Monitoring the Thermal Stress State in Steam Turbines

被引:4
|
作者
Radin Y.A. [1 ]
Kontorovich T.S. [1 ]
Golov P.V. [1 ]
机构
[1] PJSC “Mosenergo,”, Moscow
关键词
algorithm; control valve; equivalent operating hours; maintenance operations; monitoring; rotor; service life; software program; steam turbine; stop valve; thermal stress state;
D O I
10.1007/s10749-020-01146-6
中图分类号
学科分类号
摘要
The principles of a program for monitoring stresses in rotors and bodies of stop and control valves of nonreheat steam turbines of up to 180 MW capacity to control the startup processes are formulated. The program based on the experimental data obtained by the VTI and ORGRES and calculated results obtained with the finite-element method is intended for microcomputers with hardware integrated into the electronics of the control system or the automatic process control system. Using the data from the regular control and measuring instruments, the program estimates the stresses in the “critical” elements of the steam turbine, compares them with the level permissible for the material, depending on the operating temperatures, service life, design and other parameters, and generates signals to adjust the startup process. The equivalent operating hours can also be calculated to assess the quality of startups and shutdown processes, accumulated damage, and relative past life. These data can be taken into account when deciding on maintenance operations. The algorithm of the stress monitoring system is implemented in the program limiting the rate of spinup and power change from the thermal stress state of the rotors of the high- and intermediate-pressure cylinders of the T-185/210 – 16.0 turbine. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.
引用
收藏
页码:719 / 723
页数:4
相关论文
共 50 条
  • [1] Thermal stress monitoring in steam turbines
    Sindelár, R
    Toewe, W
    BRENNSTOFF-WARME-KRAFT, 1999, 51 (10): : 46 - +
  • [2] Rotor thermal stress monitoring in steam turbines
    Antonin, Bouberle
    Jan, Jakl
    Jindrich, Liska
    12TH EUROPEAN WORKSHOP ON ADVANCED CONTROL AND DIAGNOSIS (ACD 2015), 2015, 659
  • [3] TENSOMAX - a retrofit thermal stress monitoring system for steam turbines
    Sindelär, R.
    Toewe, W.
    VGB PowerTech, 2000, 80 (01): : 41 - 43
  • [4] Efficient NMPC strategies for thermal stress control of steam turbines
    Garrucciu, Vittoria
    di Capaci, Riccardo Bacci
    Vaccari, Marco
    Manara, Silvia
    Bucciarelli, Federico
    Signorini, Annamaria
    Pannocchia, Gabriele
    IFAC PAPERSONLINE, 2024, 58 (18): : 29 - 34
  • [5] Monitoring of Steam Turbines.
    Sindelar, Rudolf
    Brennstoff-Waerme-Kraft, 1978, 30 (05): : 207 - 214
  • [6] Operational diagnostics of thermal state and efficiency of steam turbines of TPP and NPP
    Bozhko V.V.
    Kovalenko A.N.
    Lyapunov V.M.
    Khomenok L.A.
    Thermal Engineering, 2016, 63 (5) : 349 - 354
  • [7] DEVELOPMENT OF STATE OF THE ART DYNAMIC STRESS PREDICTION METHODOLOGY FOR STEAM TURBINES
    Chen, Tie
    Rogerson, John
    Yang, Fang
    Singh, Gurnam
    Hemsley, Phil
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 6, PTS A AND B, 2012, : 113 - 120
  • [8] THERMAL REGENERATION OF STEAM LINES TO TURBINES
    ANTIKAIN, PA
    ENERGIETECHNIK, 1980, 30 (05): : 181 - 184
  • [9] OPERATION AND MAINTENANCE IMPROVEMENTS OF STEAM TURBINES SUBJECT TO FREQUENT START BY ROTOR STRESS MONITORING
    Bucciarelli, Federico
    Checcacci, Damaso
    Girezzi, Gabriele
    Signorini, Annamaria
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 9, 2020,
  • [10] Thermal Regeneration of Steam Lines to Turbines.
    Antikain, Piotr A.
    Energietechnik Leipzig, 1980, 30 (05): : 181 - 184