory system, including a collapsible airway that is submitted to periodic changes in pressure at the airway opening: EFL provokes a sharp expiratory increase in the resistance Rc of the collapsible airway. The model parameters were identified via the Levenberg-Marquardt method by fitting simulated data on the airway pressure and the flow signals recorded in 10 mechanically ventilated patients. A sensitivity study demonstrated that only 8/11 parameters needed to be identified, the remaining three being given reasonable physiological values. Flow-volume curves built at different levels of positive expiratory pressure, PEEP, during “PEEP trials” (stepwise increases in positive end-expiratory pressure to optimize ventilator settings) have shown evidence of EFL in three cases. This was concordant with parameter identification (high Rc during expiration for EFL patients). We conclude from these preliminary results that our model is a potential tool for the non-invasive detection of EFL in mechanically ventilated patients.
引用
收藏
页码:241 / 254
页数:13
相关论文
共 50 条
  • [1] Identification of a non-linear model as a new method to detect expiratory airflow limitation in mechanically ventilated patients
    Khirani, S
    Biot, L
    Lavagne, P
    Duguet, A
    Similowski, T
    Baconnier, P
    ACTA BIOTHEORETICA, 2004, 52 (04) : 241 - 254
  • [2] CLINICAL CONSEQUENCES OF EXPIRATORY FLOW LIMITATION IN MECHANICALLY VENTILATED PATIENTS
    Armaganidis, A.
    Stavrakaki-Kallergi, K.
    Sotiropoulou, C.
    Koutsoukou, A.
    Milic-Emili, J.
    Roussos, C.
    INTENSIVE CARE MEDICINE, 2009, 35 : 22 - 22
  • [3] Expiratory flow limitation in mechanically ventilated patients: a simulation study
    Brighenti, C
    Gnudi, G
    Cevenini, G
    Barbini, P
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 411 - 414
  • [4] Expiratory flow limitation in morbidly obese postoperative mechanically ventilated patients
    Koutsoukou, A
    Koulouris, N
    Bekos, B
    Sotiropoulou, C
    Kosmas, E
    Papadima, K
    Roussos, C
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (09) : 1080 - 1088
  • [5] INFLUENCE OF BODY POSTURE AND BRONCHODILATION ON EXPIRATORY FLOW LIMITATION IN MECHANICALLY VENTILATED PATIENTS
    Stavrakaki-Kallergi, K.
    Koutsoukou, A.
    Sotiropoulou, C.
    Roussos, C.
    Milic-Emili, J.
    Armaganidis, A.
    INTENSIVE CARE MEDICINE, 2009, 35 : 53 - 53
  • [6] Intrinsic positive end-expiratory pressure in mechanically ventilated patients with and without tidal expiratory flow limitation
    Armaganidis, A
    Stavrakaki-Kallergi, K
    Koutsoukou, A
    Lymberis, A
    Milic-Emili, J
    Roussos, C
    CRITICAL CARE MEDICINE, 2000, 28 (12) : 3837 - 3842
  • [7] Estimating the incidence of spontaneous breathing effort of mechanically ventilated patients using a non-linear auto regressive (NARX) model
    Zainol, Nurhidayah Mohd
    Damanhuri, Nor Salwa
    Othman, Nor Azlan
    Chiew, Yeong Shiong
    Nor, Mohd Basri Mat
    Muhammad, Zuraida
    Chase, J. Geoffrey
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 220
  • [8] A new method of communication in mechanically ventilated patients
    Vanden Boogaard, M
    Van Grunsven, A
    INTENSIVE CARE MEDICINE, 2003, 29 : S60 - S60
  • [9] Repurposing catheter ablation work-up to detect expiratory airflow limitation in patients with atrial fibrillation
    Hereijgers, Maartje J. M.
    van der Velden, Rachel M. J.
    el Moussaoui, Nora
    Verhaert, Dominique V. M.
    Habibi, Zarina
    Luermans, Justin
    den Uijl, Dennis
    Chaldoupi, Sevasti-Maria
    Vernooy, Kevin
    Schotten, Ulrich
    Baumert, Mathias
    Gietema, Hester A.
    Mihl, Casper
    Koltowski, Lukasz
    Franssen, Frits M. E.
    Simons, Sami O.
    Linz, Dominik
    IJC HEART & VASCULATURE, 2023, 49
  • [10] A NEW NON-LINEAR SUPERCAPACITOR EMBEDDED MODEL AND ITS ONLINE TIME IDENTIFICATION METHOD
    Bertrand, Nicolas
    Sabatier, Jocelyn
    Vinassa, Jean-Michel
    Briat, Oliver
    PROCEEDINGS OF ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, VOL 4, PTS A-C, 2010, : 1233 - 1240